Literature DB >> 10709040

Fit of titanium and a base metal alloy metal-ceramic crown.

S Oruç1, Y Tulunoglu.   

Abstract

STATEMENT OF PROBLEM: Titanium has been widely used in dental implantology. However, problems remain for use of titanium in prosthodontics.
PURPOSE: This study evaluated the marginal and inner fit of metal-ceramic restorations and frameworks made with a nickel-chromium alloy (Remanium CS) and a commercially pure titanium (Rematitan). Fit was compared with SEM before and after firing of ceramic materials.
MATERIAL AND METHODS: Sixteen metal frameworks were cast with each casting material, 8 frameworks were used directly to evaluate measurements for fit (RCS: Remanium CS frameworks and TI: Rematitan frameworks). Porcelain was applied on the other 8 frameworks (RCSP: Remanium CS-porcelain and TIP: Rematitan-porcelain), fired, and then the fit was measured. Measurements were recorded at 3 points for marginal fit evaluation and at 3 points for inner fit.
RESULTS: Significant differences were recorded among the occlusal (JK) values of groups tested (P <.05). Marginal fit and inner fit of Remanium CS frameworks were better than Rematitan frameworks. However, there were no substantial differences detected among groups after firing the ceramic superstructures.
CONCLUSION: The fit of the base metal alloy metal-ceramic crowns was better than the commercially pure titanium metal-ceramic crowns. However, both artificial crowns were clinically acceptable.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10709040     DOI: 10.1016/s0022-3913(00)70134-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  The influence of implant abutment surface roughness and the type of cement on retention of implant supported crowns.

Authors:  S Varalakshmi Reddy; M Sushender Reddy; C Rajaneesh Reddy; Padmaja Pithani; Santosh Kumar R; Ganesh Kulkarni
Journal:  J Clin Diagn Res       Date:  2015-03-01

2.  In-vitro investigation to evaluate the flexural bond strengths of three commercially available ultra low fusing ceramic systems to Grade II Titanium.

Authors:  Vijay Mabrurkar; Nitin Habbu; Sayed Wahhiuddin Hashmi; Smita Musani; Nikhil Joshi
Journal:  J Int Oral Health       Date:  2013-10-26

3.  Screening on binary Ti alloy with excellent mechanical property and castability for dental prosthesis application.

Authors:  H F Li; K J Qiu; W Yuan; F Y Zhou; B L Wang; L Li; Y F Zheng; Y H Liu
Journal:  Sci Rep       Date:  2016-11-22       Impact factor: 4.379

4.  Comparative evaluation of marginal fit and axial wall adaptability of copings fabricated by metal laser sintering and lost-wax technique: An in vitro study.

Authors:  Bhushan Satish Gaikwad; Girish Nazirkar; Rajani Dable; Shailendra Singh
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

5.  An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks.

Authors:  Jae-Kwan Jung
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

6.  Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

Authors:  Min-Kyung Ji; Ji-Hee Park; Sang-Won Park; Kwi-Dug Yun; Gye-Jeong Oh; Hyun-Pil Lim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

7.  Internal adaptation of cast titanium crowns.

Authors:  Sicknan Soares da Rocha; Gelson Luis Adabo; Ricardo Faria Ribeiro; Renata Garcia Fonseca
Journal:  J Appl Oral Sci       Date:  2007-08       Impact factor: 2.698

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.