Literature DB >> 25970703

Selection of HBsAg-Specific DNA Aptamers Based on Carboxylated Magnetic Nanoparticles and Their Application in the Rapid and Simple Detection of Hepatitis B Virus Infection.

Zhijiang Xi1,2, Rongrong Huang1, Zhiyang Li1, Nongyue He1,3, Ting Wang1, Enben Su1,4, Yan Deng1,3.   

Abstract

Aptamers are short single-stranded DNA or RNA oligonucleotides and can be selected from synthetic combinatorial libraries in vitro. They have a high binding affinity and specificity for their targets. Agarose gels, nitrocellulose membranes, and adsorptive microplates are often used as carriers to immobilize targets in the SELEX (systematic evolution of ligands by exponential enrichment) process, but the subsequent separation step is tedious and time-consuming. Therefore, we used magnetic nanoparticles (MNPs) as carriers to immobilize the target, hepatitis B surface antigen (HBsAg), which is convenient for fast magnetic separation. In this study, we first selected DNA aptamers against HBsAg by immobilizing HBsAg on the surface of carboxylated MNPs. The ssDNA library of each selection round was prepared by asymmetric PCR amplification for the next selection round. To obtain aptamer sequences, the final selected products were purified by gel electrophoresis, then cloned, and sequenced. DNA aptamers that specifically bind to HBsAg were successfully obtained after 13 selection rounds. The selected aptamers were used to construct a chemiluminescence aptasensor based on magnetic separation and immunoassay to detect HBsAg from pure protein or actual serum samples. There was a linear relationship between HBsAg concentration and chemiluminescent intensity in the range of 1-200 ng/mL. The aptasensor worked well even in the presence of interfering substances and was highly specific in the detection of HBsAg in serum samples, with a detection limit 0.1 ng/mL lower than the 0.5 ng/mL limit of an ELISA in use at the hospital. This aptasensor can contribute to better detection of hepatitis B virus infection.

Entities:  

Keywords:  HBsAg; SELEX; aptamers; carboxylated magnetic nanoparticles; detection; selection

Mesh:

Substances:

Year:  2015        PMID: 25970703     DOI: 10.1021/acsami.5b01180

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  35 in total

1.  Graphene oxide wrapped with gold nanorods as a tag in a SERS based immunoassay for the hepatitis B surface antigen.

Authors:  Minghuan Liu; Chaohui Zheng; Malin Cui; Xiaoyan Zhang; Da-Peng Yang; Xiansong Wang; Daxiang Cui
Journal:  Mikrochim Acta       Date:  2018-09-14       Impact factor: 5.833

2.  Flow Virometry to Analyze Antigenic Spectra of Virions and Extracellular Vesicles.

Authors:  Anush Arakelyan; Wendy Fitzgerald; Sonia Zicari; Murad Vagida; Jean-Charles Grivel; Leonid Margolis
Journal:  J Vis Exp       Date:  2017-01-25       Impact factor: 1.355

Review 3.  Microfluidic methods for aptamer selection and characterization.

Authors:  Sean K Dembowski; Michael T Bowser
Journal:  Analyst       Date:  2017-12-18       Impact factor: 4.616

Review 4.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

Review 5.  Aptamer-based biosensors for virus protein detection.

Authors:  Beibei Lou; Yanfei Liu; Meilin Shi; Jun Chen; Ke Li; Yifu Tan; Liwei Chen; Yuwei Wu; Ting Wang; Xiaoqin Liu; Ting Jiang; Dongming Peng; Zhenbao Liu
Journal:  Trends Analyt Chem       Date:  2022-07-19       Impact factor: 14.908

6.  In vitro selection of DNA aptamers for the development of chemiluminescence aptasensor for neuron-specific enolase (NSE) detection.

Authors:  Yue Zheng; Yunwang Zhao; Ya Di; Lei He; Shiqi Liao; Dongdong Li; Xiaofei Liu
Journal:  RSC Adv       Date:  2019-05-17       Impact factor: 4.036

7.  A novel IgY-Aptamer hybrid system for cost-effective detection of SEB and its evaluation on food and clinical samples.

Authors:  Venkataramana Mudili; Shivakiran S Makam; Naveen Sundararaj; Chandranayaka Siddaiah; Vijai Kumar Gupta; Putcha V Lakshmana Rao
Journal:  Sci Rep       Date:  2015-10-19       Impact factor: 4.379

8.  Fluorescence based Aptasensors for the determination of hepatitis B virus e antigen.

Authors:  Rongrong Huang; Zhijiang Xi; Yan Deng; Nongyue He
Journal:  Sci Rep       Date:  2016-08-08       Impact factor: 4.379

Review 9.  Use of Aptamers as Diagnostics Tools and Antiviral Agents for Human Viruses.

Authors:  Víctor M González; M Elena Martín; Gerónimo Fernández; Ana García-Sacristán
Journal:  Pharmaceuticals (Basel)       Date:  2016-12-16

Review 10.  Recent advances in nano scaffolds for bone repair.

Authors:  Huan Yi; Fawad Ur Rehman; Chunqiu Zhao; Bin Liu; Nongyue He
Journal:  Bone Res       Date:  2016-12-13       Impact factor: 13.567

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.