Literature DB >> 25960058

Bioabsorbable Versus Metallic Screw Fixation for Tibiofibular Syndesmotic Ruptures: A Meta-Analysis.

Dorien M van der Eng1, Niels W L Schep2, Tim Schepers2.   

Abstract

Ankle fractures with syndesmotic rupture require operative treatment. In most cases, this consists of fixation of the tibiofibular joint with 1 or more screws. Bioabsorbable screws are used for the same purpose but have the advantage that screw removal is unnecessary. The aim of the present study was to compare the results of bioabsorbable and metallic syndesmotic screws. A systematic search was performed in the Ovid MEDLINE electronic database and Google Scholar. Three randomized controlled trials and one comparison study, with 260 patients, were included. The experimental group consisted of patients with syndesmotic injuries treated with bioabsorbable screws versus the control group (patients treated with metallic screws). The primary outcomes were complications and wound infections. No statistically significant difference was demonstrable in the overall number of complications between the 2 groups. In the group of patients with a bioabsorbable screw, 32 of 137 (23.4%) experienced a complication versus 7 of 123 patients (5.7%) with a metallic screw. Data on wound-related complications showed no statistically significant difference, 19.7% versus 5.7%. The average maximum range of motion in both groups was comparable. Bioabsorbable syndesmotic screws and metallic syndesmotic screws were comparable with respect to the incidence of complications and range of motion. However, the absolute number of complications was greater with bioabsorbable screws.
Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ankle fracture; bioabsorbable screw; syndesmosis; syndesmotic rupture

Mesh:

Substances:

Year:  2015        PMID: 25960058     DOI: 10.1053/j.jfas.2015.03.014

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  5 in total

Review 1.  Management of syndesmotic injuries: What is the evidence?

Authors:  Marc Schnetzke; Sven Y Vetter; Nils Beisemann; Benedict Swartman; Paul A Grützner; Jochen Franke
Journal:  World J Orthop       Date:  2016-11-18

2.  Reduced incidence and economic cost of hardware removal after ankle fracture surgery: a 20-year nationwide registry study.

Authors:  Nikke Partio; Tuomas T Huttunen; Heikki M Mäenpää; Ville M Mattila
Journal:  Acta Orthop       Date:  2020-02-28       Impact factor: 3.717

Review 3.  A systematic review of ankle fracture-dislocations: Recent update and future prospects.

Authors:  Mu-Min Cao; Yuan-Wei Zhang; Sheng-Ye Hu; Yun-Feng Rui
Journal:  Front Surg       Date:  2022-08-09

4.  Is it necessary to remove syndesmotic screw before weight-bearing ambulation?

Authors:  Young Jae Moon; Dong Hee Kim; Kwang-Bok Lee
Journal:  Medicine (Baltimore)       Date:  2020-03       Impact factor: 1.817

5.  Αbsorbable Plates for Isolated Ulnar Diaphyseal Fractures in Adults - A Case Series Study.

Authors:  Dimitrios Kapoutsis; Dimitrios Kitridis; Nikolaos Platon Sachinis; Avraam Ploumis; Panagiotis Givissis
Journal:  J Orthop Case Rep       Date:  2020-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.