Literature DB >> 25960835

Microbial air quality and bacterial surface contamination in ambulances during patient services.

Pipat Luksamijarulkul1, Sirikun Pipitsangjan2.   

Abstract

OBJECTIVES: We sought to assess microbial air quality and bacterial surface contamination on medical instruments and the surrounding areas among 30 ambulance runs during service.
METHODS: We performed a cross-sectional study of 106 air samples collected from 30 ambulances before patient services and 212 air samples collected during patient services to assess the bacterial and fungal counts at the two time points. Additionally, 226 surface swab samples were collected from medical instrument surfaces and the surrounding areas before and after ambulance runs. Groups or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lactophenol cotton blue. Data were analyzed using descriptive statistics, t-test, and Pearson's correlation coefficient with a p-value of less than 0.050 considered significant.
RESULTS: The mean and standard deviation of bacterial and fungal counts at the start of ambulance runs were 318±485cfu/m(3) and 522±581cfu/m(3), respectively. Bacterial counts during patient services were 468±607cfu/m(3) and fungal counts were 656±612cfu/m(3). Mean bacterial and fungal counts during patient services were significantly higher than those at the start of ambulance runs, p=0.005 and p=0.030, respectively. For surface contamination, the overall bacterial counts before and after patient services were 0.8±0.7cfu/cm(2) and 1.3±1.1cfu/cm(2), respectively (p<0.001). The predominant isolated bacteria and fungi were Staphylococcus spp. and Aspergillus spp., respectively. Additionally, there was a significantly positive correlation between bacterial (r=0.3, p<0.010) and fungal counts (r=0.2, p=0.020) in air samples and bacterial counts on medical instruments and allocated areas.
CONCLUSIONS: This study revealed high microbial contamination (bacterial and fungal) in ambulance air during services and higher bacterial contamination on medical instrument surfaces and allocated areas after ambulance services compared to the start of ambulance runs. Additionally, bacterial and fungal counts in ambulance air showed a significantly positive correlation with the bacterial surface contamination on medical instruments and allocated areas. Further studies should be conducted to determine the optimal intervention to reduce microbial contamination in the ambulance environment.

Entities:  

Keywords:  Ambulances; Bacterial Counts; Microbiology Air

Year:  2015        PMID: 25960835      PMCID: PMC4412456          DOI: 10.5001/omj.2015.23

Source DB:  PubMed          Journal:  Oman Med J        ISSN: 1999-768X


  33 in total

1.  Profiles of airborne fungi in buildings and outdoor environments in the United States.

Authors:  Brian G Shelton; Kimberly H Kirkland; W Dana Flanders; George K Morris
Journal:  Appl Environ Microbiol       Date:  2002-04       Impact factor: 4.792

2.  Fungal and other spore counts as predictors of admissions for asthma in the Trent region.

Authors:  R Newson; D Strachan; J Corden; W Millington
Journal:  Occup Environ Med       Date:  2000-11       Impact factor: 4.402

Review 3.  Bioaerosol health effects and exposure assessment: progress and prospects.

Authors:  J Douwes; P Thorne; N Pearce; D Heederik
Journal:  Ann Occup Hyg       Date:  2003-04

4.  Microbial air quality in mass transport buses and work-related illness among bus drivers of Bangkok Mass Transit Authority.

Authors:  Pipat Luksamijarulkul; Viboonsri Sundhiyodhin; Soavalug Luksamijarulkul; Orawan Kaewboonchoo
Journal:  J Med Assoc Thai       Date:  2004-06

5.  The preparedness of emergency medical services against occupationally acquired communicable diseases in the prehospital environment in South Africa.

Authors:  Ozayr Mahomed; Champaklal Chaganlal Jinabhai; Myra Taylor; Arthur Yancey
Journal:  Emerg Med J       Date:  2007-07       Impact factor: 2.740

6.  Influenza vaccination among emergency medical services and emergency department personnel.

Authors:  Erik Rueckmann; Manish N Shah; Sharon G Humiston
Journal:  Prehosp Emerg Care       Date:  2009 Jan-Mar       Impact factor: 3.077

7.  Laboratory facility design and microbial indoor air quality in selected hospital laboratories.

Authors:  Pipat Luksamijarulkul; Nuchanard Kiennukul; Pisit Vatthanasomboon
Journal:  Southeast Asian J Trop Med Public Health       Date:  2014-05       Impact factor: 0.267

8.  Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC).

Authors:  Lynne Sehulster; Raymond Y W Chinn
Journal:  MMWR Recomm Rep       Date:  2003-06-06

9.  The microbiological quality of air improves when using air conditioning systems in cars.

Authors:  Ralf-Peter Vonberg; Petra Gastmeier; Björn Kenneweg; Hinrich Holdack-Janssen; Dorit Sohr; Iris F Chaberny
Journal:  BMC Infect Dis       Date:  2010-06-01       Impact factor: 3.090

Review 10.  Aerosols and splatter in dentistry: a brief review of the literature and infection control implications.

Authors:  Stephen K Harrel; John Molinari
Journal:  J Am Dent Assoc       Date:  2004-04       Impact factor: 3.634

View more
  3 in total

Review 1.  The Emergency Medical Service Microbiome.

Authors:  Andrew J Hudson; Graeme D Glaister; Hans-Joachim Wieden
Journal:  Appl Environ Microbiol       Date:  2018-02-14       Impact factor: 4.792

2.  Positive and Negative Ions Potently Inhibit the Viability of Airborne Gram-Positive and Gram-Negative Bacteria.

Authors:  Giuliana Banche; Anna Maria Cuffini; Sara Comini; Narcisa Mandras; Maria Rita Iannantuoni; Francesca Menotti; Andrea Giuseppe Musumeci; Giorgia Piersigilli; Valeria Allizond
Journal:  Microbiol Spectr       Date:  2021-11-10

3.  Prehospital infection control and prevention in Denmark: a cross-sectional study on guideline adherence and microbial contamination of surfaces.

Authors:  Heidi Storm Vikke; Matthias Giebner; Hans Jørn Kolmos
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2018-09-05       Impact factor: 2.953

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.