Literature DB >> 25953479

Use of Quilting Sutures During Abdominoplasty to Prevent Seroma Formation: Are They Really Effective?

Marcos Sforza1, Rodwan Husein1, Katarina Andjelkov1, Paulo Cesar Rozental-Fernandes1, Renato Zaccheddu1, Milan Jovanovic1.   

Abstract

BACKGROUND: Abdominoplasty surgery is one of the most popular cosmetic procedures performed in plastic surgery. As with any surgical procedure, it is associated with risks and complications, primarily that of seroma formation. Quilting sutures are a recent development in abdominoplasty surgery that aim to prevent the incidence of seroma.
OBJECTIVES: The aim of this article was to assess the effectiveness of quilting suturing in the prevention of seroma formation.
METHODS: In our retrospective clinical study, 414 female patients underwent abdominoplasty surgery with liposculpture contouring. The patients were divided in to three groups. The first group, comprising of 100 patients, were fitted with two drains postoperatively and no quilting sutures. The second group of 226 patients underwent quilting suturing in addition to receiving two drains. And the final group of 88 patients also underwent quilting suturing, but received only one drain. Post-operative seroma diagnosis was confirmed with the presence of clinical signs and symptoms.
RESULTS: The data was analysed using Fisher's exact test. With P < .000, we rejected our null hypothesis that there is no difference in results between the procedure with sutures and that without sutures. We calculated that the probability of having seroma with sutures to be <0.02. In contrast, abstinence from quilting sutures resulted in a 12% risk of seroma formation.
CONCLUSIONS: The use of quilting sutures is a significantly effective measure for the prevention of seroma formation. LEVEL OF EVIDENCE: 4 Therapeutic.
© 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 25953479     DOI: 10.1093/asj/sju103

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


  7 in total

1.  The use of adjuncts to reduce seroma in open incisional hernia repair: a systematic review.

Authors:  L H Massey; S Pathak; A Bhargava; N J Smart; I R Daniels
Journal:  Hernia       Date:  2017-10-25       Impact factor: 4.739

Review 2.  The Global Prevalence of Seroma After Abdominoplasty: A Systematic Review and Meta-Analysis.

Authors:  Nader Salari; Behnaz Fatahi; Yalda Bartina; Mohsen Kazeminia; Mohammadbagher Heydari; Masoud Mohammadi; Mahvan Hemmati; Shamarina Shohaimi
Journal:  Aesthetic Plast Surg       Date:  2021-06-02       Impact factor: 2.708

3.  Comparing Seroma Formation at the Deep Inferior Epigastric Perforator, Transverse Musculocutaneous Gracilis, and Superior Gluteal Artery Perforator Flap Donor Sites after Microsurgical Breast Reconstruction.

Authors:  Alisha Merchant; Nicole E Speck; Michal Michalak; Dirk J Schaefer; Jian Farhadi
Journal:  Arch Plast Surg       Date:  2022-07-30

4.  Adverse Events of Soft Tissue Coagulation Using a Helium-Based Plasma Technology Alone and in Combination With Ultrasound-Assisted Liposuction.

Authors:  Paul G Ruff; Paul Vanek; Matthew Nykiel
Journal:  Aesthet Surg J Open Forum       Date:  2022-07-18

5.  Percutaneous Quilting Technique for the Treatment of Morel-Lavallée Lesion.

Authors:  Gautam Kumar; Alagu Pandiyan; Bipin Theruvil
Journal:  Indian J Orthop       Date:  2020-04-05       Impact factor: 1.251

6.  Response to "Seroma Prevention in Abdominoplasty: Eliminating the Cause".

Authors:  Marcos Sforza; Katarina Andjelkov; Rodwan Husein; Renato Zaccheddu; Connor Atkinson
Journal:  Aesthet Surg J       Date:  2015-10-23       Impact factor: 4.283

Review 7.  Standards and Trends in Lipoabdominoplasty.

Authors:  Neil O'Kelly; Khang Nguyen; Alexander Gibstein; James P Bradley; Neil Tanna; Alan Matarasso
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-10-26
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.