Evaluation of commercial kit based on loop-mediated isothermal amplification for rapid detection of low levels of uninjured and injured Salmonella on duck meat, bean sprouts, and fishballs in Singapore.

Hazel Sin Yue Lim1, Qianwang Zheng1, Marta Miks-Krajnik2, Matthew Turner3, Hyun-Gyun Yuk4.   

Abstract

The objective of this study was to evaluate performance of the commercial kit based on loop-mediated isothermal amplification (LAMP) in comparison with the International Organization for Standardization method for detecting uninjured and sublethally injured Salmonella cells artificially inoculated at levels of 10(0) and 10(1) CFU/25 g on raw duck wing, raw mung bean sprouts, and processed fishballs. Injured cells were prepared by a heat treatment for duck wings and fishball samples and a chlorine treatment for bean sprout samples. Additionally, a validation study was performed on naturally contaminated food samples sold in Singapore. A total of 110 samples of each commodity were analyzed in this study. Regardless of inoculum levels, the detection by the commercial LAMP kit showed 100% sensitivity and specificity for both inoculated and uninoculated samples compared with the International Organization for Standardization method, with the exception of bean sprout samples. Only 20% of bean sprout samples inoculated with 10(0) CFU/25 g injured Salmonella cells were positive by using the commercial LAMP-based kit. However, all negative samples became positive following a secondary enrichment in Rappaport-Vassiliadis medium with soy broth or after concentration by centrifugation. These results suggest that secondary enrichment or centrifugation should be considered as an additional step to increase the sensitivity of the commercial LAMP-based kit with low numbers of injured target cells in samples with high background microflora (such as mung bean sprouts). The validation study also showed that the commercial LAMP-based kit provided 91% sensitivity and 95% specificity for naturally contaminated samples. Thus, this study demonstrates that the commercial LAMP-based kit might be a cost-effective method, as this system could provide rapid, accurate detection of both uninjured and injured Salmonella cells on raw duck wings, raw mung bean sprouts, and processed fishballs in less than 26 h.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26038914     DOI: 10.4315/0362-028X.JFP-14-535

Source DB:  PubMed          Journal:  J Food Prot        ISSN: 0362-028X            Impact factor:   2.077


  3 in total

1.  Evaluation of 3M™ loop-mediated isothermal amplification-based kit and 3M™ ready-to-use plating system for detection of Listeria in naturally contaminated leafy vegetables, chicken, and their related processing environments.

Authors:  Mustapha Goni Abatcha; Pei Ling Tan; Li-Oon Chuah; Gulam Rusul; S R Chandraprasad; Mohd Esah Effarizah
Journal:  Food Sci Biotechnol       Date:  2020-05-27       Impact factor: 2.391

Review 2.  Current and Future Perspectives on Isothermal Nucleic Acid Amplification Technologies for Diagnosing Infections.

Authors:  Godwin Attah Obande; Kirnpal Kaur Banga Singh
Journal:  Infect Drug Resist       Date:  2020-02-12       Impact factor: 4.003

Review 3.  Loop-Mediated Isothermal Amplification for Salmonella Detection in Food and Feed: Current Applications and Future Directions.

Authors:  Qianru Yang; Kelly J Domesle; Beilei Ge
Journal:  Foodborne Pathog Dis       Date:  2018-06       Impact factor: 3.171

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.