Rotating permanent magnet excitation for blood flow measurement.

Sarath S Nair1, V Vinodkumar2, V Sreedevi2, D S Nagesh2.   

Abstract

A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

Keywords:  Blood flow measurement; Fluid flow measurement; Permanent magnet

Mesh:

Year:  2015        PMID: 26002594     DOI: 10.1007/s11517-015-1310-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Problems with an electromagnetic blood flowmeter.

Authors:  R Hickman; J H Crosier; P Smith; E J Immelman; J Terblanche
Journal:  S Afr Med J       Date:  1975-02-22

2.  Problems in the measurement of blood flow by magnetic induction.

Authors:  D G WYATT
Journal:  Phys Med Biol       Date:  1961-04       Impact factor: 3.609

3.  Zero error in induction flowmeters employing a permanent magnet.

Authors:  D G WYATT
Journal:  Phys Med Biol       Date:  1961-04       Impact factor: 3.609

4.  Fiber-coupled self-mixing diode-laser Doppler velocimeter: technical aspects and flow velocity profile disturbances in water and blood flows.

Authors:  M H Koelink; F F de Mul; A L Weijers; J Greve; R Graaff; A C Dassel; J G Aarnoudse
Journal:  Appl Opt       Date:  1994-08-20       Impact factor: 1.980

5.  Novel approaches to the measurement of arterial blood flow from dynamic digital X-ray images.

Authors:  Kawal S Rhode; Tryphon Lambrou; David J Hawkes; Alexander M Seifalian
Journal:  IEEE Trans Med Imaging       Date:  2005-04       Impact factor: 10.048

Review 6.  Measurement of blood flow by ultrasound: accuracy and sources of error.

Authors:  R W Gill
Journal:  Ultrasound Med Biol       Date:  1985 Jul-Aug       Impact factor: 2.998

7.  An ultrasonic pulsed Doppler system for measuring blood flow in small vessels.

Authors:  C J Hartley; J S Cole
Journal:  J Appl Physiol       Date:  1974-10       Impact factor: 3.531

8.  Simultaneous comparison and calibration of the Doppler and electromagnetic flowmeters.

Authors:  S F Vatner; D Franklin; R L VanCitters
Journal:  J Appl Physiol       Date:  1970-12       Impact factor: 3.531

9.  The dye dilution method for measurement of cardiac output.

Authors:  P Lund-Johansen
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983