Literature DB >> 17034847

The effect of gradually graded shear stress on the morphological integrity of a huvec-seeded compliant small-diameter vascular graft.

Hiroyuki Inoguchi1, Takashi Tanaka, Yoshihiko Maehara, Takehisa Matsuda.   

Abstract

The premature endothelialization of tissue-engineered grafts had often induced cellular detachment at an early period of implantation in arterial circulation, resulting in occlusion at an early period of implantation. This study was aimed to determine whether gradually increased shear stress applied ex vivo improves cell retention and tissue morphological integrity including cell shape and alignment, actin fiber alignment and expression of vascular endothelial (VE) cadherin. Tissue-engineered grafts used for this study were human umbilical vein endothelial cell (HUVEC)-seeded compliant small-diameter grafts made of poly(L-lactide-co-epsilon-caprolactone) fiber meshes fabricated by electrospinning. The shear stresses applied to grafts, generated using a custom-designed mock circulatory apparatus, were 3.2, 8.7 and 19.6 dyn/cm(2). The grafts completely monolayered prior to shear stress exposure exhibited a polygonal cobblestone morphology with randomly distributed actin fibers and VE cadherin at the continuous peripheral region of adjacent cells. The 24-h-loading of high shear stresses (8.7 and 19.6 dyn/cm(2)) equivalent to those of the arterial circulatory system resulted in severe cellular damage resulting in the complete loss of cells. However, a gradually increased graded exposure from a low (3.2 dyn/cm(2)) to a high shear stress (19.6 dyn/cm(2)) resulted in a markedly reduced cell detachment, a highly elongated cell shape, and orientation or alignment of both cells and actin fibers, which were parallel to the direction of flow. Although VE-cadherin expression was not detected yet, a higher degree of tissue integrity was achieved, which may greatly improve the performance particularly at an early period of implantation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17034847     DOI: 10.1016/j.biomaterials.2006.09.020

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  26 in total

1.  Three-dimensional microfluidic collagen hydrogels for investigating flow-mediated tumor-endothelial signaling and vascular organization.

Authors:  Cara F Buchanan; Elizabeth E Voigt; Christopher S Szot; Joseph W Freeman; Pavlos P Vlachos; Marissa Nichole Rylander
Journal:  Tissue Eng Part C Methods       Date:  2013-07-12       Impact factor: 3.056

Review 2.  Cell-seeding techniques in vascular tissue engineering.

Authors:  Gustavo A Villalona; Brooks Udelsman; Daniel R Duncan; Edward McGillicuddy; Rajendra F Sawh-Martinez; Narutoshi Hibino; Christopher Painter; Tamar Mirensky; Benjamin Erickson; Toshiharu Shinoka; Christopher K Breuer
Journal:  Tissue Eng Part B Rev       Date:  2010-06       Impact factor: 6.389

3.  Linear shear conditioning improves vascular graft retention of adipose-derived stem cells by upregulation of the alpha5beta1 integrin.

Authors:  Stephen E McIlhenny; Eric S Hager; Daniel J Grabo; Christopher DiMatteo; Irving M Shapiro; Thomas N Tulenko; Paul J DiMuzio
Journal:  Tissue Eng Part A       Date:  2010-01       Impact factor: 3.845

4.  Physiologically Modeled Pulse Dynamics to Improve Function in In Vitro-Endothelialized Small-Diameter Vascular Grafts.

Authors:  Joseph S Uzarski; Jhon Cores; Peter S McFetridge
Journal:  Tissue Eng Part C Methods       Date:  2015-06-24       Impact factor: 3.056

5.  New Methods in Tissue Engineering: Improved Models for Viral Infection.

Authors:  Vyas Ramanan; Margaret A Scull; Timothy P Sheahan; Charles M Rice; Sangeeta N Bhatia
Journal:  Annu Rev Virol       Date:  2014-11       Impact factor: 10.431

Review 6.  Engineering extracellular matrix through nanotechnology.

Authors:  Cassandra M Kelleher; Joseph P Vacanti
Journal:  J R Soc Interface       Date:  2010-09-22       Impact factor: 4.118

Review 7.  Engineering of arteries in vitro.

Authors:  Angela H Huang; Laura E Niklason
Journal:  Cell Mol Life Sci       Date:  2014-01-08       Impact factor: 9.261

8.  Fabricating Superhydrophobic Polymeric Materials for Biomedical Applications.

Authors:  Jonah Kaplan; Mark Grinstaff
Journal:  J Vis Exp       Date:  2015-08-28       Impact factor: 1.355

9.  Interactions between endothelial cells and electrospun methacrylic terpolymer fibers for engineered vascular replacements.

Authors:  A N Veleva; D E Heath; J K Johnson; J Nam; C Patterson; J J Lannutti; S L Cooper
Journal:  J Biomed Mater Res A       Date:  2009-12-15       Impact factor: 4.396

10.  Human endothelial cells hollow fiber membrane bioreactor as a model of the blood vessel for in vitro studies.

Authors:  Anna Ciechanowska; Piotr Ladyzynski; Grazyna Hoser; Stanislawa Sabalinska; Jerzy Kawiak; Piotr Foltynski; Cezary Wojciechowski; Andrzej Chwojnowski
Journal:  J Artif Organs       Date:  2016-04-30       Impact factor: 1.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.