Yuki Otani1, Takayuki Nose2, Takushi Dokiya3, Toshiaki Saeki4, Yu Kumazaki5, Shuuji Asahi6, Iwao Tsukiyama7, Ichirou Fukuda8, Hiroshi Sekine9, Naoto Shikama5, Takao Takahashi4, Ken Yoshida10, Tadayuki Kotsuma11, Norikazu Masuda12, Eisaku Yoden13, Kazutaka Nakashima14, Taisei Matsumura15, Shino Nakagawa16, Seiji Tachiiri17, Yoshio Moriguchi18, Jun Itami19, Masahiko Oguchi20.
Abstract
BACKGROUND: In Japan, breast-conserving surgery with closed cavity has generally been performed for breast cancer patients, and accelerated partial breast irradiation (APBI) is considered difficult because Asian females generally have smaller breast sizes than Western females. Therefore, common identification of target and treatment plan method in APBI is required. A prospective multicenter study was conducted in Japan to determine institutional compliance with APBI using high-dose-rate interstitial brachytherapy (ISBT) designed for Japanese female patients.Entities:
Mesh:
Year: 2015 PMID: 26040632 PMCID: PMC4461989 DOI: 10.1186/s13014-015-0430-8
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Fig. 1Clinical target volume (CTV) defines method
Patient demographics
| Variable | Mean ± SD (Range) | N (%) |
|---|---|---|
| Weight (kg) | 60 ± 11 (43 – 96) | |
| Height (cm) | 155 ± 6 (140 – 170) | |
| Body Mass Index | 25.0 ± 4.8 (18.4 – 41.6) | |
| Number of catheters (n) | 15 ± 3 (8 – 21) | |
| Breast excision weight (g) | 82 ± 44 (25 – 234) | |
| Volume of CTV (cm3) | 67 ± 29 (26 – 133) | |
| Bra size | ||
| A cup | 10 (22) | |
| B cup | 14 (30) | |
| C cup | 11 (24) | |
| ≥ D cup | 11 (24) |
Index parameters of the treatment plan
| Variable | Mean ± SD (Range) |
|---|---|
| Vref (cm3) | 117 ± 56 (40 – 282) |
| DNR | 0.30 ± 0.05 (0.22 – 0.51) |
| Clip dose (cGy) | 784 ± 224 (469 – 3146) |
| Max skin dose (cGy) | 521 ± 73 (223 – 607) |
| CTV V1.5ref (cm3) | 39 ± 18 (12 – 98) |
| CTV V2.0ref (cm3) | 15 ± 9 (5 – 58) |
| CTV V100 (cm3) | 63 ± 27 (25 –129) |
| CTV V90 (cm3) | 63 ± 28 (26 – 131) |
| CTV D100 (cGy) | 565 ± 125 (146 – 624) |
| CTV D90 (cGy) | 680 ± 97 (225 – 731) |
| CTV Mean dose (cGy) | 927 ± 80 (760 – 1092) |
| Conformity Index | 2.07 ± 0.84 (1.07 – 4.45) |
Fig. 2Frequency distribution of the index parameters of the ISBT–APBI treatment plan. a Reference volume (Vref). b Dose non-uniformity ratio (DNR). c Clip dose. d Percent CTV coverage
Fig. 3The relationship among activity, time and Vref. Activity is the activity the high-dose-rate source, time (s) is the total irradiation time, and Vref is the reference volume
Fig. 4The relationship between irradiated volume, fat necrosis, and local control rate. a fat necrosis and Vref. b relationship local control rate and Vref