Literature DB >> 25954694

The influence of implant abutment surface roughness and the type of cement on retention of implant supported crowns.

S Varalakshmi Reddy1, M Sushender Reddy2, C Rajaneesh Reddy3, Padmaja Pithani4, Santosh Kumar R5, Ganesh Kulkarni6.   

Abstract

OBJECTIVES: To provide relative data on the retentive characters of the commonly used cements on different implant abutment surfaces.
MATERIALS AND METHODS: A total of 20 implant abutments were divided into 2 groups. Ten implants were unaltered and ten were air borne particle abraded with 50μ aluminium oxide. Three luting agents (Tempbond, IRM and ImProv) were used to secure the crowns to abutments. All the crowns were removed from the abutment with an Instron machine at 0.5mm per minute and tensile bond strengths were recorded. Statistical analysis was performed using Anova, Paired t-test and Post-Hoc tests.
RESULTS: IRM showed the highest mean tensile strength among the three cements when used with treated and untreated implant abutment surfaces. Change in the abutment surface roughness had no effect on the mean tensile bond strength of TempBond and IRM cements, whereas ImProv cement showed reduced tensile strength with sandblasted surface.
CONCLUSION: When increased retention is required IRM cement with either sandblasted or milled surface could be used and when retrievability is required cements of choice could be either TempBond or ImProv.

Entities:  

Keywords:  Aluminum oxide; Dental Cements; Eugenol; Methymethacrylates; Tensile strength

Year:  2015        PMID: 25954694      PMCID: PMC4413144          DOI: 10.7860/JCDR/2015/12060.5621

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  24 in total

1.  Fit of titanium and a base metal alloy metal-ceramic crown.

Authors:  S Oruç; Y Tulunoglu
Journal:  J Prosthet Dent       Date:  2000-03       Impact factor: 3.426

2.  Retentive and compressive strengths of modified zinc oxide-eugenol cements.

Authors:  S Y Lee; C C Wang; D C Chen; Y L Lai
Journal:  J Dent       Date:  2000-01       Impact factor: 4.379

3.  Mechanical properties of dental luting cements.

Authors:  Z C Li; S N White
Journal:  J Prosthet Dent       Date:  1999-05       Impact factor: 3.426

4.  Dimensional accuracy and retentive strength of a retrievable cement-retained implant-supported prosthesis.

Authors:  A P Randi; A T Hsu; A Verga; J J Kim
Journal:  Int J Oral Maxillofac Implants       Date:  2001 Jul-Aug       Impact factor: 2.804

5.  Comparative evaluation of casting retention using the ITI solid abutment with six cements.

Authors:  Ahmed Mansour; Carlo Ercoli; Gerald Graser; Ross Tallents; Mark Moss
Journal:  Clin Oral Implants Res       Date:  2002-08       Impact factor: 5.977

6.  Retentive strength, disintegration, and marginal quality of luting cements.

Authors:  S Gorodovsky; O Zidan
Journal:  J Prosthet Dent       Date:  1992-08       Impact factor: 3.426

Review 7.  Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions--a systematic review.

Authors:  Julia-Gabriela Wittneben; Christopher Millen; Urs Brägger
Journal:  Int J Oral Maxillofac Implants       Date:  2014       Impact factor: 2.804

8.  Retentive strength of metal copings on prefabricated abutments with five different cements.

Authors:  Hideki Maeyama; Takashi Sawase; Ryo Jimbo; Koji Kamada; Naoki Suketa; Junichi Fukui; Mitsuru Atsuta
Journal:  Clin Implant Dent Relat Res       Date:  2005       Impact factor: 3.932

9.  Retention forces and seating discrepancies of implant-retained castings after cementation.

Authors:  Mona Wolfart; Stefan Wolfart; Matthias Kern
Journal:  Int J Oral Maxillofac Implants       Date:  2006 Jul-Aug       Impact factor: 2.804

10.  Effect of surface roughness and cement space on crown retention.

Authors:  N Juntavee; P L Millstein
Journal:  J Prosthet Dent       Date:  1992-09       Impact factor: 3.426

View more
  1 in total

1.  An In Vitro Trial to Estimate the Retention Ability of Luting Agents Utilized with Dental Implant-Supported Prosthesis.

Authors:  Aasia Ahsan; B Khushboo; Ashish Kumar; Sweta Kumari; Bharathi Poojary; Arti Dixit; Amit Kumar; Bhumika Kamal Badiyani
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.