Literature DB >> 26017127

Agreement between radial and femoral arterial blood pressure measurements during orthotopic liver transplantation.

Matthew Lee1, Laurence Weinberg2, Brett Pearce2, Nicholas Scurrah2, David A Story2, Param Pillai2, Peter R McCall2, Larry P McNicol2, Philip J Peyton2.   

Abstract

OBJECTIVE: To study agreement between radial and femoral arterial pressure measurements in orthotopic liver transplantation (OLTx) surgery to determine whether arterial cannulation sites are interchangeable. DESIGN, SETTING AND PARTICIPANTS: Prospective observational study of 25 patients undergoing OLTx surgery.
METHODS: Radial and femoral arteries were cannulated with standardised arterial line kits. Radial and femoral mean arterial pressure (MAP), systolic arterial pressure (SAP), diastolic arterial pressure (DAP) and pulse pressure (PP) were measured at four time points (30 minutes after induction of anaesthesia, 30 minutes after the start of the anhepatic phase, 30 minutes after liver graft reperfusion and 30 minutes after the start of bile duct anastomosis). MAIN OUTCOME MEASURES: The bias, precision and limits of agreement between radial and femoral arterial pressures were calculated in accordance with Bland-Altman statistics.
RESULTS: Radial-femoral differences in MAP (mean difference, 4.8 mmHg [SD, 4.5 mmHg]), limits of agreement (- 13.6 and 8.8, P < 0.001) and DAP showed clinically acceptable agreement between measurement sites across all time points. However, clinically significant differences between radial and femoral SAPs (mean difference, - 14.9 mmHg [SD, 24.8 mmHg]) and limits of agreement (- 63.5 and 33.7, P < 0.001) occurred overall. This difference started after portal vein clamping and remained significant throughout the remainder of the operation.
CONCLUSION: Radial artery SAP underestimates femoral artery measurements significantly but unpredictably. As femoral measurement is more likely to reflect central arterial pressure, radial SAP measurement is not reliable in adults undergoing OLTx.

Entities:  

Mesh:

Year:  2015        PMID: 26017127

Source DB:  PubMed          Journal:  Crit Care Resusc        ISSN: 1441-2772            Impact factor:   2.159


  9 in total

1.  Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.

Authors:  Matthew Lee; Laurence Weinberg; Brett Pearce; Nicholas Scurrah; David A Story; Param Pillai; Peter R McCall; Larry P McNicol; Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2016-02-16       Impact factor: 2.502

2.  Can we trust radial artery pressure monitoring for cardiac surgery?

Authors:  Matthias Jacquet-Lagrèze; Adrian Costescu; André Denault
Journal:  Can J Anaesth       Date:  2022-10-05       Impact factor: 6.713

3.  Agreements between mean arterial pressure from radial and femoral artery measurements in refractory shock patients.

Authors:  Hemmawan Wisanusattra; Bodin Khwannimit
Journal:  Sci Rep       Date:  2022-05-25       Impact factor: 4.996

4.  Evaluation of New Calibrated Pulse-Wave Analysis (VolumeViewTM/EV1000TM) for Cardiac Output Monitoring Undergoing Living Donor Liver Transplantation.

Authors:  MiHye Park; Sangbin Han; Gaab Soo Kim; Mi Sook Gwak
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

5.  Correlation between radial and femoral arterial blood pressure during reperfusion in living donor liver transplantation.

Authors:  Manu Thomas; Lakshmi Kumar; Priyanka Jain; Chitra Sarma; Shabala Paul; Sudhindran Surendran
Journal:  Indian J Anaesth       Date:  2021-04-15

6.  Ability of dynamic preload indices to predict fluid responsiveness in a high femoral-to-radial arterial pressure gradient: a retrospective study.

Authors:  Seon Ju Kim; So Yeon Kim; Hye Sun Lee; Goeun Park; Eun Jang Yoon; Sungtaik Heo; Bon-Nyeo Koo
Journal:  Anesth Pain Med (Seoul)       Date:  2021-10-22

7.  Correlation of Cardiac Output by Arterial Contour-Derived Cardiac Output Monitor Versus Pulmonary Artery Catheter in Liver Transplant: Experience at an Indian Center.

Authors:  Kusuma Halemani; Lakshmi Kumar; Bhadrinath Narayanan; Sunil Rajan; Pavithra Ramamurthi; Abish Sudhakar
Journal:  Turk J Anaesthesiol Reanim       Date:  2022-04

8.  Femoral Pulse Pressure Variation Is Not Interchangeable with Radial Pulse Pressure Variation during Living Donor Liver Transplantation.

Authors:  Doyeon Kim; Jin Hee Ahn; Sangbin Han; Justin Sangwook Ko; Mi Sook Gwak; Gaab Soo Kim
Journal:  J Pers Med       Date:  2022-08-22

Review 9.  Provisional Decision-Making for Perioperative Blood Pressure Management: A Narrative Review.

Authors:  Qiliang Song; Jipeng Li; Zongming Jiang
Journal:  Oxid Med Cell Longev       Date:  2022-07-11       Impact factor: 7.310

  9 in total