Literature DB >> 25946392

MRI-guided percutaneous transpedicular biopsy of thoracic and lumbar spine using a 0.23t scanner with optical instrument tracking.

Ming Liu1, Roberto Blanco Sequeiros2, Yujun Xu1, Xiangmeng He1, Tongyin Zhu3, Lei Li4, Yubo Lü1, Jie Huang1, Chengli Li1.   

Abstract

PURPOSE: To prospectively evaluate the safety and accuracy of magnetic resonance imaging (MRI)-guided percutaneous transpedicular biopsy of thoracic and lumbar spine using 0.23T magnetic resonance imaging with optical tracking.
MATERIALS AND METHODS: Sixty-seven thoracic and lumbar spine lesions in 67 patients underwent MRI-guided percutaneous transpedicular biopsy using 0.23T MRI with optical tracking. These lesions were divided into two groups according to the location: 16 lesions in the thoracic spine and 51 lesions in the lumbar spine. The diagnostic accuracy, sensitivity, and specificity were calculated, and comparison of the two groups was performed using Fisher's exact test. Each patient was monitored for complications.
RESULTS: All specimens obtained were sufficient for diagnosis. Histological examination of MRI-guided percutaneous biopsy revealed 38 malignant and 29 benign lesions. The final diagnoses from surgery or clinical follow-up were 42 malignant lesions and 25 benign lesions. The combined diagnostic performance of MRI-guided percutaneous transpedicular thoracic and lumbar biopsy in diagnosing malignant tumors was as follows: accuracy, 94%; sensitivity, 89%; and specificity, 100%. There was no significant difference between the two groups (P = 1, Fisher's exact test). No serious complications occurred.
CONCLUSION: MRI-guided percutaneous transpedicular biopsy is a safe and accurate diagnostic technique to evaluate thoracic and lumbar spine lesions.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  biopsy; guidance; interventional radiology; magnetic resonance; spine

Mesh:

Year:  2015        PMID: 25946392     DOI: 10.1002/jmri.24924

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

Review 2.  Review article: the current status of CT-guided needle biopsy of the spine.

Authors:  Asif Saifuddin; Valentina Palloni; Hannah du Preez; Syed Ehtasham Junaid
Journal:  Skeletal Radiol       Date:  2020-08-19       Impact factor: 2.199

3.  Magnetic Resonance Imaging-Guided Transplantation of Neural Stem Cells into the Porcine Spinal Cord.

Authors:  Jason J Lamanna; Lindsey N Urquia; Carl V Hurtig; Juanmarco Gutierrez; Cody Anderson; Pete Piferi; Thais Federici; John N Oshinski; Nicholas M Boulis
Journal:  Stereotact Funct Neurosurg       Date:  2017-01-28       Impact factor: 1.875

4.  Minimal artifact actively shimmed metallic needles in MRI.

Authors:  Saikat Sengupta; Xinqiang Yan; Tamarya L Hoyt; Gary Drake; Anthony Gunderman; Yue Chen
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

5.  Predictive value of pedicle involvement with MRI in spine metastases.

Authors:  Wang Mi Liu; Rong Xing; Chong Bian; Yun Liang; Libo Jiang; Chen Qian; Jian Dong
Journal:  Oncotarget       Date:  2016-09-20

6.  Transnasal Endoscopic and Transoral Approaches in the Biopsies of Ventral Atlas and Axis Vertebrae: A Comprehensive Retrospective Study for Preprocedural Scheme, Biopsy Procedure, Core Technique Analysis, Diagnostic Yield and Clinical Outcome.

Authors:  Xianhao Shao; Jianmin Li; Qiang Yang; Ka Li; Yuan Yao; Feifei Sun; Zhenfeng Li
Journal:  Orthop Surg       Date:  2022-06-15       Impact factor: 2.279

Review 7.  Holistic Approach to the Diagnosis and Treatment of Patients with Tumor Metastases to the Spine.

Authors:  Hanna Nowak; Dominika Maria Szwacka; Monika Pater; Wojciech Krzysztof Mrugalski; Michał Grzegorz Milczarek; Magdalena Staniszewska; Roman Jankowski; Anna-Maria Barciszewska
Journal:  Cancers (Basel)       Date:  2022-07-18       Impact factor: 6.575

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.