Literature DB >> 26031270

Intraoperative indocyanine green fluorescence angiography--an objective evaluation of anastomotic perfusion in colorectal surgery.

Bogdan Protyniak1, Anthony M Dinallo, William P Boyan, Roy M Dressner, Michael L Arvanitis.   

Abstract

The essentials for any bowel anastomosis are: adequate perfusion, tension free, accurate tissue apposition, and minimal local spillage. Traditionally, perfusion is measured by assessing palpable pulses in the mesentery, active bleeding at cut edges, and lack of tissue discoloration. However, subjective methods lack predictive accuracy for an anastomotic leak. We used intraoperative indocyanine green (ICG) fluorescence angiography to objectively assess colon perfusion before a bowel anastomosis. Seventy-seven laparoscopic colorectal operations, between June 2013 and June 2014, were retrospectively reviewed. The perfusion to the colon and ileum was clinically assessed, and then measured using the SPY Elite Imaging System. The absolute value provided an objective number on a 0-256 gray-scale to represent differences in ICG fluorescence intensity. The lowest absolute value was used in data analysis for each anastomosis (including small bowel) to represent the theoretical least perfused/weakest anastomotic area. The lowest absolute value recorded was 20 in a patient who underwent a laparoscopic right hemicolectomy for an adenoma, with no postoperative complications. Four low anterior resection patients had additional segments of descending colon resected. There was one mortality in a patient who underwent a laparoscopic right hemicolectomy. This study illustrates an initial experience with the SPY system in colorectal surgery. The SPY provides an objective, numerical value of bowel perfusion. However, evidence is scant as to the significance of these numbers. Large-scale randomized controlled trials are required to determine specific cutoff values correlated with surgical outcomes, specifically anastomotic leak rates.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26031270

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  24 in total

Review 1.  Emerging Trends in the Etiology, Prevention, and Treatment of Gastrointestinal Anastomotic Leakage.

Authors:  Sami A Chadi; Abe Fingerhut; Mariana Berho; Steven R DeMeester; James W Fleshman; Neil H Hyman; David A Margolin; Joseph E Martz; Elisabeth C McLemore; Daniela Molena; Martin I Newman; Janice F Rafferty; Bashar Safar; Anthony J Senagore; Oded Zmora; Steven D Wexner
Journal:  J Gastrointest Surg       Date:  2016-09-16       Impact factor: 3.452

2.  SAGES Technology and Value Assessment Committee safety and effectiveness analysis on immunofluorescence in the operating room for biliary visualization and perfusion assessment.

Authors:  Bryan J Sandler; Danny Sherwinter; Lucian Panait; Richard Parent; Jennifer Schwartz; David Renton
Journal:  Surg Endosc       Date:  2017-06-22       Impact factor: 4.584

3.  Quantitative perfusion assessment of intestinal anastomoses in pigs treated with glucagon-like peptide 2.

Authors:  Nikolaj Nerup; Linea Landgrebe Ring; Rune Broni Strandby; Charlotte Egeland; Morten Bo Søndergaard Svendsen; Jane Preuss Hasselby; Gro Linno Willemoe; Bolette Hartmann; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2018-10-18       Impact factor: 3.445

Review 4.  Complications of Minimally Invasive Surgery and Their Management.

Authors:  Joshua R Kaplan; Ziho Lee; Daniel D Eun; Adam C Reese
Journal:  Curr Urol Rep       Date:  2016-06       Impact factor: 3.092

5.  Quantification of fluorescence angiography in a porcine model.

Authors:  Nikolaj Nerup; Helene Schou Andersen; Rikard Ambrus; Rune Broni Strandby; Morten Bo Søndergaard Svendsen; Mads Holst Madsen; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2016-11-15       Impact factor: 3.445

Review 6.  Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysis.

Authors:  R Blanco-Colino; E Espin-Basany
Journal:  Tech Coloproctol       Date:  2017-12-11       Impact factor: 3.781

Review 7.  Green indocyanine fluorescence in robotic abdominal surgery.

Authors:  Giuseppe Spinoglio; Emilio Bertani; Simona Borin; Alessandra Piccioli; Wanda Petz
Journal:  Updates Surg       Date:  2018-08-29

Review 8.  Indocyanine green fluorescence angiography for intraoperative assessment of gastrointestinal anastomotic perfusion: a systematic review of clinical trials.

Authors:  Thea Helene Degett; Helene Schou Andersen; Ismail Gögenur
Journal:  Langenbecks Arch Surg       Date:  2016-03-11       Impact factor: 3.445

9.  Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study.

Authors:  Luigi Boni; Abe Fingerhut; Alessandro Marzorati; Stefano Rausei; Gianlorenzo Dionigi; Elisa Cassinotti
Journal:  Surg Endosc       Date:  2016-08-23       Impact factor: 4.584

Review 10.  Current status and future perspectives of fluorescence-guided surgery for cancer.

Authors:  Jonathan C DeLong; Robert M Hoffman; Michael Bouvet
Journal:  Expert Rev Anticancer Ther       Date:  2015-12-07       Impact factor: 4.512

View more