Literature DB >> 25975352

A field camera for MR sequence monitoring and system analysis.

Benjamin E Dietrich1, David O Brunner1,2, Bertram J Wilm1,2, Christoph Barmet1,2, Simon Gross1, Lars Kasper1,3, Maximilian Haeberlin1, Thomas Schmid1, S Johanna Vannesjo1, Klaas P Pruessmann1.   

Abstract

PURPOSE: MR image formation and interpretation relies on highly accurate dynamic magnetic fields of high fidelity. A range of mechanisms still limit magnetic field fidelity, including magnet drifts, eddy currents, and finite linearity and stability of power amplifiers used to drive gradient and shim coils. Addressing remaining errors by means of hardware, sequence, or signal processing optimizations, calls for immediate observation by magnetic field monitoring. The present work presents a stand-alone monitoring system delivering insight into such field imperfections for MR sequence and system analysis.
METHODS: A flexible NMR field probe-based stand-alone monitoring system, built on a software-defined-radio approach, is introduced and used to sense field dynamics up to third-order in space in a selection of situations with different time scales.
RESULTS: Highly sensitive trajectories are measured and successfully used for image reconstruction. Further field perturbations due to mechanical oscillations and thermal field drifts following demanding gradient use and external interferences are studied.
CONCLUSION: A flexible and versatile monitoring system is presented, delivering camera-like access to otherwise hardly accessible field dynamics with nanotesla resolution. Its stand-alone nature enables field analysis even during unknown MR system states.
© 2015 Wiley Periodicals, Inc.

Keywords:  field camera; field drifts; gradient vibrations; gradients; hardware; magnetic field monitoring; monitoring; scanner cool-down; stand-alone; trajectories

Mesh:

Year:  2015        PMID: 25975352     DOI: 10.1002/mrm.25770

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  A Wireless Radio Frequency Triggered Acquisition Device (WRAD) for Self-Synchronised Measurements of the Rate of Change of the MRI Gradient Vector Field for Motion Tracking.

Authors:  Adam van Niekerk; Ernesta Meintjes; Andre van der Kouwe
Journal:  IEEE Trans Med Imaging       Date:  2019-01-10       Impact factor: 10.048

2.  Inductive measurement and encoding of k-space trajectories in MR raw data.

Authors:  Jan Ole Pedersen; Christian G Hanson; Rong Xue; Lars G Hanson
Journal:  MAGMA       Date:  2019-07-30       Impact factor: 2.310

3.  Magnetization-prepared shells trajectory with automated gradient waveform design.

Authors:  Yunhong Shu; Shengzhen Tao; Joshua D Trzasko; John Huston; Paul T Weavers; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

Review 4.  Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome.

Authors:  Susie Y Huang; Thomas Witzel; Boris Keil; Alina Scholz; Mathias Davids; Peter Dietz; Elmar Rummert; Rebecca Ramb; John E Kirsch; Anastasia Yendiki; Qiuyun Fan; Qiyuan Tian; Gabriel Ramos-Llordén; Hong-Hsi Lee; Aapo Nummenmaa; Berkin Bilgic; Kawin Setsompop; Fuyixue Wang; Alexandru V Avram; Michal Komlosh; Dan Benjamini; Kulam Najmudeen Magdoom; Sudhir Pathak; Walter Schneider; Dmitry S Novikov; Els Fieremans; Slimane Tounekti; Choukri Mekkaoui; Jean Augustinack; Daniel Berger; Alexander Shapson-Coe; Jeff Lichtman; Peter J Basser; Lawrence L Wald; Bruce R Rosen
Journal:  Neuroimage       Date:  2021-08-28       Impact factor: 7.400

Review 5.  Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact.

Authors:  Qiuyun Fan; Cornelius Eichner; Maryam Afzali; Lars Mueller; Chantal M W Tax; Mathias Davids; Mirsad Mahmutovic; Boris Keil; Berkin Bilgic; Kawin Setsompop; Hong-Hsi Lee; Qiyuan Tian; Chiara Maffei; Gabriel Ramos-Llordén; Aapo Nummenmaa; Thomas Witzel; Anastasia Yendiki; Yi-Qiao Song; Chu-Chung Huang; Ching-Po Lin; Nikolaus Weiskopf; Alfred Anwander; Derek K Jones; Bruce R Rosen; Lawrence L Wald; Susie Y Huang
Journal:  Neuroimage       Date:  2022-02-23       Impact factor: 7.400

6.  The effect of spiral trajectory correction on pseudo-continuous arterial spin labeling with high-performance gradients on a compact 3T scanner.

Authors:  Daehun Kang; Uten Yarach; Myung-Ho In; Erin M Gray; Joshua D Trzasko; Hang Joon Jo; Yunhong Shu; John Huston; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2019-12-04       Impact factor: 4.668

7.  An MRI-based switched gradient impulse response characterization method with uniform eigenmode excitation.

Authors:  Kulam Najmudeen Magdoom; Malisa Sarntinoranont; Thomas H Mareci
Journal:  J Magn Reson       Date:  2020-03-17       Impact factor: 2.229

8.  Motion correction methods for MRS: experts' consensus recommendations.

Authors:  Ovidiu C Andronesi; Pallab K Bhattacharyya; Wolfgang Bogner; In-Young Choi; Aaron T Hess; Phil Lee; Ernesta M Meintjes; M Dylan Tisdall; Maxim Zaitzev; André van der Kouwe
Journal:  NMR Biomed       Date:  2020-07-20       Impact factor: 4.044

9.  HYFI: Hybrid filling of the dead-time gap for faster zero echo time imaging.

Authors:  Romain Froidevaux; Markus Weiger; Manuela B Rösler; David O Brunner; Klaas P Pruessmann
Journal:  NMR Biomed       Date:  2021-02-23       Impact factor: 4.044

10.  A plug-and-play, lightweight, single-axis gradient insert design for increasing spatiotemporal resolution in echo planar imaging-based brain imaging.

Authors:  Edwin Versteeg; Tijl A van der Velden; Carel C van Leeuwen; Martino Borgo; Erik R Huijing; Arjan D Hendriks; Jeroen Hendrikse; Dennis W J Klomp; Jeroen C W Siero
Journal:  NMR Biomed       Date:  2021-02-22       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.