Literature DB >> 26022355

Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT).

I Barnaure1, P Pollak2, S Momjian3, J Horvath2, K O Lovblad1, C Boëx2, J Remuinan4, P Burkhard2, M I Vargas5.   

Abstract

INTRODUCTION: Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software.
METHODS: Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T.
RESULTS: Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm.
CONCLUSION: Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS.

Entities:  

Keywords:  CT; Deep brain stimulation; Electrode position; Image fusion; MRI

Mesh:

Year:  2015        PMID: 26022355     DOI: 10.1007/s00234-015-1547-z

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  19 in total

1.  A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination.

Authors:  D Kondziolka; P K Dempsey; L D Lunsford; J R Kestle; E J Dolan; E Kanal; R R Tasker
Journal:  Neurosurgery       Date:  1992-03       Impact factor: 4.654

2.  Assessment of contact location in subthalamic stimulation for Parkinson's disease by co-registration of computed tomography images.

Authors:  Fumiaki Yoshida; Yasushi Miyagi; Takato Morioka; Kimiaki Hashiguchi; Nobuya Murakami; Kenichi Matsumoto; Shinji Nagata; Tomio Sasaki
Journal:  Stereotact Funct Neurosurg       Date:  2008-03-12       Impact factor: 1.875

3.  Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series.

Authors:  Paul S Larson; R Mark Richardson; Philip A Starr; Alastair J Martin
Journal:  Stereotact Funct Neurosurg       Date:  2007-12-12       Impact factor: 1.875

4.  Electrode location and clinical outcome in hippocampal electrical stimulation for mesial temporal lobe epilepsy.

Authors:  Percy Bondallaz; Colette Boëx; Andrea O Rossetti; Giovanni Foletti; Laurent Spinelli; Serge Vulliemoz; Margitta Seeck; Claudio Pollo
Journal:  Seizure       Date:  2013-03-27       Impact factor: 3.184

5.  Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery.

Authors:  T S Sumanaweera; J R Adler; S Napel; G H Glover
Journal:  Neurosurgery       Date:  1994-10       Impact factor: 4.654

6.  Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report.

Authors:  Jaimie M Henderson; Jean Tkach; Michael Phillips; Kenneth Baker; Frank G Shellock; Ali R Rezai
Journal:  Neurosurgery       Date:  2005-11       Impact factor: 4.654

7.  Combined (thalamotomy and stimulation) stereotactic surgery of the VIM thalamic nucleus for bilateral Parkinson disease.

Authors:  A L Benabid; P Pollak; A Louveau; S Henry; J de Rougemont
Journal:  Appl Neurophysiol       Date:  1987

8.  Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus.

Authors:  A L Benabid; P Pollak; C Gervason; D Hoffmann; D M Gao; M Hommel; J E Perret; J de Rougemont
Journal:  Lancet       Date:  1991-02-16       Impact factor: 79.321

9.  A simple method to assess accuracy of deep brain stimulation electrode placement: pre-operative stereotactic CT + postoperative MR image fusion.

Authors:  Paolo Ferroli; Angelo Franzini; Carlo Marras; Elio Maccagnano; Ludovico D'Incerti; Giovanni Broggi
Journal:  Stereotact Funct Neurosurg       Date:  2004       Impact factor: 1.875

Review 10.  Update on surgery for Parkinson's disease.

Authors:  Jens Volkmann
Journal:  Curr Opin Neurol       Date:  2007-08       Impact factor: 5.710

View more
  7 in total

1.  Accuracy of Microelectrode Trajectory Adjustments during DBS Assessed by Intraoperative CT.

Authors:  Sander Bus; Gian Pal; Bichun Ouyang; Pepijn van den Munckhof; Maarten Bot; Sepehr Sani; Leo Verhagen Metman
Journal:  Stereotact Funct Neurosurg       Date:  2018-08-24       Impact factor: 1.875

2.  Borders of STN determined by MRI versus the electrophysiological STN. A comparison using intraoperative CT.

Authors:  Sander Bus; Pepijn van den Munckhof; Maarten Bot; Gian Pal; Bichun Ouyang; Sepehr Sani; Leo Verhagen Metman
Journal:  Acta Neurochir (Wien)       Date:  2017-12-23       Impact factor: 2.216

3.  Localization of Deep Brain Stimulation Contacts Using Corticospinal/Corticobulbar Tracts Stimulation.

Authors:  Julien F Bally; Maria-Isabel Vargas; Judit Horvath; Vanessa Fleury; Pierre Burkhard; Shahan Momjian; Pierre Pollak; Colette Boex
Journal:  Front Neurol       Date:  2017-05-31       Impact factor: 4.003

4.  MRI T2-Weighted Imaging and Fat-Suppressed T2-Weighted Imaging Image Fusion Technology Improves Image Discriminability for the Evaluation of Anal Fistulas.

Authors:  Shi Ting Feng; Mengqi Huang; Zhi Dong; Ling Xu; Yin Li; Yingmei Jia; Huasong Cai; Bingqi Shen; Zi Ping Li
Journal:  Korean J Radiol       Date:  2019-03       Impact factor: 3.500

5.  Cortical hemodynamic mapping of subthalamic nucleus deep brain stimulation in Parkinsonian patients, using high-density functional near-infrared spectroscopy.

Authors:  Mahdi Mahmoudzadeh; Fabrice Wallois; Mélissa Tir; Pierre Krystkowiak; Michel Lefranc
Journal:  PLoS One       Date:  2021-01-25       Impact factor: 3.240

6.  Value of CT-MRI fusion in iodine-125 brachytherapy for high-grade glioma.

Authors:  Yang Gao; Yan Han; Guo Nan; Man Hu; Xiaobin Zhou; Xiaokun Hu
Journal:  Oncotarget       Date:  2017-12-01

7.  Methodology, outcome, safety and in vivo accuracy in traditional frame-based stereoelectroencephalography.

Authors:  Lars E van der Loo; Olaf E M G Schijns; Govert Hoogland; Albert J Colon; G Louis Wagner; Jim T A Dings; Pieter L Kubben
Journal:  Acta Neurochir (Wien)       Date:  2017-07-05       Impact factor: 2.216

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.