Literature DB >> 25998069

The Optimal Angle of Head Rotation for Internal Jugular Cannulation as Determined by Ultrasound Evaluation.

Vincent DeAngelis1, John Denny1, Darrick Chyu1, Thomas Jan1, Anthony Lemaire2, Antonio Chiricolo1, Al Solina3.   

Abstract

OBJECTIVES: The aim of this study was to determine the degree of head rotation that creates the maximal anatomic separation between the right internal jugular vein and the carotid artery.
DESIGN: Single-center prospective, observational cohort study.
SETTING: University medical center. PARTICIPANTS: Fifty patients aged>21 years and undergoing cardiac surgery.
INTERVENTIONS: An ultrasound machine equipped with a digital caliper was used to determine the relational anatomy of the internal jugular vein and the carotid artery, with patients in the Trendelenburg position at head angles of -15°, 0°,+15°,+30°,+45°,+60°,+75°, and+90°.
MEASUREMENTS AND MAIN RESULTS: When examining the percentage of the internal jugular vein vertical diameter that is not overlapped by the carotid artery (vertically unencumbered), there was a difference between the head angle groups (p<0.01). Unencumbered vertical distance was different between+75° versus 0°, and+75° versus+15°. At+75°, 60.3%±5.3% of the internal jugular vein was unencumbered vertically, whereas at 0°, it was 37.2%±3.9%, and at+15° it was 40.3%±3.8%. Only 72% of the patients were able to position their head at+75°, and 54% of the subjects were able to position their head at+90°.
CONCLUSION: The authors found the internal jugular vein becomes more vertically separated from the carotid artery at more extreme angles of contralateral head rotation.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  carotid artery injury; central line; central line complications; internal jugular cannulation; internal jugular vein; ultrasound

Mesh:

Year:  2015        PMID: 25998069     DOI: 10.1053/j.jvca.2015.02.007

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  2 in total

Review 1.  Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice.

Authors:  Bernd Saugel; Thomas W L Scheeren; Jean-Louis Teboul
Journal:  Crit Care       Date:  2017-08-28       Impact factor: 9.097

2.  Proper Angle of Sono-guided Central Venous Line Insertion.

Authors:  Hassan Barzegari; Arash Forouzan; Mohammad Ali Fahimi; Behzad Zohrevandi; Mandana Ghanavati
Journal:  Emerg (Tehran)       Date:  2016
  2 in total