Literature DB >> 2599583

In vitro substance loss due to galvanic corrosion in Ti implant/Ni-Cr supraconstruction systems.

J Geis-Gerstorfer, H Weber, K H Sauer.   

Abstract

To characterize the galvanic corrosion of supraconstructions consisting of Ni-Cr alloys that come in contact with titanium implants, the resultant substance loss was determined. The measurement of the released substance masses was conducted by analysis of the electrolyte solutions with the aid of atomic absorption spectrometry and by approximate calculation using current density time curves, according to Faraday's law. The results of this study show that both methods allow a clear differentiation of the corrosion behavior of various Ni-Cr alloys that come in contact with titanium.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2599583

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Comparative evaluation of shear bond strength between titanium-ceramic and cobalt-chromium-ceramic: An in vitro study.

Authors:  Kamal Ramjee Vaska; Chandrasekhar Nakka; K Mahendranath Reddy; Siddesh Kumar Chintalapudi
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

Review 2.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

3.  Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity.

Authors:  Jung-Jin Lee; Kwang-Yeob Song; Seung-Geun Ahn; Jung-Yun Choi; Jae-Min Seo; Ju-Mi Park
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

4.  Electrochemical Behaviour and Galvanic Effects of Titanium Implants Coupled to Metallic Suprastructures in Artificial Saliva.

Authors:  Ana Mellado-Valero; Anna Igual Muñoz; Virginia Guiñón Pina; Ma Fernanda Sola-Ruiz
Journal:  Materials (Basel)       Date:  2018-01-22       Impact factor: 3.623

5.  The electrochemical properties of four dental casting suprastructure alloys coupled with titanium implants.

Authors:  Suleyman Hakan Tuna; Nuran Ozcicek Pekmez; Filiz Keyf; Fulya Canli
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

6.  A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry.

Authors:  Sammy Noumbissi; Antonio Scarano; Saurabh Gupta
Journal:  Materials (Basel)       Date:  2019-01-24       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.