Literature DB >> 25955395

First Clinical Evaluation of High-Pitch Dual-Source Computed Tomographic Angiography Comparing Automated Tube Potential Selection With Automated Tube Current Modulation.

Martin Beeres1, Kimberly Williams, Ralf W Bauer, Jan Scholtz, Moritz Kaup, Tatjana Gruber-Rouh, Clara Lee, Julian L Wichmann, Claudia Frellesen, Nour-Eldin A Nour-Eldin, Thomas J Vogl, Josef Matthias Kerl, Boris Bodelle.   

Abstract

OBJECTIVE: To investigate and compare the use of automated tube potential selection (ATPS) with automated tube current modulation (ATCM) in high-pitch dual-source computed tomographic angiography (CTA) for imaging the whole aorta without electrocardiogram synchronization.
METHODS: Two groups of 60 patients underwent CTA on a dual-source computed tomographic device in high-pitch mode: ATCM (with 100-kV fixed tube potential) was used in group 1 and ATPS (with the same image quality options) in group 2. For the evaluation of radiation exposure, CT dose index and dose-length product were analyzed. Contrast and image quality were assessed by 2 independent observers.
RESULTS: The ATPS group received a higher radiation dose than the ATCM group (P < 0.001) because in 80% of patients, the software switched to use of a 120-kV tube potential. In all cases, images of the aorta were of sufficient quality.
CONCLUSIONS: High-pitch dual-source CTA of the aorta using ATPS is feasible in clinical routine, but is associated with higher radiation exposure than the ATCM protocol. This finding contradicts previously evaluations of ATPS based on single-source techniques.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25955395     DOI: 10.1097/RCT.0000000000000247

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  3 in total

1.  Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality.

Authors:  Rahul D Renapurkar; Andrew Primak; Joseph Azok; Jason Lempel; Yasmeen Tandon; Jennifer Bullen; Frank Dong; Wadih Karim; Ruffin Graham
Journal:  Eur Radiol       Date:  2017-01-13       Impact factor: 5.315

2.  Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience.

Authors:  Lei Zhao; Aishi Liu; Youmin Guo
Journal:  Jpn J Radiol       Date:  2017-10-19       Impact factor: 2.374

3.  Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-10-18       Impact factor: 3.500

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.