Literature DB >> 26051868

Heat generation and drill wear during dental implant site preparation: systematic review.

S C Möhlhenrich1, A Modabber2, T Steiner2, D A Mitchell3, F Hölzle2.   

Abstract

To identify factors that minimise damage during the drilling of sites for dental implants, we reviewed published papers on the amount of heat that is generated. We systematically searched English language studies published between January 2000 and February 2014 on MEDLINE/PubMed and found 41 articles, of which 27 related to an increase in temperature during preparation of the site. We found only basic research with a low level of evidence. Most of the studies were in vitro, and osteotomies were usually made in non-vital bone from cows or pigs. To measure heat in real time, thermocouples were used in 18 studies and infrared thermographs in 7. Three studies reported the use of immunohistochemical analysis to investigate immediate viability of cells. The highest temperature measured was 64.4°C and the lowest 28.4°C. Drill wear was reported after preparation of 50 sites, and there was a significant increase in temperature and a small change in the physiological balance of the proteins in the bone cells. Differences in the study designs meant that meta-analysis was not appropriate. For future work, we recommend the use of standard variables: an axial load of 2kg, drilling speed of 1500rpm, irrigation, standard artificial bone blocks, and the use of infrared thermography.
Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Heat generation; Implant site preparation; Infrared thermography; Irrigation methods; Osseous models; Thermocouple

Mesh:

Substances:

Year:  2015        PMID: 26051868     DOI: 10.1016/j.bjoms.2015.05.004

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  21 in total

Review 1.  Removal of osseointegrated dental implants: a systematic review of explantation techniques.

Authors:  Margaux Roy; Lucie Loutan; Giovanni Garavaglia; Dena Hashim
Journal:  Clin Oral Investig       Date:  2019-11-15       Impact factor: 3.573

2.  Comparison of Maximum Heat Generation during Implant Site Preparation between Single and Gradual Drilling Protocols in Artificial D1 Bone Blocks: An In Vitro Study.

Authors:  Tammam Koutiech; Omar Ahmad Heshmeh; Kamal Alkerdi; Johnny Toumi; Laith Al Sabek
Journal:  Int J Dent       Date:  2022-06-18

3.  Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study.

Authors:  Stephan Christian Möhlhenrich; Mustapha Abouridouane; Nicole Heussen; Ali Modabber; Fritz Klocke; Frank Hölzle
Journal:  Oral Maxillofac Surg       Date:  2015-11-20

Review 4.  Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review.

Authors:  Juan Carlos Bernabeu-Mira; David Soto-Peñaloza; Miguel Peñarrocha-Diago; Fabio Camacho-Alonso; Rebeca Rivas-Ballester; David Peñarrocha-Oltra
Journal:  Clin Oral Investig       Date:  2021-04-24       Impact factor: 3.573

Review 5.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

6.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

7.  Application of Propolis in Protecting Skeletal and Periodontal Health-A Systematic Review.

Authors:  Sophia Ogechi Ekeuku; Kok-Yong Chin
Journal:  Molecules       Date:  2021-05-25       Impact factor: 4.411

8.  Infrared Thermographic Assessment of Cooling Effectiveness in Selected Dental Implant Systems.

Authors:  Karol Kirstein; Maciej Dobrzyński; Piotr Kosior; Aleksander Chrószcz; Krzysztof Dudek; Katarzyna Fita; Olga Parulska; Zbigniew Rybak; Aleksandra Skalec; Magdalena Szklarz; Maciej Janeczek
Journal:  Biomed Res Int       Date:  2016-03-15       Impact factor: 3.411

9.  Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation.

Authors:  H Pellicer-Chover; D Peñarrocha-Oltra; A Aloy-Prosper; J-C Sanchis-Gonzalez; M-A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-11-01

10.  Do increased drilling speed and depth affect bone viability at implant site?

Authors:  Reza Tabrizi; Ali Dehghani Nazhvanai; Mohammad Mahdi Farahmand; Sara Yasour Pourali; Sepanta Hosseinpour
Journal:  Dent Res J (Isfahan)       Date:  2017 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.