| Literature DB >> 25996570 |
Oleksiy Buznyk1,2, Nataliya Pasyechnikova1, M Mirazul Islam2,3, Stanislav Iakymenko1, Per Fagerholm2, May Griffith2,3.
Abstract
Corneas with severe pathologies have a high risk of rejection when conventionally grafted with human donor tissues. In this early observational study, we grafted bioengineered corneal implants made from recombinant human collagen and synthetic phosphorylcholine polymer into three patients for whom donor cornea transplantation carried a high risk of transplant failure. These patients suffered from corneal ulcers and recurrent erosions preoperatively. The implants provided relief from pain and discomfort, restored corneal integrity by promoting endogenous regeneration of corneal tissues, and improved vision in two of three patients. Such implants could in the future be alternatives to donor corneas for high-risk patients, and therefore, merits further testing in a clinical trial.Entities:
Keywords: collagen; epithelium; grafting; patients; remodeling; transplantation
Mesh:
Year: 2015 PMID: 25996570 PMCID: PMC4676913 DOI: 10.1111/cts.12293
Source DB: PubMed Journal: Clin Transl Sci ISSN: 1752-8054 Impact factor: 4.689
Figure 1Schematic diagram showing the combination of recombinant human collagen type III (RHCIII) and 2‐methacryloyloxyethyl phosphorylcholine (MPC) to form interpenetrating networks of RHCIII‐MPC. The RHCIII and MPC were mixed together in a syringe, while the final hydrogel was molded into an implant. An image of Vladimir Filatov, pioneer of human donor cornea grafting, can be seen through the transparent implant.
Properties of RHCIII‐MPC hydrogels used as corneal implants
| Properties | Transmission at 500 nm (%) | Backscatter (%) | Refractive index | Tensile strength (MPa) | Elongation (%) | Modulus (MPa) | Denaturation temperature (°C) |
|---|---|---|---|---|---|---|---|
| Implants | 92.1 ± 0.1 | 1.66 ± 0.55 | 1.334 ± 0.000 | 0.26 ± 0.06 | 12.15 ± 0.84 | 3.63 ± 0.84 | 56.96 ± 1.05 |
| Human cornea | 87.1 ± 2.0 | <3 | 1.373–1.380 | 3.81 ± 0.40 |
| 3–13 | 65.1 |
1Doutch J, Quantock AJ, Smith VA, Meek KM. Light transmission in the human cornea as a function of position across the ocular surface: theoretical and experimental aspects. Biophys J. 2008; 95: 5092–5099.
+van den Berg TJ, Tan KE. Light transmittance of the human cornea from 320 to 700 nm for different ages. Vision Res. 1994; 34: 1453–1456.
‡Patel S, Marshall J, Fitzke FW, 3rd. Refractive index of the human corneal epithelium and stroma. J Refract Surg. 1995; 11: 100–105.
§Zeng Y, Yang J, Huang K, Lee Z, Lee X. A comparison of biomechanical properties between human and porcine cornea. J Biomech. 2001; 34: 533–537.
**Crabb RA, Chau EP, Evans MC, Barocas VH, Hubel A. Biomechanical and microstructural characteristics of a collagen film‐based corneal stroma equivalent. Tissue Eng. 2006; 12: 1565–1575.
++Jue B, Maurice DM. The mechanical properties of the rabbit and human cornea. J Biomech. 1986; 19: 847–853.
‡‡Merrett K, Fagerholm P, McLaughlin CR, Dravida S, Lagali N, Shinozaki N, Watsky MA, Munger R, Kato Y, Li F, Marmo CJ, Griffith M. Tissue‐engineered recombinant human collagen‐based corneal substitutes for implantation: performance of type I versus type III collagen. Invest Ophthalmol Vis Sci. 2008; 49: 3887–3894.
Details of implanted patients showing their biometrics, diagnosis, treatment, and results
| No. | Age (years) | Sex | Diagnosis | Time after disease start (months) | Previous surgeries | Graft diameter (mm) | Graft thickness (μm) | Suture removal (weeks after surgery) | Full epithelial coverage (weeks after surgery) | BCVA | BCVA at last follow‐up | Corneal pachymetry of operated eye (μm) before surgery/at last follow‐up | Schirmer test I at last follow‐up operated/fellow nonoperated control (mm/5 min) | IOP of operated eye before surgery/at last follow‐up (mm Hg) | Follow‐up (months) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 80 | M | CU/AlkB | 2 | – | 4 | 250 | 3 | 8 | 6/200 | 6/38 | 550/459 | 12/11 | 21/19 | 12 |
| 2 | 72 | F | CU/PK | 14 | PK + CE + IOL | 4 | 250 | 11 | 8 | LP | 6/75 | 512/447 | 7/6 | 17/19 | 12 |
| 3 | 52 | M | RCE/AcB | 36 | PTK,HAM, Phaco + IOL | 5 | 350 | 2 | 2 | 6/600 | 6/200 | 532/512 | 15+/15+ | 16/18 | 9 |
CU = corneal ulcer; RCE = recurrent corneal erosion; AcB = acid burn; AlkB = alkali burn; PTK = phototherapeutic keratectomy; CE = cataract extraction; IOL = intraocular lens implantation; Phaco = cataract phacoemulsification; HAM = human amniotic membrane transplantation; PK = penetrating keratoplasty; LP = light perception.
*BCVA = best corrected visual acuity (LP, 6/600–6/375: near blindness; 6/300–6/150: profound vision loss; 6/120–6/60: severe vision loss: 6/48–6/24: moderate vision loss; 6/19–6/9.5: mild vision loss; 6/7.5–6/3.8: normal range of vision).
Figure 2Corneas of all three patients before and after implantation with tectonic grafts of RHCIII‐MPC. Patient 1's cornea had an ulcer overlying a vascularized stroma. The green fluorescein staining delineates the large area of eroded epithelium. At 12 months postoperation, the cornea is intact and relatively clear. Patient 2 had a failed 8.5‐mm‐diameter graft with a persistent ulcer and dense stromal opacification in the visual zone prior to surgery. A small 4‐mm implant was grafted into the ulcerated area of the failed graft (arrowhead) and has remained relatively clear after 12 months. Patient 3 had an opacity with an unstable epithelial surface and vascularized stroma prior to surgery. At 9 months postoperation, while the implant remained clear, the ingrowing conjunctiva has left the surface hazy.
Figure 3Restoration of touch sensitivity after grafting with RHCIII‐MPC implants as an indication of nerve function restoration. Central corneal touch sensitivity was assessed by contact esthesiometry in the patients’ corneas before and after implantation, with the nonoperated, contralateral eyes serving as controls. Measurements were obtained using a Cochet–Bonnet esthesiometer with a monofilament, where an increase in filament length (mm) corresponds to an increase in touch sensitivity (n = 3 patients).
Figure 4In vivo confocal microscopy through an implanted cornea at 12 months postoperation showing regenerated patient epithelium (A) that resembles that of a healthy cornea (B). Stromal cells have grown into the initially cell‐free graft, although partially obscured by haze (C), unlike the healthy cornea where the cells are clearly visible (D). The preserved patient endothelium (E) has a number of larger sized cells but also endothelial cells that resemble those of a healthy cornea (F).