Literature DB >> 26015831

Droplet confinement and leakage: Causes, underlying effects, and amelioration strategies.

Aaron P Debon1, Robert C R Wootton1, Katherine S Elvira1.   

Abstract

The applicability of droplet-based microfluidic systems to many research fields stems from the fact that droplets are generally considered individual and self-contained reaction vessels. This study demonstrates that, more often than not, the integrity of droplets is not complete, and depends on a range of factors including surfactant type and concentration, the micro-channel surface, droplet storage conditions, and the flow rates used to form and process droplets. Herein, a model microfluidic device is used for droplet generation and storage to allow the comparative study of forty-four different oil/surfactant conditions. Assessment of droplet stability under these conditions suggests a diversity of different droplet failure modes. These failure modes have been classified into families depending on the underlying effect, with both numerical and qualitative models being used to describe the causative effect and to provide practical solutions for droplet failure amelioration in microfluidic systems.

Entities:  

Year:  2015        PMID: 26015831      PMCID: PMC4409622          DOI: 10.1063/1.4917343

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  40 in total

1.  Dynamic pattern formation in a vesicle-generating microfluidic device.

Authors:  T Thorsen; R W Roberts; F H Arnold; S R Quake
Journal:  Phys Rev Lett       Date:  2001-04-30       Impact factor: 9.161

2.  A microfluidic approach for high-throughput droplet interface bilayer (DIB) formation.

Authors:  C E Stanley; K S Elvira; X Z Niu; A D Gee; O Ces; J B Edel; A J Demello
Journal:  Chem Commun (Camb)       Date:  2010-01-25       Impact factor: 6.222

3.  Plasma stencilling methods for cell patterning.

Authors:  Jean-Philippe Frimat; Heike Menne; Antje Michels; Silke Kittel; Raffael Kettler; Sabine Borgmann; Joachim Franzke; Jonathan West
Journal:  Anal Bioanal Chem       Date:  2009-05-17       Impact factor: 4.142

Review 4.  Microfluidic-integrated biosensors: prospects for point-of-care diagnostics.

Authors:  Suveen Kumar; Saurabh Kumar; Md Azahar Ali; Pinki Anand; Ved Varun Agrawal; Renu John; Sagar Maji; Bansi D Malhotra
Journal:  Biotechnol J       Date:  2013-09-06       Impact factor: 4.677

5.  Stability of a jet in confined pressure-driven biphasic flows at low Reynolds number in various geometries.

Authors:  Pierre Guillot; Annie Colin; Armand Ajdari
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2008-07-17

6.  Influence of Interfacial Properties of Lipophilic Surfactants on Water-in-Oil Emulsion Stability

Authors: 
Journal:  J Colloid Interface Sci       Date:  1998-01-01       Impact factor: 8.128

7.  Chemically induced coalescence in droplet-based microfluidics.

Authors:  Ilke Akartuna; Donald M Aubrecht; Thomas E Kodger; David A Weitz
Journal:  Lab Chip       Date:  2015-02-21       Impact factor: 6.799

8.  Surface modification of poly(dimethylsiloxane) with a perfluorinated alkoxysilane for selectivity toward fluorous tagged peptides.

Authors:  Dan Wang; Vishya Goel; Richard D Oleschuk; J Hugh Horton
Journal:  Langmuir       Date:  2007-12-29       Impact factor: 3.882

9.  Self-assembly of octadecyltrichlorosilane: Surface structures formed using different protocols of particle lithography.

Authors:  Chamarra K Saner; Kathie L Lusker; Zorabel M Lejeune; Wilson K Serem; Jayne C Garno
Journal:  Beilstein J Nanotechnol       Date:  2012-02-09       Impact factor: 3.649

Review 10.  The use of microfluidics in hemostasis: clinical diagnostics and biomimetic models of vascular injury.

Authors:  Keith B Neeves; Abimbola A Onasoga; Adam R Wufsus
Journal:  Curr Opin Hematol       Date:  2013-09       Impact factor: 3.284

View more
  5 in total

1.  Approach to classify, separate, and enrich objects in groups using ensemble sorting.

Authors:  Rebecca Turk-MacLeod; Alon Henson; Marc Rodriguez-Garcia; Graham M Gibson; Gerardo Aragon Camarasa; Dario Caramelli; Miles J Padgett; Leroy Cronin
Journal:  Proc Natl Acad Sci U S A       Date:  2018-05-14       Impact factor: 11.205

2.  Investigating the effect of phospholipids on droplet formation and surface property evolution in microfluidic devices for droplet interface bilayer (DIB) formation.

Authors:  Elanna B Stephenson; Ricardo García Ramírez; Sean Farley; Katherine Adolph-Hammond; Gihyun Lee; John M Frostad; Katherine S Elvira
Journal:  Biomicrofluidics       Date:  2022-08-23       Impact factor: 3.258

3.  Simple and Precise Counting of Viable Bacteria by Resazurin-Amplified Picoarray Detection.

Authors:  Kuangwen Hsieh; Helena C Zec; Liben Chen; Aniruddha M Kaushik; Kathleen E Mach; Joseph C Liao; Tza-Huei Wang
Journal:  Anal Chem       Date:  2018-07-17       Impact factor: 6.986

4.  Easily fabricated monolithic fluoropolymer chips for sensitive long-term absorbance measurement in droplet microfluidics.

Authors:  Adrian M Nightingale; Sammer-Ul Hassan; Kyriacos Makris; Wahida T Bhuiyan; Terry J Harvey; Xize Niu
Journal:  RSC Adv       Date:  2020-08-21       Impact factor: 3.361

Review 5.  Materials and methods for droplet microfluidic device fabrication.

Authors:  Katherine S Elvira; Fabrice Gielen; Scott S H Tsai; Adrian M Nightingale
Journal:  Lab Chip       Date:  2022-03-01       Impact factor: 7.517

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.