Abstract

BACKGROUND: The aim of this retrospective single center cohort study was to assess the occurrence of bradycardia during implantable loop recorder (ILR) monitoring in patients with unexplained syncope and negative conventional testing and to identify clinical predictors of bradycardia and pacemaker implantation.
METHODS: An ILR was implanted in 112 patients (31 men, 81 women, mean age 64 ±13 years) with syncope which was not explained after conventional diagnostic work-up. Clinical variables were compared between patients with and without pacemaker implantation.
RESULTS: A diagnosis was made in 67 patients (60%), including non-arrhythmic (vasodepressor) syncope (27 patients), sinus bradycardia or asystole (23 patients), atrioventricular (AV) block (14 patients) and bradycardic atrial fibrillation (3 patients). The mean time to diagnosis was 233 ± 282 days. A pacemaker was implanted in 40 patients (36%). Male gender, age above 65 years, hypertension, presence of structural heart disease, absence of prodromal symptoms, trauma secondary to syncope, asymptomatic sinus bradycardia and first-degree AV block were clinical predictors of pacemaker implantation in univariate analysis. Of the independent predictive factors three remained significant in multivariate analysis: absence of prodromal symptoms before the loss of consciousness (odds ratio OR 3.38, p = 0.01, 95% confidence interval CI 1.24-9.20), male gender (OR 3.22, p = 0.01, 95% CI 1.26-8.20) and age >65 years (OR 2.94, p = 0.02, 95% CI 1.14-8.33).
CONCLUSIONS: In patients undergoing ILR implantation bradycardia is a frequent finding despite the negative conventional diagnostic testing. Absence of prodromal symptoms, male gender and age >65 years are risk factors for bradycardia and pacemaker implantation.

Entities:  

Keywords:  Arrhythmias; Diagnosis; Implantable loop recorder; Pacemaker; Syncope

Mesh:

Year:  2017        PMID: 28451840     DOI: 10.1007/s00508-017-1197-8

Source DB:  PubMed          Journal:  Wien Klin Wochenschr        ISSN: 0043-5325            Impact factor:   1.704


  24 in total

1.  Implantable loop recorder allows an etiologic diagnosis in one-third of patients. Results of the Spanish reveal registry.

Authors:  Francisco J Lacunza-Ruiz; Angel Moya-Mitjans; Jesús Martínez-Alday; Gonzalo Barón-Esquivias; Ricardo Ruiz-Granell; Nuria Rivas-Gándara; Susana González-Enríquez; Juan Leal-del-Ojo; María F Arcocha-Torres; Julian Pérez-Villacastín; Natalie Garcia-Heil; Arcadi García-Alberola
Journal:  Circ J       Date:  2013-07-20       Impact factor: 2.993

2.  Effectiveness and safety of remote monitoring of patients with an implantable loop recorder.

Authors:  Yasmín Drak-Hernández; Jorge Toquero-Ramos; José M Fernández; Elena Pérez-Pereira; Víctor Castro-Urda; Ignacio Fernández-Lozano
Journal:  Rev Esp Cardiol (Engl Ed)       Date:  2013-11-07

3.  Clinical impact of the implantable loop recorder in patients with isolated syncope, bundle branch block and negative workup: a randomized multicentre prospective study.

Authors:  Antoine Da Costa; Pascal Defaye; Cécile Romeyer-Bouchard; Frédéric Roche; Virginie Dauphinot; Jean-Claude Deharo; Peggy Jacon; Dominique Lamaison; Jean-Claude Bathélemy; Karl Isaaz; Gabriel Laurent
Journal:  Arch Cardiovasc Dis       Date:  2013-02-23       Impact factor: 2.340

4.  The diagnostic yield from implantable loop recorders in children and young adults.

Authors:  N Sreeram; M Gass; C Apitz; G Ziemer; M Hofbeck; M Emmel; K Brockmeier; F Hitchcock; G Bennink
Journal:  Clin Res Cardiol       Date:  2007-12-24       Impact factor: 5.460

5.  Development and prospective validation of a risk stratification system for patients with syncope in the emergency department: the OESIL risk score.

Authors:  Furio Colivicchi; Fabrizio Ammirati; Domenico Melina; Vincenzo Guido; Giuseppe Imperoli; Massimo Santini
Journal:  Eur Heart J       Date:  2003-05       Impact factor: 29.983

6.  Predictive factors for pacemaker implantation in patients receiving an implantable loop recorder for syncope remained unexplained after an extensive cardiac and neurological workup.

Authors:  Pietro Palmisano; Michele Accogli; Maria Zaccaria; Giovanni Luzzi; Frida Nacci; Matteo Anaclerio; Stefano Favale
Journal:  Int J Cardiol       Date:  2013-05-20       Impact factor: 4.164

7.  Long-term cardiac monitoring in older adults with unexplained falls and syncope.

Authors:  Jaspreet Bhangu; C Geraldine McMahon; Patricia Hall; Kathleen Bennett; Ciara Rice; Peter Crean; Richard Sutton; Rose-Anne Kenny
Journal:  Heart       Date:  2016-01-28       Impact factor: 5.994

8.  Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry.

Authors:  Nils Edvardsson; Viveka Frykman; Rob van Mechelen; Peter Mitro; Afsaneh Mohii-Oskarsson; Jean-Luc Pasquié; Hemanth Ramanna; Frank Schwertfeger; Rodolfo Ventura; Despina Voulgaraki; Claudio Garutti; Pelle Stolt; Nicholas J Linker
Journal:  Europace       Date:  2010-11-19       Impact factor: 5.214

9.  External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study.

Authors:  E T Locati; A Moya; M Oliveira; H Tanner; R Willems; M Lunati; M Brignole
Journal:  Europace       Date:  2015-10-29       Impact factor: 5.214

10.  Clinical symptoms associated with asystolic or bradycardic responses on implantable loop recorder monitoring in patients with recurrent syncope.

Authors:  Khalil Kanjwal; Yousuf Kanjwal; Beverly Karabin; Blair P Grubb
Journal:  Int J Med Sci       Date:  2009-04-09       Impact factor: 3.738