Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision.

Deric W de Wit1, Jose Diaz1, Tara C B Moore1, Salissou Moutari1, Jonathan E Moore2.   

Abstract

PURPOSE: To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality.
SETTING: Cathedral Eye Clinic, Belfast, United Kingdom.
DESIGN: Retrospective comparative case series.
METHODS: Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal near-segment placement and the other, superotemporal near-segment placement. A +3.00 diopter (D) reading addition (add) was used in all eyes. The main outcome measures included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), contrast sensitivity, and quality of vision. Follow-up was 3 months.
RESULTS: Patients ranged in age from 43 to 76 years. The inferonasal group comprised 80 eyes (40 patients) and the superotemporal group, 76 eyes (38 patients). The mean 3-month spherical equivalent was -0.11 D ± 0.49 (SD) in the inferonasal group and -0.18 ± 0.46 D in the superotemporal group. The mean postoperative UDVA was 0.14 ± 0.10 logMAR and 0.18 ± 0.15 logMAR, respectively. The mean monocular UNVA was 0.21 ± 0.14 logRAD and 0.24 ± 0.13 logRAD, respectively. No significant differences were observed in the higher-order aberrations, total Strehl ratio (point-spread function), or modulation transfer function between the groups. Dysphotopic symptoms measured with a validated quality-of-vision questionnaire were not significantly different between groups.
CONCLUSION: Positioning of the near add did not significantly affect objective or subjective visual function parameters.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26049829     DOI: 10.1016/j.jcrs.2014.07.045

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Binocular visual function after unilateral versus bilateral implantation of segmented refractive multifocal intraocular lenses: a pilot study.

Authors:  Yiyun Liu; Qianqian Lan; Tong Sun; Chuhao Tang; Tingting Yang; Hongyu Duan; Rongjun Liu; Hong Qi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-11-26       Impact factor: 3.117

2.  Secondary positioning of rotationally asymmetric refractive multifocal intraocular lens in a patient with glaucoma: A case report.

Authors:  Cong Fan; Yi Zhou; Jian Jiang
Journal:  World J Clin Cases       Date:  2022-07-16       Impact factor: 1.534

3.  One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition.

Authors:  Tetsuro Oshika; Hiroyuki Arai; Yoshifumi Fujita; Mikio Inamura; Yasushi Inoue; Toru Noda; Kazunori Miyata
Journal:  Sci Rep       Date:  2019-09-11       Impact factor: 4.379

4.  Prospective assessment of plate-haptic rotationally asymmetric multifocal toric intraocular lens with near addition of + 1.5 diopters.

Authors:  Tetsuro Oshika; Kazuno Negishi; Toru Noda; Hiroyuki Arai; Mikio Inamura; Yasushi Inoue; Teruyuki Miyoshi; Yoshifumi Fujita; Kazunori Miyata; Yumi Hasegawa
Journal:  BMC Ophthalmol       Date:  2020-11-18       Impact factor: 2.209