Literature DB >> 25996580

Physiologically Modeled Pulse Dynamics to Improve Function in In Vitro-Endothelialized Small-Diameter Vascular Grafts.

Joseph S Uzarski1, Jhon Cores1, Peter S McFetridge1.   

Abstract

The lack of a functional endothelium on small-diameter vascular grafts leads to intimal hyperplasia and thrombotic occlusion. Shear stress conditioning through controlled hydrodynamics within in vitro perfusion bioreactors has shown promise as a mechanism to drive endothelial cell (EC) phenotype from an activated, pro-inflammatory wound state toward a quiescent functional state that inhibits responses that lead to occlusive failure. As part of an overall design strategy to engineer functional vascular grafts, we present a novel two-phase shear conditioning approach to improve graft endothelialization. Axial rotation was first used to seed uniform EC monolayers onto the lumenal surface of decellularized scaffolds derived from the human umbilical vein. Using computer-controlled perfusion circuits, a flow-ramping paradigm was applied to adapt endothelia to arterial levels of fluid shear stress and pressure without graft denudation. The effects of constant pulse frequencies (CF) on EC quiescence were then compared with pulse frequencies modeled from temporal fluctuations in blood flow observed in vivo, termed physiologically modeled pulse dynamics (PMPD). Constructs exposed to PMPD for 72 h expressed a more functional transcriptional profile, lower metabolic activity (39.8% ± 8.4% vs. 62.5% ± 11.5% reduction, p = 0.012), and higher nitric oxide production (80.42 ± 23.93 vs. 48.75 ± 6.93 nmol/10(5) cells, p = 0.028) than those exposed to CF. By manipulating in vitro flow conditions to mimic natural physiology, endothelialized vascular grafts can be stimulated to express a nonactivated phenotype that would better inhibit peripheral cell adhesion and smooth muscle cell hyperplasia, conditions that typically lead to occlusive failure. Development of robust, functional endothelia on vascular grafts by modulation of environmental conditions within perfusion bioreactors may ultimately improve clinical outcomes in vascular bypass grafting.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25996580      PMCID: PMC4638211          DOI: 10.1089/ten.TEC.2015.0110

Source DB:  PubMed          Journal:  Tissue Eng Part C Methods        ISSN: 1937-3384            Impact factor:   3.056


  45 in total

Review 1.  In vitro endothelialized ePTFE prostheses: clinical update 20 years after the first realization.

Authors:  L Bordenave; Ph Fernandez; M Rémy-Zolghadri; S Villars; R Daculsi; D Midy
Journal:  Clin Hemorheol Microcirc       Date:  2005       Impact factor: 2.375

2.  Development of the human umbilical vein scaffold for cardiovascular tissue engineering applications.

Authors:  Joel Daniel; Koki Abe; Peter S McFetridge
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

Review 3.  Phenotypic heterogeneity of the endothelium: I. Structure, function, and mechanisms.

Authors:  William C Aird
Journal:  Circ Res       Date:  2007-02-02       Impact factor: 17.367

4.  A 30-year odyssey with the umbilical vein graft.

Authors:  Herbert Dardik
Journal:  J Am Coll Surg       Date:  2006-10       Impact factor: 6.113

Review 5.  Endothelial progenitor cell-seeded grafts: rash and risky.

Authors:  Joris I Rotmans; Jan M M Heyligers; Erik S G Stroes; Gerard Pasterkamp
Journal:  Can J Cardiol       Date:  2006-11       Impact factor: 5.223

6.  Properties of the human umbilical vein as a living scaffold for a tissue-engineered vessel graft.

Authors:  Markus Hoenicka; Karla Lehle; Volker R Jacobs; Franz X Schmid; Dietrich E Birnbaum
Journal:  Tissue Eng       Date:  2007-01

Review 7.  Single stage cell seeding of small diameter prosthetic cardiovascular grafts.

Authors:  Nasser Alobaid; Henryk J Salacinski; Kevin M Sales; George Hamilton; Alexander M Seifalian
Journal:  Clin Hemorheol Microcirc       Date:  2005       Impact factor: 2.375

8.  Endothelial seeding of polytetrafluoroethylene femoral popliteal bypasses: the failure of low-density seeding to improve patency.

Authors:  M Herring; J Smith; M Dalsing; J Glover; R Compton; K Etchberger; T Zollinger
Journal:  J Vasc Surg       Date:  1994-10       Impact factor: 4.268

9.  The effect of gradually graded shear stress on the morphological integrity of a huvec-seeded compliant small-diameter vascular graft.

Authors:  Hiroyuki Inoguchi; Takashi Tanaka; Yoshihiko Maehara; Takehisa Matsuda
Journal:  Biomaterials       Date:  2006-10-10       Impact factor: 12.479

10.  The relationship between gestational age and compliance in human umbilical vein and its possible application in vascular grafting.

Authors:  Wenchun Li; Tiezhu Huang; Yanjun Zeng; Zhongjun Yao
Journal:  Ann Vasc Surg       Date:  2006-04-01       Impact factor: 1.466

View more
  3 in total

Review 1.  Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development.

Authors:  Daniel Radke; Wenkai Jia; Dhavan Sharma; Kemin Fena; Guifang Wang; Jeremy Goldman; Feng Zhao
Journal:  Adv Healthc Mater       Date:  2018-05-07       Impact factor: 9.933

2.  The crescendo pulse frequency of shear stress stimulates the endothelialization of bone marrow mesenchymal stem cells on the luminal surface of decellularized scaffold in the bioreactor.

Authors:  Yuhao Jiao; Yuanguo Zhang; Yonghao Xiao; Yuehao Xing; Zhiwen Cai; Cong Wang; Zhengtong Zhou; Zengguo Feng; Yongquan Gu
Journal:  Bioengineered       Date:  2022-03       Impact factor: 6.832

Review 3.  Vascular implants - new aspects for in situ tissue engineering.

Authors:  Cornelia Blume; Xenia Kraus; Sebastian Heene; Sebastian Loewner; Nils Stanislawski; Fabian Cholewa; Holger Blume
Journal:  Eng Life Sci       Date:  2022-01-07       Impact factor: 2.678