Literature DB >> 25984928

Setup error and motion during deep inspiration breath-hold breast radiotherapy measured with continuous portal imaging.

Christina Maria Lutz1, Per Rugaard Poulsen2,3, Walther Fledelius3, Birgitte Vrou Offersen2,3, Mette Skovhus Thomsen1.   

Abstract

BACKGROUND: The position and residual motion of the chest wall of breast cancer patients during treatment in deep inspiration breath-hold (DIBH) were investigated.
MATERIAL AND METHODS: The study included 58 left-sided breast cancer patients treated with DIBH three-dimensional (3D) conformal radiotherapy in 15 or 25 fractions. The DIBH levels were monitored using an external marker block placed on the chest, either shifted 5 cm to the right at the level of the xiphoid process (Group 1, 27 consecutive patients) or placed medially on the inferior part of the sternum (Group 2, 31 consecutive patients). At every third treatment fraction, continuous portal images were acquired. The time-resolved chest wall position during treatment was compared with the planned position to determine the inter-fraction setup errors and the intra-fraction motion of the chest wall.
RESULTS: The DIBH compliance was 95% during both recruitment periods. A tendency of smaller inter-fraction setup errors and intra-fraction motion was observed for group 2 (medial marker block position). However, apart from a significantly reduced inter-field random shift (σ = 1.7 mm vs. σ = 0.9 mm, p = 0.005), no statistically significant differences between the groups were found. In a combined analysis, the group mean inter-fraction setup error was M = - 0.1 mm, with random and systematic errors of σ = 1.7 mm and Σ = 1.4 mm. The group mean inter-field shift was M = 0.0 (σ = 1.3 mm and Σ = 1.1 mm) and the group mean standard deviation of the intra-field motion was 0.5 mm. The absolute setup error had a maximum of 16.3 mm, exceeding 5 mm in 2.2% of the imaged fields.
CONCLUSION: Compared to free breathing treatments, the primary benefit of the DIBH technique was the separation of the heart from the target rather than more accurate targeting. Despite a small gating window, occasional large errors in the chest wall position were observed for some patients, illustrating limitations of the external marker block as surrogate in a broad patient population.

Entities:  

Mesh:

Year:  2015        PMID: 25984928     DOI: 10.3109/0284186X.2015.1045625

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  11 in total

1.  Reproducibility of Deep-Inspiration Breath Hold treatments on Halcyon™ performed using the first clinical version of AlignRT InBore™: Results of CYBORE study.

Authors:  F Lorchel; D Nguyen; A Mamou; N Barbet; J Camoesas; Y Degluaire; I Pouchard; Y Queffelec; F Renoult; M Khodri; J Farah
Journal:  Clin Transl Radiat Oncol       Date:  2022-05-18

2.  A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy.

Authors:  Peng-Yi Lee; Chih-Yuan Lin; Shang-Wen Chen; Chun-Ru Chien; Chun-Nan Chu; Hsiu-Ting Hsu; Ji-An Liang; Ying-Jun Lin; An-Cheng Shiau
Journal:  Radiat Oncol       Date:  2017-03-20       Impact factor: 3.481

3.  AlignRT® and Catalyst™ in whole-breast radiotherapy with DIBH: Is IGRT still needed?

Authors:  Marko Laaksomaa; Sebastian Sarudis; Maija Rossi; Turkka Lehtonen; Jani Pehkonen; Jenny Remes; Helmi Luukkanen; Tanja Skyttä; Mika Kapanen
Journal:  J Appl Clin Med Phys       Date:  2019-03       Impact factor: 2.102

4.  Continuous breath-hold assessment during breast radiotherapy using portal imaging.

Authors:  Marcus Doebrich; Janine Downie; Joerg Lehmann
Journal:  Phys Imaging Radiat Oncol       Date:  2018-03-08

5.  Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer.

Authors:  Sunmin Park; Chai Hong Rim; Won Sup Yoon
Journal:  Radiat Oncol       Date:  2021-04-20       Impact factor: 3.481

6.  Effectiveness of individual audio-visual coaching, respiratory modulated stereotactic body radiotherapy for localized hepatocellular carcinoma: Analysis of 29 cases from a single academic radiotherapy center.

Authors:  Liang-Cheng Chen; Hon-Yi Lin; Moon-Sing Lee; Wen-Yen Chiou; Li-Wen Huang; Chia-Hui Chew; Feng-Chun Hsu; Shih-Kai Hung
Journal:  Tzu Chi Med J       Date:  2021-04-26

7.  A system for real-time monitoring of breath-hold via assessment of internal anatomy in tangential breast radiotherapy.

Authors:  Elena N Vasina; Peter Greer; David Thwaites; Tomas Kron; Joerg Lehmann
Journal:  J Appl Clin Med Phys       Date:  2021-11-18       Impact factor: 2.102

8.  Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience.

Authors:  Joan Penninkhof; Kimm Fremeijer; Kirsten Offereins-van Harten; Cynthia van Wanrooij; Sandra Quint; Britt Kunnen; Nienke Hoffmans-Holtzer; Annemarie Swaak; Margreet Baaijens; Maarten Dirkx
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-02-17

9.  Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.

Authors:  Edy Ippolito; Michele Fiore; Alessia Di Donato; Sonia Silipigni; Carla Rinaldi; Patrizia Cornacchione; Erminia Infusino; Cristina Di Venanzio; Carlo Greco; Lucio Trodella; Sara Ramella; Rolando Maria D'Angelillo
Journal:  PLoS One       Date:  2018-05-10       Impact factor: 3.240

10.  Target position reproducibility in left-breast irradiation with deep inspiration breath-hold using multiple optical surface control points.

Authors:  Aurora Fassi; Giovanni B Ivaldi; Paola Tabarelli de Fatis; Marco Liotta; Ilaria Meaglia; Patrizia Porcu; Lea Regolo; Marco Riboldi; Guido Baroni
Journal:  J Appl Clin Med Phys       Date:  2018-05-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.