Field size consistency of nominally matched linacs.

T Kairn1, A Asena, P H Charles, B Hill, C M Langton, N D Middlebrook, R Moylan, J V Trapp.   

Abstract

Given that there is increasing recognition of the effect that sub-millimetre changes in collimator position can have on radiotherapy beam dosimetry, this study aimed to evaluate the potential variability in small field collimation that may exist between otherwise matched linacs. Field sizes and field output factors were measured using radiochromic film and an electron diode, for jaw- and MLC-collimated fields produced by eight dosimetrically matched Varian iX linacs (Varian Medical Systems, Palo Alto, USA). This study used nominal sizes from 0.6 × 0.6 to 10 × 10 cm(2), for jaw-collimated fields, and from 1 × 1 to 10 × 10 cm(2) for MLC-collimated fields, delivered from a zero (head up, beam directed vertically downward) gantry angle. Differences between the field sizes measured for the eight linacs exceeded the uncertainty of the film measurements and the repositioning uncertainty of the jaws and MLCs on one linac. The dimensions of fields defined by MLC leaves were more consistent between linacs, while also differing more from their nominal values than fields defined by orthogonal jaws. The field output factors measured for the different linacs generally increased with increasing measured field size for the nominal 0.6 × 0.6 to 1 × 1 cm(2) fields, and became consistent between linacs for nominal field sizes of 2 × 2 cm(2) and larger. The inclusion in radiotherapy treatment planning system beam data of small field output factors acquired in fields collimated by jaws (rather than the more-reproducible MLCs), associated with either the nominal or the measured field sizes, should be viewed with caution. The size and reproducibility of the fields (especially the small fields) used to acquire treatment planning data should be investigated thoroughly as part of the linac or planning system commissioning process. Further investigation of these issues, using different linac models, collimation systems and beam orientations, is recommended.

Entities:  

Mesh:

Year:  2015        PMID: 26025010     DOI: 10.1007/s13246-015-0349-2

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  Determination of inflection points of CyberKnife dose profiles within acceptability criteria of deviations in measurements.

Authors:  Neslihan Sarıgül; Fazlı Yağız Yedekçi; Mete Yeğiner; Fadıl Akyol; Haluk Utku
Journal:  Rep Pract Oncol Radiother       Date:  2019-11-12

2.  Consistency of small-field dosimetry, on and off axis, in beam-matched linacs used for stereotactic radiosurgery.

Authors:  Luis Muñoz; Tomas Kron; Marco Petasecca; Joseph Bucci; Michael Jackson; Peter Metcalfe; Anatoly B Rosenfeld; Giordano Biasi
Journal:  J Appl Clin Med Phys       Date:  2021-01-13       Impact factor: 2.102

3.  Verification of Surface Dose for Flattening Filter and Flattening Filter Free Beams in Beam-Matched Medical Linear Accelerators.

Authors:  N Sushma; Shanmukhappa Kaginelli; Sathiaraj Palanivel; K M Ganesh
Journal:  Asian Pac J Cancer Prev       Date:  2021-08-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.