| Literature DB >> 26015816 |
Kakarla V Chalam1, Wenhua Li1, Keyvan Koushan1, Sandeep Grover1, Sankarathi Balaiya1.
Abstract
BACKGROUND: The objective of the study was to determine the safety parameters of using brilliant blue green (BBG) for chromovitrectomy by assessing the cytotoxicity of BBG on cultured retinal ganglion cells (RGCs) exposed to illumination.Entities:
Keywords: Brilliant blue green; Chromovitrectomy; Cytotoxicity; Endoillumination; Retinal ganglion cells
Year: 2015 PMID: 26015816 PMCID: PMC4432893 DOI: 10.14740/jocmr2085e
Source DB: PubMed Journal: J Clin Med Res ISSN: 1918-3003
Figure 1Schematic representation explaining the exposure of RGCs to BBG during intraocular surgery as well as cell culture setup. (a) Diffuse light illumination. (b) Focal illumination. LS: light source; LP: light pipe; D: distance; RGC: retinal ganglion cell; BBG: brilliant blue green.
Figure 2Experimental illustration. (a) Measurement of metal halide light illumination using a light meter at a certain distance from the light source. (b) Measurement of metal halide light illumination using a light meter directly from the light source. (c) Exposure of cultured RGCs to metal halide illumination. LS: light source; LP: light pipe; LM: light meter; dist: distance; RGC: retinal ganglion cell; BBG: brilliant blue green.
Viability of RGCs After Illumination at 1 cm and 2.5 cm Distance With Higher and Medium Illumination of Metal Halide Light Source Using the WST-1 Assay
| Distance of illumination (cm) | Concentration of dye (mg/mL) | Higher illumination cell viability ± SD (%) | Medium illumination cell viability ± SD (%) | ||||
|---|---|---|---|---|---|---|---|
| 1 min | 5 min | 15 min | 1 min | 5 min | 15 min | ||
| 1 | 0.25 | 89.8 ± 7.4 | 79.6 ± 4.9 | 56.7 ± 4.0 | 99.1 ± 14.5 | 94.4 ± 18.8 | 73.7 ± 16.0 |
| 0.5 | 79 ± 13.1 | 66.7 ± 13.6 | 53.1 ± 11.3 | 96.5 ± 8.5 | 84.5 ± 11.0 | 72.3 ± 12.8 | |
| 2.5 | 0.25 | 97.5 ± 16.4 | 96.7 ± 15.2 | 92.4 ± 15.2 | 95.1 ± 7.2 | 93.8 ± 7.2 | 93.0 ± 1.8 |
| 0.5 | 98.9 ± 12.6 | 94.8 ± 12.4 | 82.7 ± 15.7 | 94.5 ± 3.9 | 94.0 ± 2.9 | 87.0 ± 7.0 | |
Figure 3Evaluating the cytotoxic effect of brilliant blue green at 1 cm metal halide distance illumination on retinal ganglion cells using WST-1 assay at high (a) and medium illumination (b). X-axis represents the time dependent exposure in minutes; Y-axis represents number of viable cells expressed as percent of control (N = 4); (c) represents the trend line.
Figure 4Evaluating the cytotoxic effect of brilliant blue green at 2.5 cm metal halide distance illumination on retinal ganglion cells using WST-1 assay at high (a) and medium illumination (b). X-axis represents the time dependent exposure in minutes; Y-axis represents number of viable cells expressed as percent of control (N = 4); (c) represents the trend line.
Figure 5Evaluating the cytotoxic effect of brilliant blue green at 1 cm metal halide distance illumination on retinal ganglion cells using CellTiter 96® AQueous One proliferation assay at high (a) and medium illumination (b). X-axis represents the time dependent exposure in minutes; Y-axis represents number of viable cells expressed as percent of control (N = 4); (c) represents the trend line.
Viability of RGCs After Illumination at 1 cm and 2.5 cm Distance With Higher and Medium Illumination of Metal Halide Light Source Using the CellTiter 96® AQueous One Assay
| Distance of illumination (cm) | Concentration of dye (mg/mL) | Higher illumination cell viability ± SD (%) | Medium illumination cell viability ± SD (%) | ||||
|---|---|---|---|---|---|---|---|
| 1 min | 5 min | 15 min | 1 min | 5 min | 15 min | ||
| 1 | 0.25 | 93.5 ± 5.3 | 90.4 ± 3.1 | 88.2 ± 6.7 | 98.9 ± 6.5 | 97.8 ± 7.9 | 94.2 ± 4.8 |
| 0.5 | 88.2 ± 5.5 | 85.3 ± 7.9 | 83.6 ± 4.1 | 96.2 ± 8.1 | 96.4 ± 5.9 | 88.9 ± 7.1 | |
| 2.5 | 0.25 | 95.6 ± 1.8 | 91.2 ± 3.2 | 84 ± 2.3 | 97.2 ± 7.6 | 93.7 ± 8.6 | 91.4 ± 7.9 |
| 0.5 | 93.3 ± 1.3 | 83.2 ± 2.0 | 83.1 ± 2.8 | 96.3 ± 8.5 | 91.6 ± 6.9 | 88.2 ± 7.8 | |
Figure 6Evaluating the cytotoxic effect of brilliant blue green at 2.5 cm metal halide distance illumination on retinal ganglion cells using CellTiter 96® AQueous One proliferation assay at high (a) and medium illumination (b). X-axis represents the time dependent exposure in minutes; Y-axis represents number of viable cells expressed as percent of control (N = 4); (c) represents the trend line.