Literature DB >> 25952913

Aseptic loosening of cobalt chromium monoblock sockets after hip resurfacing.

Harlan C Amstutz1, Michel J Le Duff1.   

Abstract

INTRODUCTION: Acetabular component loosening is a leading cause for revision after metal-on-metal hip resurfacing arthroplasty (MMHRA). We aimed to identify potential risk factors and determine radiographic signs associated with this mode of failure.
METHODS: From a series of 1375 hips treated with MMHRA, 21 (20 patients) underwent revision surgery secondary to aseptic loosening of the acetabular component and 6 patients had a radiographically loose acetabular component. A control group of 27 hips (26 patients) was selected among the patients that did not have a revision, and was matched for age, gender, component size and diagnosis.
RESULTS: Mean time to revision in the loosening group was 103.0 months and the mean time of follow-up in the control group was 161.4 months. We found greater activity levels, range of motion scores, and cup abduction angles in the loosening group. The centre-edge (CE) angle of Wiberg was 10° lower in the loosening group compared with the control group. In addition, 11 of the hips from the study group presented a sclerotic halo superior to the cup on the last radiograph vs. none in the control group. There was no difference in the prevalence of postoperative reaming gaps or radiographic signs of neck-cup impingement between the 2 groups. DISCUSSION: Risk factors for acetabular loosening included hip dysplasia with low CE angle, and a large cup abduction angle. The patient's level of activity influences the appearance of symptoms and the time to revision. We recommend selecting patients with a sufficient CE angle and properly orienting the cup.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25952913     DOI: 10.5301/hipint.5000251

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

1.  Current indications for hip resurfacing arthroplasty in 2016.

Authors:  Robert Sershon; Rishi Balkissoon; Craig J Della Valle
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Biomimetic Multispiked Connecting Ti-Alloy Scaffold Prototype for Entirely-Cementless Resurfacing Arthroplasty Endoprostheses-Exemplary Results of Implantation of the Ca-P Surface-Modified Scaffold Prototypes in Animal Model and Osteoblast Culture Evaluation.

Authors:  Ryszard Uklejewski; Piotr Rogala; Mariusz Winiecki; Renata Tokłowicz; Piotr Ruszkowski; Maria Wołuń-Cholewa
Journal:  Materials (Basel)       Date:  2016-06-29       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.