Literature DB >> 25954660

Safe, Effective and Easily Reproducible Fusion Technique for CV Junction Instability.

Madhukar T Nayak1, Raghavendra Bakki Sannegowda2.   

Abstract

INTRODUCTION: The Craniovertebral junction (CVJ) refers to a bony enclosure where the occipital bone surrounds the foramen magnum, the atlas and the axis vertebrae. Because of the complexity of structures, CVJ instability is associated with diagnostic and therapeutic problems. Posterior CV fusion procedures have evolved a lot over the last couple of decades. There has been a lookout for one such surgical procedure which is inherently safe, simple, easily reproducible and biomechanically sound. In our study, we present the initial experience the cases of CV junction instrumentation using O-C1-C2 screw & rod construct operated by the author. AIMS AND
OBJECTIVES: The current study is a descriptive analysis of the cases of CVJ instability treated by us with instrumentation using O-C1-C2 screw and rod construct fusion technique.
MATERIALS AND METHODS: It is a retrospective, analytical study in which cases of CV junction instability operated by the author between January 2010 to March 2014 were analysed using various clinical, radiological and outcome parameters.
CONCLUSION: CV junction instrumentation using O-C1-C2 screw and rod construct fusion technique proved to be safe, effective, easily reproducible and biomechanically sound technique which can be adopted by all surgeons who may be at any stage of their learning curve.

Entities:  

Keywords:  Atlanto axial dislocation; Basilar invagination; CV junction anomalies; CVJ instrumentation; Cervical canal stenosis; Lateral mass screws; Pedicle screws

Year:  2015        PMID: 25954660      PMCID: PMC4413109          DOI: 10.7860/JCDR/2015/11306.5731

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  13 in total

1.  Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques.

Authors:  I Oda; K Abumi; L C Sell; C J Haggerty; B W Cunningham; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1999-11-15       Impact factor: 3.468

2.  Atlantoaxial transarticular screw fixation for a high-riding vertebral artery.

Authors:  Masashi Neo; Mutsumi Matsushita; Yasushi Iwashita; Tadashi Yasuda; Takeshi Sakamoto; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2003-04-01       Impact factor: 3.468

3.  Feasibility of intralaminar, lateral mass, or pedicle axis vertebra screws in children under 10 years of age: a tomographic study.

Authors:  Alexandre Fogaça Cristante; Alessandro Gonzalez Torelli; Rafael Bellucci Kohlmann; Ivan Dias da Rocha; Olavo Letaif Biraghi; Alexandre Sadao Iutaka; Raphael Martus Marcon; Reginaldo Perilo Oliveira; Tarcísio Eloy Pessoa de Barros Filho
Journal:  Neurosurgery       Date:  2012-04       Impact factor: 4.654

4.  Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation.

Authors:  Hiroshi Kuroki; Setti S Rengachary; Vijay K Goel; Scott A Holekamp; Ville Pitkänen; Nabil A Ebraheim
Journal:  Neurosurgery       Date:  2005-01       Impact factor: 4.654

5.  Biomechanical stability of a posterior-alone fixation technique after craniovertebral junction realignment.

Authors:  Roy Thomas Daniel; Aditya Muzumdar; Aditya Ingalhalikar; Mark Moldavsky; Saif Khalil
Journal:  World Neurosurg       Date:  2011-11-07       Impact factor: 2.104

6.  Craniometric measurements in the assessment of craniovertebral settling: are they still relevant in the age of cross-sectional imaging?

Authors:  Yune Kwong; Nitin Rao; Khalid Latief
Journal:  AJR Am J Roentgenol       Date:  2011-04       Impact factor: 3.959

7.  Posterior C1-C2 fusion with polyaxial screw and rod fixation.

Authors:  J Harms; R P Melcher
Journal:  Spine (Phila Pa 1976)       Date:  2001-11-15       Impact factor: 3.468

Review 8.  Fusions at the craniovertebral junction.

Authors:  Raheel Ahmed; Vincent C Traynelis; Arnold H Menezes
Journal:  Childs Nerv Syst       Date:  2008-04-04       Impact factor: 1.475

9.  Comparison of fatigue strength of C2 pedicle screws, C2 pars screws, and a hybrid construct in C1-C2 fixation.

Authors:  Brian W Su; Adam L Shimer; Suresh Chinthakunta; Kanaan Salloum; Christopher P Ames; Alexander R Vaccaro; Brandon Bucklen
Journal:  Spine (Phila Pa 1976)       Date:  2014-01-01       Impact factor: 3.468

Review 10.  Embryology and bony malformations of the craniovertebral junction.

Authors:  Dachling Pang; Dominic N P Thompson
Journal:  Childs Nerv Syst       Date:  2010-12-31       Impact factor: 1.475

View more
  1 in total

1.  Posterior occipito cervical decompression with fixation and fusion in Cranio vertebral junction compression.

Authors:  Lal Rehman; Iram Bokhari; Ali Afzal; Shakeel Ahmad
Journal:  Pak J Med Sci       Date:  2017 Sep-Oct       Impact factor: 1.088

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.