Literature DB >> 26009910

Assessment of the Effect of CO2 Laser Irradiation on the Reduction of Bacteria Seeded on Commercially Available Sandblasted Acid-Etched Titanium Dental Implants: An In Vitro Study.

Cimara Fortes Ferreira, Jegdish Babu, Erica Krohn Jany Migliorati, Sydney Stein, Franklin Garcia-Godoy.   

Abstract

PURPOSE: To evaluate the capability of carbon dioxide (CO₂) laser in reducing Escherichia coli on sandblasted acid-etched (SAE) titanium dental implants.
MATERIALS AND METHODS: SAE dental implants were contaminated with E coli, incubated in a sterile bacterial culture medium for 24 hours, and then exposed to CO₂ laser (10,600-nm wavelength) in superpulsed waves (SPW) at 1.5, 1.7, and 2 W at 100-Hz frequency and continuous wave (CW) at 1.5, 2, and 2.5 W. The presence of bacteria trapped in the implant surfaces after contamination and decontamination was verified using spectrophotometry. Scanning electron microscopy (SEM) was used to evaluate the topography of laser irradiation. After implant surface contamination was verified, implants were exposed to CO₂ laser irradiation, and bacterial growth was measured with spectrophotometry.
RESULTS: The control implants showed the highest bacterial growth (100% growth). Implants exposed to laser showed progressive increase in the percentage of decontamination (DC%) corresponding to the higher wattage in the SPW and CW groups. The DC% were 20.4%, 49.6%, and 51.7% in the SPW group at 100 Hz, at 1.5, 1.7, and 2 W of power, respectively. In the CW group, the DC% were 34.3%, 69.9%, and 85.5% at 1.7, 2, and 2.5 W, respectively. Kruskal-Wallis statistical analysis showed a significant difference between the groups (P < .05). In the pulsed mode (100-Hz) group, statistical analysis showed that the DC% of 1.5 W was significantly lower than the 2 W power. In the CW group, statistical analysis showed that the DC% at 1.7 W was significantly lower (P < .05) than with the other treatments. SEM assessment showed craterlike wear damages and accretions to the implant surfaces that increased progressively as the laser wattage increased.
CONCLUSION: CO₂ laser irradiation failed to completely decontaminate the implant surfaces. SEM analysis demonstrated damage to the top of the dental implant threads at all settings studied. Thus, CO₂ laser irradiation may not be the optimal method to decontaminate implants.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26009910     DOI: 10.11607/jomi.3925

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  CO2 laser surface treatment of failed dental implants for re-implantation: an animal study.

Authors:  Shahin Kasraei; Parviz Torkzaban; Bahar Shams; Seyed Mohammad Hosseinipanah; Maryam Farhadian
Journal:  Lasers Med Sci       Date:  2016-04-28       Impact factor: 3.161

2.  Bacterial reduction effect of four different dental lasers on titanium surfaces in vitro.

Authors:  W Patrick Misischia; Pinelopi Xenoudi; Raymond A Yukna; Michael J Schurr
Journal:  Lasers Med Sci       Date:  2021-07-27       Impact factor: 3.161

3.  Antimicrobial Efficacy of Different Decontamination Methods as Tested on Dental Implants with Various Types of Surfaces.

Authors:  Paweł Kubasiewicz-Ross; Jakub Hadzik; Tomasz Gedrange; Marzena Dominiak; Kamil Jurczyszyn; Artur Pitułaj; Izabela Nawrot-Hadzik; Olga Bortkiewicz; Małgorzata Fleischer
Journal:  Med Sci Monit       Date:  2020-02-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.