Literature DB >> 25976128

Preparation and characterization of tentacle-type polymer stationary phase modified with graphene oxide for open-tubular capillary electrochromatography.

Xing Gao1, Rongzhen Mo1, Yibing Ji2.   

Abstract

In this research, a novel organic polymer coated stationary phase modified with inorganic nanomaterial was prepared for open-tubular capillary electrochromatography (OT-CEC). The capillary was developed by covalent attaching graphene oxide (GO) onto the tentacle-type polymer chains grafted capillary which was derivatized with ammonium hydroxide. Scanning electron microscopy (SEM) and Raman spectroscopy provided evidences that the tentacle-type polymer and GO were coated to the capillary inner wall. This novel GO-polymer modified capillary column generated a strong and stable electroosmotic flow (EOF) from anode to cathode with the running electrolytes of pH ranging from 4.0 to 9.0, and showed excellent separation ability toward neutral small molecules, amino acids and ephedrine-pseudoephedrine isomers with resolution higher than 2.30 and column efficiency up to over 170,000 plates/m. The repeatabilities of the GO-GMA@capillary were satisfying with relative standard deviations for intra-day and inter-day runs less than 3.27%, and column-to-column runs less than 7.49%. Additionally, the separation performance of GO-polymer modified capillary was compared with that of the polymer coated capillary and GO coated capillary.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amino acids; Graphene oxide; Open-tubular capillary electrochromatogrphy; Tentacle-type polymer

Mesh:

Substances:

Year:  2015        PMID: 25976128     DOI: 10.1016/j.chroma.2015.04.039

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Graphene oxide as a stationary phase for speciation of inorganic and organic species of mercury, arsenic and selenium using HPLC with ICP-MS detection.

Authors:  Heyong Cheng; Wenwen Zhang; Yuanchao Wang; Jinhua Liu
Journal:  Mikrochim Acta       Date:  2018-08-22       Impact factor: 5.833

2.  Maltodextrin-modified graphene oxide for improved enantiomeric separation of six basic chiral drugs by open-tubular capillary electrochromatography.

Authors:  Mingxuan Ma; Ying Xi; Yingxiang Du; Jiangxia Yang; Xiaofei Ma; Cheng Chen
Journal:  Mikrochim Acta       Date:  2019-12-17       Impact factor: 5.833

3.  Gold nanoparticles coated with a tetramethylammonium lactobionate ionic liquid for enhanced chiral differentiation in open tubular capillary electrochromatography: application to enantioseparation of β-blockers.

Authors:  Xiaodong Sun; Cheng Chen; Xiaoqi Li; Yingxiang Du; Shiyuan Zhao; Zijie Feng
Journal:  Mikrochim Acta       Date:  2020-02-14       Impact factor: 5.833

4.  Enantioseparation of propranolol, amlodipine and metoprolol by electrochromatography using an open tubular capillary modified with β-cyclodextrin and poly(glycidyl methacrylate) nanoparticles.

Authors:  Xiaodong Sun; Yingxiang Du; Shiyuan Zhao; Zhifeng Huang; Zijie Feng
Journal:  Mikrochim Acta       Date:  2019-01-29       Impact factor: 5.833

5.  An organic polymer monolith modified with an amino acid ionic liquid and graphene oxide for use in capillary electrochromatography: application to the separation of amino acids, β-blockers, and nucleotides.

Authors:  Shiyuan Zhao; Tao Yu; Yingxiang Du; Xiaodong Sun; Zijie Feng; Xiaofei Ma; Wen Ding; Cheng Chen
Journal:  Mikrochim Acta       Date:  2019-08-20       Impact factor: 5.833

6.  MIL-53-based homochiral metal-organic framework as a stationary phase for open-tubular capillary electrochromatography.

Authors:  Xiaodong Sun; Bing Niu; Qi Zhang; Qin Chen
Journal:  J Pharm Anal       Date:  2021-12-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.