Endovascular Recanalization in Acute Ischemic Stroke Using the Solitaire FR Revascularization Device with Adjunctive C-Arm CT Imaging.

B D Mitchell1, P Chinnadurai2, G Chintalapani2, H A Morsi3, H Shaltoni3, M E Mawad3.   

Abstract

In this clinical report, we examined a single-center experience by using the Solitaire FR Revascularization Device in the treatment of acute ischemic stroke in which there was poor initial visualization of the occluded arterial branches by using biplanar cerebral angiography. In all cases, adjunctive C-arm CT was used during the deployment of the thrombectomy device to gain additional information regarding device placement and expansion. Outcome measures included the extent of reperfusion, posttreatment changes in NIHSS scores, posttreatment TICI scores, cerebral hemorrhage, and survival. Clot removal with successful arterial recanalization was achieved in 15/18 cases (83.3%) with TICI scores of 2b/3 in all patients who had initial recanalization. The NIHSS score improved, on average, from 19 pretreatment to 11 posttreatment, and 72% of patients survived. In cases of acute stroke in which there is little information available regarding the positioning and deployment of a retrievable stent during mechanical thrombectomy, the use of C-arm CT may provide more information about device placement across an area of thrombus.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2015        PMID: 26045574      PMCID: PMC7965275          DOI: 10.3174/ajnr.A4256

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  9 in total

1.  Cerebral CT perfusion using an interventional C-arm imaging system: cerebral blood flow measurements.

Authors:  A Ganguly; A Fieselmann; M Marks; J Rosenberg; J Boese; Y Deuerling-Zheng; M Straka; G Zaharchuk; R Bammer; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

2.  Flat panel detector computed tomography for the interaction between contrast-enhanced thrombi and stent retrievers in stroke therapy: a pilot study.

Authors:  K J Wenger; J Berkefeld; M Wagner
Journal:  Clin Neuroradiol       Date:  2013-08-15       Impact factor: 3.649

Review 3.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology.

Authors:  Mudassar Kamran; Sanjoy Nagaraja; James V Byrne
Journal:  Neuroradiology       Date:  2009-10-27       Impact factor: 2.804

4.  In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging.

Authors:  A Ganguly; A Fieselmann; J Boese; C Rohkohl; J Hornegger; R Fahrig
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial.

Authors:  Jeffrey L Saver; Reza Jahan; Elad I Levy; Tudor G Jovin; Blaise Baxter; Raul G Nogueira; Wayne Clark; Ronald Budzik; Osama O Zaidat
Journal:  Lancet       Date:  2012-08-26       Impact factor: 79.321

6.  Endovascular treatment of acute intracerebral artery occlusions with the solitaire stent: single-centre experience with 108 recanalization procedures.

Authors:  F Dorn; S Stehle; H Lockau; C Zimmer; T Liebig
Journal:  Cerebrovasc Dis       Date:  2012-06-30       Impact factor: 2.762

7.  Trevo versus solitaire a head-to-head comparison between two heavy weights of clot retrieval.

Authors:  Nuno Mendonça; Alan Flores; Jorge Pagola; Marta Rubiera; David Rodríguez-Luna; M Angels De Miquel; Pere Cardona; Helena Quesada; Paloma Mora; José Alvarez-Sabín; Carlos Molina; Marc Ribó
Journal:  J Neuroimaging       Date:  2012-08-22       Impact factor: 2.486

8.  SOLITAIRE™ with the intention for thrombectomy (SWIFT) trial: design of a randomized, controlled, multicenter study comparing the SOLITAIRE™ Flow Restoration device and the MERCI Retriever in acute ischaemic stroke.

Authors:  J L Saver; R Jahan; E I Levy; T G Jovin; B Baxter; R Nogueira; W Clark; R Budzik; O O Zaidat
Journal:  Int J Stroke       Date:  2012-11-06       Impact factor: 5.266

9.  Safety and efficacy of mechanical thrombectomy with solitaire stent retrieval for acute ischemic stroke: a systematic review.

Authors:  Jun Seok Koh; Sun Joo Lee; Chang-Woo Ryu; Ho Sung Kim
Journal:  Neurointervention       Date:  2012-02-29
  9 in total
  2 in total

1.  Fatal arterial rupture during angioplasty of a flow diverter in a recurrent, previously Y-stented giant MCA bifurcation aneurysm.

Authors:  Jean-Christophe Gentric; Robert Fahed; Tim E Darsaut; Igor Salazkin; Daniel Roy; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2016-02-17       Impact factor: 1.610

2.  Quantitative assessment of device-clot interaction for stent retriever thrombectomy.

Authors:  Kajo van der Marel; Ju-Yu Chueh; Olivia W Brooks; Robert M King; Miklos G Marosfoi; Erin T Langan; Sarena L Carniato; Matthew J Gounis; Raul G Nogueira; Ajit S Puri
Journal:  J Neurointerv Surg       Date:  2016-02-01       Impact factor: 5.836

  2 in total