Prediction of refractive outcomes with toric intraocular lens implantation.

Adi Abulafia1, Graham D Barrett2, Guy Kleinmann2, Shay Ofir2, Adi Levy2, Arie L Marcovich2, Adi Michaeli2, Douglas D Koch2, Li Wang2, Ehud I Assia2.   

Abstract

PURPOSE: To evaluate and compare the accuracy of different methods to measure and predict postoperative astigmatism with toric intraocular lens (IOL) implantation.
SETTING: Ein-Tal Ophthalmology Center, Tel-Aviv, Israel.
DESIGN: Retrospective case series.
METHODS: Postoperative corneal astigmatism was measured with 3 devices (IOLMaster 500; optical low-coherence reflectometry [OLCR]-based Lenstar LS 900; Atlas topographer) and compared with the manifest astigmatic refractive outcome in patients with toric IOLs. The error in the predicted residual astigmatism was calculated by vector analysis according to the measurement and calculation method used to predict the required toric IOL cylinder power.
RESULTS: The centroid errors in predicted residual astigmatism were against the rule with the Alcon and Holladay toric calculators (0.53 to 0.56 diopter [D]), were lower with the Baylor nomogram (0.21 to 0.26 D), and were lowest for the Barrett toric calculator (0.01 to 0.16 D) (P <.001). The Barrett toric calculator had the lowest median absolute error in predicted residual astigmatism (0.35 to 0.54 D, all devices) compared with the Alcon and Holladay toric calculators with or without the Baylor nomogram (P <.021). The Barrett toric calculator and the OLCR device achieved the most accurate results; 75.0% and 97.1% of eyes were within ±0.50 D and ±0.75 D of the predicted residual astigmatism, respectively.
CONCLUSION: Prediction of astigmatic outcomes with toric IOLs can be improved with appropriate measuring devices and methods to establish the required toric IOL power.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25936681     DOI: 10.1016/j.jcrs.2014.08.036

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  21 in total

1.  Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods.

Authors:  Jun Yang; Hong Zhang; Xiao-Tong Yang; Fang Tian; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

2.  Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens.

Authors:  Antoine Levron; Hussam El Chehab; Emilie Agard; Roman Chudzinski; Jeremy Billant; Corinne Dot
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-15       Impact factor: 3.117

3.  Accuracy of two devices and three different calculation methods for predicting residual astigmatism after intraocular lens implantation.

Authors:  Kendall Bicknell; Christopher Helpert; Kourtney Dwyer; Brett McKnight; Sonali Singh; Samuel Fulcher; Derrick Fung
Journal:  Proc (Bayl Univ Med Cent)       Date:  2020-03-03

4.  Refractive Outcomes for Cataract Surgery With Toric Intraocular Lenses at a Veterans Affairs Medical Center.

Authors:  Elaine M Tran; Kevin S Tang; Allison J Chen; Michael L Chen; David R Rivera; Jorge J Rivera; Paul B Greenberg
Journal:  Fed Pract       Date:  2020-03

5.  Corneal surgically induced astigmatism in resident surgeons.

Authors:  Timothy Sipos; Kendall Bicknell
Journal:  Proc (Bayl Univ Med Cent)       Date:  2021-10-04

6.  Comparison of Barrett Toric Calculations Using Measured and Predicted Posterior Corneal Astigmatism in Cataract Surgery Patients.

Authors:  Mark K Lukewich; Fahmeeda Murtaza; Sohel Somani; Eric S Tam; Hannah H Chiu
Journal:  Clin Ophthalmol       Date:  2022-06-01

7.  Comparison of the clinical outcomes of Eyecryl and Tecnis® toric intraocular lenses: A real-world study.

Authors:  Mithun Thulasidas; Ajita Sasidharan; Balam Pradeep
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 2.969

8.  Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2016-11-03

9.  Comparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation.

Authors:  Dae-Young Park; Dong Hui Lim; Sungsoon Hwang; Joo Hyun; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2017-08-24       Impact factor: 2.209

10.  Comparison of Two Toric IOL Calculation Methods.

Authors:  C Kern; K Kortüm; M Müller; A Kampik; S Priglinger; W J Mayer
Journal:  J Ophthalmol       Date:  2018-01-10       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.