Literature DB >> 25935027

Quantitative evaluation of knee subchondral bone mineral density using cone beam computed tomography.

Mikael J Turunen, Juha Töyräs, Harri T Kokkonen, Jukka S Jurvelin.   

Abstract

Contrast agent enhanced cone beam computed tomography (CE-CBCT), a technique capable of high-resolution in vivo imaging with small radiation dose, has been applied successfully for clinical diagnostics of cartilage degeneration, i.e., osteoarthritis (OA). As an X-ray technique, CE-CBCT may also detect changes in mineral density of subchondral bone (volumetric bone mineral density, vBMD), known to be characteristic for OA. However, its feasibility for density measurements is not clear due to limited signal-to-noise ratio and contrast of CBCT images. In the present study, we created clinically applicable hydroxyapatite phantoms and determined vBMDs of cortical bone, trabecular bone, subchondral trabecular bone and subchondral plate of 10 cadaver (ex vivo) and 10 volunteer (in vivo) distal femora using a clinical CBCT scanner, and for reference, also using a conventional CT scanner. Our results indicated strong linear correlations between the vBMD values measured with the CT and CBCT scanners , however, absolute vBMD values were dependent on the scanner in use. Further, the differences between the vBMDs of cortical bone, trabecular bone and subchondral bone were similar and independent of the scanner. The present results indicate that vBMD values might not be directly comparable between different instruments. However, based on our present and previous results, we propose that, for OA diagnostics, clinical CBCT enables not only quantitative analysis of articular cartilage but also subchondral bone vBMD. Quantitative information on both cartilage and subchondral bone could be beneficial in OA diagnostics.

Entities:  

Mesh:

Year:  2015        PMID: 25935027     DOI: 10.1109/TMI.2015.2426684

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  The role of cone beam CT in the study of symptomatic total knee arthroplasty (TKA): a 20 cases report.

Authors:  Cosimo Nardi; Roberto Buzzi; Roberto Molteni; Carlo Cossi; Chiara Lorini; Linda Calistri; Stefano Colagrande
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

2.  Multiparametric 3-D analysis of bone and joint space width at the knee from weight bearing computed tomography.

Authors:  Tom D Turmezei; Samantha B Low; Simon Rupret; Graham M Treece; Andrew H Gee; James W MacKay; John A Lynch; Kenneth Es Poole; Neil A Segal
Journal:  Osteoarthr Imaging       Date:  2022-06-17

3.  Quantitative Evaluation of the Mechanical Risks Caused by Focal Cartilage Defects in the Knee.

Authors:  Mikko S Venäläinen; Mika E Mononen; Jari Salo; Lasse P Räsänen; Jukka S Jurvelin; Juha Töyräs; Tuomas Virén; Rami K Korhonen
Journal:  Sci Rep       Date:  2016-11-29       Impact factor: 4.379

4.  Triple Contrast CT Method Enables Simultaneous Evaluation of Articular Cartilage Composition and Segmentation.

Authors:  Miitu K M Honkanen; Annina E A Saukko; Mikael J Turunen; Wujun Xu; Goran Lovric; Juuso T J Honkanen; Mark W Grinstaff; Vesa-Pekka Lehto; Juha Töyräs
Journal:  Ann Biomed Eng       Date:  2019-10-01       Impact factor: 3.934

5.  Preliminary Study on Immediate Postoperative CT Images and Values of the Modular Polyetheretherketone Based Total Knee Arthroplasty: An Observational First-in-Human Trial.

Authors:  Zhengyu Cai; Xinhua Qu; Yaochao Zhao; Zhiguo Yuan; Liangjun Zheng; Teng Long; Qiuying Yao; Bing Yue; You Wang
Journal:  Front Surg       Date:  2022-02-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.