Literature DB >> 25994690

Passive acoustic mapping utilizing optimal beamforming in ultrasound therapy monitoring.

Christian Coviello1, Richard Kozick2, James Choi3, Miklós Gyöngy4, Carl Jensen1, Penny Probert Smith1, Constantin-C Coussios1.   

Abstract

Passive acoustic mapping (PAM) is a promising imaging method that enables real-time three-dimensional monitoring of ultrasound therapy through the reconstruction of acoustic emissions passively received on an array of ultrasonic sensors. A passive beamforming method is presented that provides greatly improved spatial accuracy over the conventionally used time exposure acoustics (TEA) PAM reconstruction algorithm. Both the Capon beamformer and the robust Capon beamformer (RCB) for PAM are suggested as methods to reduce interference artifacts and improve resolution, which has been one of the experimental issues previously observed with TEA. Simulation results that replicate the experimental artifacts are shown to suggest that bubble interactions are the chief cause. Analysis is provided to show that these multiple bubble artifacts are generally not reduced by TEA, while Capon-based methods are able to reduce the artifacts. This is followed by experimental results from in vitro experiments and in vivo oncolytic viral therapy trials that show improved results in PAM, where RCB is able to more accurately localize the acoustic activity than TEA.

Entities:  

Year:  2015        PMID: 25994690     DOI: 10.1121/1.4916694

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  35 in total

1.  Efficacy of histotripsy combined with rt-PA in vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Himanshu Shekhar; Adam D Maxwell; Tao Peng; David D McPherson; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

2.  Pulse inversion enhances the passive mapping of microbubble-based ultrasound therapy.

Authors:  Antonios N Pouliopoulos; Mark T Burgess; Elisa E Konofagou
Journal:  Appl Phys Lett       Date:  2018-07-24       Impact factor: 3.791

3.  Frequency-sum beamforming for passive cavitation imaging.

Authors:  Shima H Abadi; Kevin J Haworth; Karla P Mercado-Shekhar; David R Dowling
Journal:  J Acoust Soc Am       Date:  2018-07       Impact factor: 1.840

Review 4.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

5.  Post Hoc Analysis of Passive Cavitation Imaging for Classification of Histotripsy-Induced Liquefaction in Vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Adam D Maxwell; Christy K Holland
Journal:  IEEE Trans Med Imaging       Date:  2017-08-02       Impact factor: 10.048

6.  A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

Authors:  Lulu Deng; Meaghan A O'Reilly; Ryan M Jones; Ran An; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

7.  Combined passive acoustic mapping and magnetic resonance thermometry for monitoring phase-shift nanoemulsion enhanced focused ultrasound therapy.

Authors:  Calum Crake; F Can Meral; Mark T Burgess; Iason T Papademetriou; Nathan J McDannold; Tyrone M Porter
Journal:  Phys Med Biol       Date:  2017-07-13       Impact factor: 3.609

8.  Closed Loop Spatial and Temporal Control of Cavitation Activity with Passive Acoustic Mapping.

Authors:  Arpit Patel; Scott J Schoen; Costas D Arvanitis
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-20       Impact factor: 4.538

9.  Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.

Authors:  M T Burgess; I Apostolakis; E E Konofagou
Journal:  Phys Med Biol       Date:  2018-03-15       Impact factor: 3.609

10.  A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device.

Authors:  Calum Crake; Spencer T Brinker; Christian M Coviello; Margaret S Livingstone; Nathan J McDannold
Journal:  Phys Med Biol       Date:  2018-03-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.