Automatic Cardiac Self-Gating of Small-Animal PET Data.

Joaquin L Herraiz1,2, Elena Herranz3,4, Jacobo Cal-González5, Juan J Vaquero6,7, Manuel Desco6,7,8, Lorena Cussó6,7,8, Jose M Udias9.   

Abstract

PURPOSE: The cardiac gating signal (CGS) in positron emission tomography (PET) studies is usually obtained from an electrocardiography (ECG) monitor. In this work, we propose a method to obtain the CGS in small-animal PET using the acquired list-mode data without using any hardware or end-user input. PROCEDURES: The CGS was obtained from the number of coincidences over time acquired in the lines-of-response connected with the cardiac region. This region is identified in the image as its value changes with frequencies in the range of 3 to 12 Hz. The procedure was tested in a study with 29 Wistar rats and 6 mice injected with 2-deoxy-2-[(18)F]fluoro-D-glucose, which underwent a 45-min single-bed list-mode PET scan of the heart syncronized with an ECG. The estimated signals and the reconstructed images using eight-gated frames were compared with the ones obtained using the ECG signal from the monitor.
RESULTS: The differences of the PET-based CGS with respect to the ECG relative to the duration of the heartbeats were 5.6 % in rats and 11.0 % in mice. The reconstructed gated images obtained from the proposed method do not differ qualitatively with respect to the ones obtained with the ECG. The quantitative analysis of both set of images were performed measuring the volume of the left ventricle (LV) of the rats in the end-of-systole and end-of-diastole phase. The differences found in these parameters between both methods were below 12.1 % in the ESV and 9.3 % in the EDV with a 95 % confidence interval, which are comparable to the accuracy (7 %) of the method used for segmenting the LV.
CONCLUSION: The proposed method is able to provide a valid and accurate CGS in small-animal PET list-mode data.

Entities:  

Keywords:  Cardiac gating; List-mode; PET; Self-gating; Small animal

Mesh:

Year:  2016        PMID: 26054381     DOI: 10.1007/s11307-015-0868-y

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  13 in total

1.  Quantitative gated PET for the assessment of left ventricular function in small animals.

Authors:  Etienne Croteau; François Bénard; Jules Cadorette; Marie-Eve Gauthier; Antonio Aliaga; M'hamed Bentourkia; Roger Lecomte
Journal:  J Nucl Med       Date:  2003-10       Impact factor: 10.057

2.  A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

Authors:  Adam Leon Kesner; Claudia Kuntner
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  FIRST: Fast Iterative Reconstruction Software for (PET) tomography.

Authors:  J L Herraiz; S España; J J Vaquero; M Desco; J M Udías
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

4.  Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents.

Authors:  Guido Böning; Andrei Todica; Alessandro Vai; Sebastian Lehner; Guoming Xiong; Erik Mille; Harun Ilhan; Christian la Fougère; Peter Bartenstein; Marcus Hacker
Journal:  Phys Med Biol       Date:  2013-10-29       Impact factor: 3.609

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Fast calculation of the exact radiological path for a three-dimensional CT array.

Authors:  R L Siddon
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

7.  Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.

Authors:  Yuchuan Wang; Jurgen Seidel; Benjamin M W Tsui; Juan J Vaquero; Martin G Pomper
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

8.  Positron emission tomography imaging of cardiac reporter gene expression in living rats.

Authors:  Joseph C Wu; Masayuki Inubushi; Gobalakrishnan Sundaresan; Heinrich R Schelbert; Sanjiv S Gambhir
Journal:  Circulation       Date:  2002-07-09       Impact factor: 29.690

9.  List mode-driven cardiac and respiratory gating in PET.

Authors:  Florian Büther; Mohammad Dawood; Lars Stegger; Frank Wübbeling; Michael Schäfers; Otmar Schober; Klaus P Schäfers
Journal:  J Nucl Med       Date:  2009-04-16       Impact factor: 10.057

10.  4D-PET data sorting into different number of phases: a NEMA IQ phantom study.

Authors:  Pietro Mancosu; Roberto Sghedoni; Valentino Bettinardi; Federica Fioroni; Mark Anthony Aquilina; Elisa Grassi; Ferruccio Fazio; Giovanni Borasi; Maria Carla Gilardi
Journal:  J Appl Clin Med Phys       Date:  2009-10-28       Impact factor: 2.102

View more
  2 in total

Review 1.  Advances in Preclinical PET.

Authors:  Stephen S Adler; Jurgen Seidel; Peter L Choyke
Journal:  Semin Nucl Med       Date:  2022-03-18       Impact factor: 4.802

2.  Image-Derived Input Functions for Quantification of A1 Adenosine Receptors Availability in Mice Brains Using PET and [18F]CPFPX.

Authors:  Xuan He; Franziska Wedekind; Tina Kroll; Angela Oskamp; Simone Beer; Alexander Drzezga; Johannes Ermert; Bernd Neumaier; Andreas Bauer; David Elmenhorst
Journal:  Front Physiol       Date:  2020-01-29       Impact factor: 4.566

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.