Literature DB >> 26036183

Performance of a next generation sequencing SNP assay on degraded DNA.

Katherine Butler Gettings1, Kevin M Kiesler1, Peter M Vallone1.   

Abstract

Forensic DNA casework samples are often of insufficient quantity or quality to generate full profiles by conventional DNA typing methods. Polymerase chain reaction (PCR) amplification of short tandem repeat (STR) loci is inherently limited in samples containing degraded DNA, as the cumulative size of repeat regions, primer binding regions, and flanking sequence is necessarily larger than the PCR template. Additionally, traditional capillary electrophoresis (CE) assay design further inherently limits shortening amplicons because the markers must be separated by size. Non-traditional markers, such as single nucleotide polymorphisms (SNPs) and insertion deletion polymorphisms (InDels), may yield more information from challenging samples due to their smaller amplicon size. In this study, the performance of a next generation sequencing (NGS) SNP assay and CE-based STR, mini-STR, and InDel assays was evaluated with a series of fragmented, size-selected samples. Information obtained from the NGS SNP assay exhibited higher overall inverse random match probability (1/RMP) values compared to the CE-based typing assays, with particular benefit for fragment sizes ≤ 150 base pairs (bp). The InDel, mini-STR, and NGS SNP assays all had similar percentages of loci with reportable alleles at this level of degradation; however, the relatively fewer number of loci in the InDel and mini-STR assays results in the NGS SNP assay having at least nine orders of magnitude higher 1/RMP values. In addition, the NGS SNP assay and three CE-based assays (two STR and one InDel assay) were tested using a dilution series consisting of 0.5 ng, 0.1 ng, and 0.05 ng non-degraded DNA. All tested assays showed similar percentages of loci with reportable alleles at these levels of input DNA; however, due to the larger number of loci, the NGS SNP assay and the larger of the two tested CE-based STR assays both resulted in considerably higher 1/RMP values than the other assays. These results indicate the potential advantage of NGS SNP assays for forensic analysis of degraded DNA samples. Published by Elsevier Ireland Ltd.

Entities:  

Keywords:  Degraded DNA; InDel; Next generation sequencing; SNP; STR

Mesh:

Substances:

Year:  2015        PMID: 26036183     DOI: 10.1016/j.fsigen.2015.04.010

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  13 in total

1.  An alternate workflow for preparing Precision ID Ancestry and Identity Panel libraries for Illumina sequencing.

Authors:  Melissa Kr Scheible; Emma K Timpano; Laura M Boggs; Kelly A Meiklejohn
Journal:  Int J Legal Med       Date:  2021-03-04       Impact factor: 2.686

2.  Case report: on the use of the HID-Ion AmpliSeq™ Ancestry Panel in a real forensic case.

Authors:  C Hollard; C Keyser; T Delabarde; A Gonzalez; C Vilela Lamego; V Zvénigorosky; B Ludes
Journal:  Int J Legal Med       Date:  2016-07-28       Impact factor: 2.686

3.  A novel forensic panel of 186-plex SNPs and 123-plex STR loci based on massively parallel sequencing.

Authors:  Xinyao Miao; Yuesheng Shen; Xiaojuan Gong; Huiyun Yu; Bowen Li; Liao Chang; Yinan Wang; Jingna Fan; Zuhuan Liang; Bowen Tan; Shengbin Li; Bao Zhang
Journal:  Int J Legal Med       Date:  2020-08-26       Impact factor: 2.686

4.  Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples.

Authors:  Amy S Holmes; Rachel Houston; Kyleen Elwick; David Gangitano; Sheree Hughes-Stamm
Journal:  Int J Legal Med       Date:  2017-11-24       Impact factor: 2.686

5.  A new strategy to confirm the identity of tumour tissues using single-nucleotide polymorphisms and next-generation sequencing.

Authors:  Lijuan Sun; Qi Liu; Shujin Li; Guanju Ma; Zhandong Wang; Chunling Ma; Bin Cong; Lihong Fu
Journal:  Int J Legal Med       Date:  2019-12-06       Impact factor: 2.686

6.  Massively parallel sequencing analysis of nondegraded and degraded DNA mixtures using the ForenSeq™ system in combination with EuroForMix software.

Authors:  Hsiao-Lin Hwa; Ming-Yih Wu; Wan-Chia Chung; Tsang-Ming Ko; Chih-Peng Lin; Hsiang-I Yin; Tsui-Ting Lee; James Chun-I Lee
Journal:  Int J Legal Med       Date:  2018-10-29       Impact factor: 2.686

7.  Applications of Probe Capture Enrichment Next Generation Sequencing for Whole Mitochondrial Genome and 426 Nuclear SNPs for Forensically Challenging Samples.

Authors:  Shelly Y Shih; Nikhil Bose; Anna Beatriz R Gonçalves; Henry A Erlich; Cassandra D Calloway
Journal:  Genes (Basel)       Date:  2018-01-22       Impact factor: 4.096

8.  Comparison of Two Massively Parallel Sequencing Platforms using 83 Single Nucleotide Polymorphisms for Human Identification.

Authors:  Dame Loveliness T Apaga; Sheila E Dennis; Jazelyn M Salvador; Gayvelline C Calacal; Maria Corazon A De Ungria
Journal:  Sci Rep       Date:  2017-03-24       Impact factor: 4.379

9.  Genome-Wide DNA from Degraded Petrous Bones and the Assessment of Sex and Probable Geographic Origins of Forensic Cases.

Authors:  Daniel Gaudio; Daniel M Fernandes; Ryan Schmidt; Olivia Cheronet; Debora Mazzarelli; Mirko Mattia; Tadhg O'Keeffe; Robin N M Feeney; Cristina Cattaneo; Ron Pinhasi
Journal:  Sci Rep       Date:  2019-06-03       Impact factor: 4.379

10.  Development and Verification of an Economical Method of Custom Target Library Construction.

Authors:  Xinyao Miao; Bowen Li; Yuesheng Shen; Huiyun Yu; Guoqiang Zhu; Chen Liang; Xiao Fu; Chu Wang; Shengbin Li; Bao Zhang
Journal:  ACS Omega       Date:  2020-05-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.