Kamal Ramjee Vaska1, Chandrasekhar Nakka2, K Mahendranath Reddy3, Siddesh Kumar Chintalapudi4.
Abstract
Aim: The aim of this study was to evaluate and compare the shear bond strength between ceramic layered over titanium and ceramic layered over cobalt-chromium alloy, which are used in the fabrication of screw-retained implant prosthesis. Settings and Design: In-vitro - Comparative study. Materials and Method: A total of 40 samples (20 samples of Titanium in Group 1 and 20 samples of Cobalt-Chromium in Group 2) were fabricated. For all the samples bonding agent was applied on to the sand blasted surface and firing was done at a temperature of 980° C. A layer of opaque was applied using a brush and placed back in the furnace at a temperature of 910° C. Then ceramic was layered on to the surface with putty index as guide and firing was done in the ceramic furnace up to a temperature of 880° C followed by glazing. Shear bond strength was measured using a Universal Testing Machine. Statistical Analyses Used: One sample t-test and paired sample t-test.Entities:
Keywords: Cobalt-chromium; porcelain; shear bond strength; titanium
Mesh:
Substances:
Year: 2021 PMID: 34380815 PMCID: PMC8425371 DOI: 10.4103/jips.jips_81_21
Source DB: PubMed Journal: J Indian Prosthodont Soc ISSN: 0972-4052
Figure 1Brass die 2 mm × 2 mm × 10 mm
Figure 2Samples
Figure 3Wax patterns for cobalt chromium sample fabrication
Figure 4Scanning electron microscope image of cobalt-chromium ceramic specimen
Mean values of samples from two groups
| Metal types |
| Minimum | Maximum | Mean | SD |
|---|---|---|---|---|---|
| Co-Cr | 20 | 6.65 | 51.38 | 23.9125 | 10.5120 |
| Titanium | 20 | 12.20 | 72.09 | 29.7515 | 14.7082 |
SD: Standard deviation, Co-Cr: Cobalt-chromium alloy
One-sample t-test showing the mean difference of the samples from two groups
| Metal types |
| df |
| 95% CI (lower bound-upper bound) |
|---|---|---|---|---|
| Co-Cr | 10.173 | 19 | <0.001 | 18.992-28.832 |
| Titanium | 9.046 | 19 | <0.001 | 22.867-36.635 |
Co-Cr: Cobalt-chromium alloy, CI: Confidence interval
Paired-sample t-test showing the mean difference of the samples from two groups
| Metal types | Mean | SD | SEM | 95% CI (lower-upper) |
| df |
|
|---|---|---|---|---|---|---|---|
| Co-Cr versus titanium | −5.839 | 17.9738 | 4.01907 | −14.251-2.573 | −1.453 | 19 | 0.163 |
Co-Cr: Cobalt-chromium alloy, CI: Confidence interval, SD: Standard deviation, SEM: Standard error of mean
Figure 5Universal testing machine
Figure 6Scanning electron microscope image of Ti-ceramic specimen