Literature DB >> 21937932

Feasibility of intralaminar, lateral mass, or pedicle axis vertebra screws in children under 10 years of age: a tomographic study.

Alexandre Fogaça Cristante1, Alessandro Gonzalez Torelli, Rafael Bellucci Kohlmann, Ivan Dias da Rocha, Olavo Letaif Biraghi, Alexandre Sadao Iutaka, Raphael Martus Marcon, Reginaldo Perilo Oliveira, Tarcísio Eloy Pessoa de Barros Filho.   

Abstract

BACKGROUND: There are several techniques for screw insertion in upper cervical spine surgery, and the use of the 3.5-mm screw is usually the standard. However, there is no consensus regarding the feasibility of using these screws in the pediatric population.
OBJECTIVE: To determine the measurement of the lamina angle, lamina and pedicle length and thickness, and lateral mass length of the topographic axial view of the axis vertebra of 2- to 10-year-old children to guide the use of surgical screws.
METHODS: Seventy-five computed tomography scans from 24- to 120-month-old patients were studied. Measurements were taken in an axial view of C2 and correlated with 2 age groups and both sexes. Statistical analysis was performed with the Student t test.
RESULTS: In the 24- to 48-month age group, only 5.5% of the lamina and 8.3% of the pedicles had thicknesses < 3.5 mm. In the 49- to 120-month age group, there were no lamina thickness values < 3.5 mm, and 1.2% of pedicle thicknesses were < 3.5 mm. Both age groups had no lamina and pedicle lengths < 12 mm and no lateral mass lengths > 12 mm.
CONCLUSION: In the majority of cases, the use of 3.5-mm lamina and pedicle screws in children is feasible. A base value of 45° for the spinolaminar angle can be adopted as a reference for insertion of screws in the C2 lamina. This information can be particularly useful for decision making during preoperative planning for C1-C2 or craniocervical arthrodesis in children.

Entities:  

Mesh:

Year:  2012        PMID: 21937932     DOI: 10.1227/NEU.0b013e3182367417

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  12 in total

1.  Tomographic correlation for Magerl's technique in C1-C2 arthrodesis in children.

Authors:  Bárbara Camargo Chiaramonti; So Yeon Kim; Luiz Roberto Delboni Marchese; Olavo Biraghi Letaif; Raphael Martus Marcon; Alexandre Fogaça Cristante
Journal:  Acta Ortop Bras       Date:  2013       Impact factor: 0.513

2.  Tomographic correlation of the Magerl technique for C1-C2 arthrodesis in rheumatoid arthritis.

Authors:  Luiz Roberto Delboni Marchese; Marcelo Batista Bonadio; Olavo Biraghi Letaif; Alexandre Fogaça Cristante; Reginaldo Perilo Oliveira; Tarcísio Eloy Pessoa de Barros
Journal:  Acta Ortop Bras       Date:  2013-07       Impact factor: 0.513

3.  Safe, Effective and Easily Reproducible Fusion Technique for CV Junction Instability.

Authors:  Madhukar T Nayak; Raghavendra Bakki Sannegowda
Journal:  J Clin Diagn Res       Date:  2015-03-01

4.  Anatomic feasibility of posterior cervical pedicle screw placement in children: computerized tomographic analysis of children under 10 years old.

Authors:  HoJin Lee; Jae Taek Hong; Il Sup Kim; Moon Suk Kim; Jae Hoon Sung; Sang Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2014-12-31

5.  Computed tomography morphometric analysis of C2 translaminar screw fixation of Wright's technique and a modified technique in the pediatric cervical spine.

Authors:  Dong-Dong Xia; Sheng-Lei Lin; Wei Chen; Zhong-Hai Shen; Yao Li; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Eur Spine J       Date:  2013-12-12       Impact factor: 3.134

Review 6.  Anatomical considerations of C2 lamina for the placement of translaminar screw: a review of the literature.

Authors:  D Chytas; D S Korres; G C Babis; N E Efstathopoulos; E C Papadopoulos; K Markatos; V S Nikolaou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08

7.  Suitability of 3.5-mm screw for the atlas in children: a retrospective computed tomography analysis.

Authors:  Jiarui Chen; Tuo Liang; Yajie Hu; Youliang Ma; Shengsheng Huang; Liyi Chen; Jie Jiang; Hao Li; Tianyou Chen; Jiemei Cen; Chong Liu; Xinli Zhan
Journal:  Eur Spine J       Date:  2022-02-28       Impact factor: 2.721

8.  [Biomechanical stability evaluation of the fixation technique for crossed rods consisting of occipital plate and C 2 bilateral lamina screws].

Authors:  Feng Qiu; Xilin Xu; Xiangyang Ma; Weicheng Jiang; Gengchao Liu; Zhouqun Fang; Zejiang Lin
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-12-15

Review 9.  Therapeutic approaches for spinal cord injury.

Authors:  Alexandre Fogaça Cristante; Tarcísio Eloy Pessoa de Barros Filho; Raphael Martus Marcon; Olavo Biraghi Letaif; Ivan Dias da Rocha
Journal:  Clinics (Sao Paulo)       Date:  2012-10       Impact factor: 2.365

Review 10.  Fractures of the cervical spine.

Authors:  Raphael Martus Marcon; Alexandre Fogaça Cristante; William Jacobsen Teixeira; Douglas Kenji Narasaki; Reginaldo Perilo Oliveira; Tarcísio Eloy Pessoa de Barros Filho
Journal:  Clinics (Sao Paulo)       Date:  2013-11       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.