Literature DB >> 25966481

Flexible Non-Constrained RF Wrist Pulse Detection Sensor Based on Array Resonators.

Yong-Jun An, Byung-Hyun Kim, Gi-Ho Yun, Sung-Woo Kim, Seung-Bum Hong, Jong-Gwan Yook.   

Abstract

This paper presents the development of a non-contact, nonintrusive wrist pulse sensor based on the near-field variation of an array resonator. A compact resonator and its array were designed and fabricated on flexible substrate. The reflection coefficient of the resonator can vary as a function of the distance between the resonator and the walls of the major arteries, and the corresponding variation is utilized to obtain heart rate information at the wrist. To detect very weak pulse signals from the main arteries, a sensitivity enhancement technique was devised using a radio frequency (RF) array resonator. The sensor system was implemented with an RF switch to combine or select appropriate signals from the resonator element and was tested using the 2.4 GHz ISM band. The results demonstrated the sensor system's excellent performance in both sequential and simultaneous detection schemes. The measurement results showed that a heartbeat pulse can be detected from both radial and ulnar arteries via the array resonators. Considering the high sensitivity and characteristics, the proposed detection system can be utilized as a wearable, long-term health monitoring device.

Mesh:

Year:  2015        PMID: 25966481     DOI: 10.1109/TBCAS.2015.2406776

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  5 in total

1.  Passive Self Resonant Skin Patch Sensor to Monitor Cardiac Intraventricular Stroke Volume Using Electromagnetic Properties of Blood.

Authors:  Fayez Alruwaili; Kim Cluff; Jacob Griffith; Hussam Farhoud
Journal:  IEEE J Transl Eng Health Med       Date:  2018-09-26       Impact factor: 3.316

2.  Developing a Wireless, High Precision and Processing Speed Pulse Monitoring Headset Using Photoplethysmography.

Authors:  Yunhui Jiang; Jian Tang; Xiaoliang Wang; Chao Shen
Journal:  IEEE J Transl Eng Health Med       Date:  2017-10-20       Impact factor: 3.316

3.  Real-time Humidity Sensor Based on Microwave Resonator Coupled with PEDOT:PSS Conducting Polymer Film.

Authors:  Jin-Kwan Park; Tae-Gyu Kang; Byung-Hyun Kim; Hee-Jo Lee; Hyang Hee Choi; Jong-Gwan Yook
Journal:  Sci Rep       Date:  2018-01-11       Impact factor: 4.379

4.  A Supersensitive, Multidimensional Flexible Strain Gauge Sensor Based on Ag/PDMS for Human Activities Monitoring.

Authors:  Hui Li; Jinjie Zhang; Jing Chen; Zebang Luo; Jinyong Zhang; Yousef Alhandarish; Qiuhua Liu; Wei Tang; Lei Wang
Journal:  Sci Rep       Date:  2020-03-13       Impact factor: 4.379

5.  Acoustic Sensing as a Novel Wearable Approach for Cardiac Monitoring at the Wrist.

Authors:  Piyush Sharma; Syed Anas Imtiaz; Esther Rodriguez-Villegas
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.