Literature DB >> 25973599

Clinical Predictors of Pacemaker Implantation in Patients with Syncope Receiving Implantable Loop Recorder with or without ECG Conduction Abnormalities.

Nauman Ahmed1, Antonio Frontera1, Alexander Carpenter1, Stafenia Cataldo1, Georgia M Connolly1, Matteo Fasiolo2, Tim Cripps1, Glyn Thomas1, Ihab Diab1, Edward R Duncan1.   

Abstract

BACKGROUND: Implantable loop recorders (ILR) allow prolonged cardiac rhythm monitoring and improved diagnostic yield in syncope patients. Predictive factors for pacemaker (PM) implantation in the ILR population with unexplained syncope have not been adequately investigated. In this single center, retrospective, observational study we investigated factors that predict PM implantation in this population.
METHODS: We retrospectively analyzed our ILR database of patients aged over 18 years who underwent ILR implantation for unexplained syncope between January 2009 and June 2013. Patient case notes were examined for demographics, history, electrocardiogram (ECG) abnormalities, investigations, and events during follow-up. The primary end-point was the detection of a symptomatic or asymptomatic bradycardia requiring PM implantation.
RESULTS: During a period of 4.5 years, 200 patients were implanted with ILR for unexplained syncope, of who n = 33 (16.5%) had clinically significant bradycardia requiring PM implantation. After multivariable analysis, history of injury secondary to syncope was found to be the strongest independent predictor for PM implantation (odds ratio [OR]:9.1; P < 0.001; 95% confidence interval [CI]: (3.26-26.81). Other significant predictors included female sex, PR interval > 200msec, and age >75 years. In patients without conduction abnormalities on the ECG, history of injury secondary to syncope was found to be the strongest independent predictor for PM implantation (OR: 8.16; P = 0.00027; 95% [CI]: (2.67-26.27).
CONCLUSIONS: A history of injury secondary to syncope and female sex were independent predictive factors for bradycardia necessitating PM implantation in patients receiving an ILR for syncope with or without ECG conduction abnormalities.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  implantable loop recorder; pacemaker; syncope

Mesh:

Year:  2015        PMID: 25973599     DOI: 10.1111/pace.12666

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  9 in total

1.  Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center.

Authors:  Inês Silveira; Maria João Sousa; Nuno Antunes; Vânia Silva; Carla Roque; António Pinheiro-Vieira; Vítor Lagarto; António Hipólito-Reis; André Luz; Severo Torres
Journal:  J Atr Fibrillation       Date:  2016-08-31

2.  Ajmaline Challenge To Unmask Infrahisian Disease In Patients With Recurrent And Unexplained Syncope, Preserved Ejection Fraction, With Or Without Conduction Abnormalities On Surface ECG.

Authors:  Francesco Pentimalli; Luca Bacino; Matteo Ghione; Siri Giambattista; Massimo Gazzarata; Paolo Bellotti
Journal:  J Atr Fibrillation       Date:  2016-08-31

3.  Clinical characteristics associated with bradycardia and asystole in patients with syncope undergoing long-term electrocardiographic monitoring with implantable loop recorder.

Authors:  Peter Mitro; Miloš Šimurda; Ervin Müller
Journal:  Wien Klin Wochenschr       Date:  2017-04-27       Impact factor: 1.704

4.  Implantable loop recorders in patients with unexplained syncope: Clinical predictors of pacemaker implantation.

Authors:  Martin Huemer; Ann-Kristin Becker; Alexander Wutzler; Philipp Attanasio; Abdul S Parwani; Philipp Lacour; Leif-Hendrik Boldt; Burkert Pieske; Wilhelm Haverkamp; Florian Blaschke
Journal:  Cardiol J       Date:  2018-02-05       Impact factor: 2.737

5.  Permanent pacemaker implantation in unexplained syncope patients with borderline sinus bradycardia and electrophysiology study-proven sinus node disease.

Authors:  Ioannis Doundoulakis; Konstantinos A Gatzoulis; Petros Arsenos; Polychronis Dilaveris; Ioannis Skiadas; Dimitrios Tsiachris; Christos-Konstantinos Antoniou; Stergios Soulaidopoulos; George Karystinos; Voula Pylarinou; Maria Drakopoulou; Skevos Sideris; Charalambos Vlachopoulos; Dimitrios Tousoulis
Journal:  J Arrhythm       Date:  2020-11-22

6.  Clinical predictors for bradycardia and supraventricular tachycardia necessitating therapy in patients with unexplained syncope monitored by insertable cardiac monitor.

Authors:  Tatsuya Onuki; Makoto Shoji; Hiroto Sugiyama; Shuhei Arai; Kosuke Yoshikawa; Hiroshi Mase; Masaaki Kurata; Miwa Kikuchi; Daisuke Wakatsuki; Taku Asano; Hiroshi Suzuki; Kaoru Tanno; Youichi Kobayashi; Toshiro Shinke
Journal:  Clin Cardiol       Date:  2021-03-16       Impact factor: 2.882

7.  Sex-Related Differences in Patients With Unexplained Syncope and Bundle Branch Block: Lower Risk of AV Block and Lesser Need for Cardiac Pacing in Women.

Authors:  Jaume Francisco-Pascual; Nuria Rivas-Gándara; Montserrat Bach-Oller; Clara Badia-Molins; Manel Maymi-Ballesteros; Begoña Benito; Jordi Pérez-Rodon; Alba Santos-Ortega; Antonia Sambola-Ayala; Ivo Roca-Luque; Javier Cantalapiedra-Romero; Jesús Rodríguez-Silva; Gabriel Pascual-González; Àngel Moya-Mitjans; Ignacio Ferreira-González
Journal:  Front Cardiovasc Med       Date:  2022-02-25

8.  Value of Implantable Loop Recorders in Monitoring Efficacy of Radiofrequency Catheter Ablation in Atrial Fibrillation.

Authors:  Ping Yang; Lijin Pu; Liuqing Yang; Fang Li; Zhiling Luo; Tao Guo; Baotong Hua; Shumin Li
Journal:  Med Sci Monit       Date:  2016-08-12

9.  Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations.

Authors:  Nikola N Radovanović; Siniša U Pavlović; Bratislav Kirćanski; Nemanja Branković; Nikola Vujadinović; Vojislav Sajić; Ana Milašinović; Vesna Bisenić; Mirjana Živković; Goran Milašinović
Journal:  Ann Noninvasive Electrocardiol       Date:  2021-06-07       Impact factor: 1.468

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.