Literature DB >> 25934658

Ophthalmic artery occlusion immediately following placement of a flow diverter without clinical sequelae.

Justin R Mascitelli1, Margaret Pain1, Fedor Panov1, Joshua B Bederson1, Aman B Patel2.   

Abstract

Branch vessel occlusion is a potential consequence following flow diverter placement for intracranial aneurysms, but the frequency and clinical impact has not been completely elucidated. In this case of a 45-year-old woman with a large left internal carotid artery aneurysm, the ophthalmic artery was covered by two flow diverters and was acutely occluded along with the aneurysm. Common carotid injections failed to demonstrate collateral flow to the ophthalmic artery via the external carotid artery. Nonetheless, the patient woke from anesthesia with objectively stable and subjectively improved vision. This case demonstrates that an acute occlusion of the ophthalmic artery without external carotid artery collaterals can be tolerated clinically.
© The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Intracranial aneurysm; flow diversion; ophthalmic artery

Mesh:

Year:  2015        PMID: 25934658      PMCID: PMC4757244          DOI: 10.1177/1591019915583217

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  14 in total

Review 1.  A review of central retinal artery occlusion: clinical presentation and management.

Authors:  D D Varma; S Cugati; A W Lee; C S Chen
Journal:  Eye (Lond)       Date:  2013-03-08       Impact factor: 3.775

2.  Endovascular treatment of intracranial aneurysms with flow-diverter stents: preliminary single-centre experience.

Authors:  Emanuele Malatesta; Nunzio Paolo Nuzzi; Ignazio Divenuto; Rita Fossaceca; Mariangela Lombardi; Paolo Cerini; Giuseppe Guzzardi; Alessandro Stecco; Cosma Andreula; Alessandro Carriero
Journal:  Radiol Med       Date:  2013-06-26       Impact factor: 3.469

3.  Orbital vascular anatomy and embryology.

Authors:  J Vignaud; A N Hasso; P Lasjaunias; C Clay
Journal:  Radiology       Date:  1974-06       Impact factor: 11.105

4.  Treatment of ophthalmic segment carotid aneurysms using the pipeline embolization device: clinical and angiographic follow-up.

Authors:  Karam Moon; Felipe C Albuquerque; Andrew F Ducruet; R Webster Crowley; Cameron G McDougall
Journal:  Neurol Res       Date:  2014-02-11       Impact factor: 2.448

5.  Pipeline embolization device: a new source for embolic retinal vascular occlusion.

Authors:  Adam B Sise; James M Osher; Martin P Kolsky; Andrew Stemer; William O Bank; Richard A Garfinkel
Journal:  J Neuroophthalmol       Date:  2013-12       Impact factor: 3.042

6.  The angiographic ocular choroidal crescent: distortion with intraorbital and remote intracranial pathology.

Authors:  A G Osborn; D J Thurman; H J Van Dyk
Journal:  Neuroradiology       Date:  1978-03-29       Impact factor: 2.804

7.  Acute branch occlusion after Pipeline embolization of intracranial aneurysms.

Authors:  Rishi R Lall; Emanuela Crobeddu; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  J Clin Neurosci       Date:  2013-08-11       Impact factor: 1.961

8.  The pipeline embolization device for the intracranial treatment of aneurysms trial.

Authors:  P K Nelson; P Lylyk; I Szikora; S G Wetzel; I Wanke; D Fiorella
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-09       Impact factor: 3.825

9.  Patency of the ophthalmic artery after flow diversion treatment of paraclinoid aneurysms.

Authors:  Ross C Puffer; David F Kallmes; Harry J Cloft; Giuseppe Lanzino
Journal:  J Neurosurg       Date:  2012-01-06       Impact factor: 5.115

10.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

View more
  2 in total

1.  Metal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check.

Authors:  Liang-Der Jou; Gouthami Chintalapani; Michel E Mawad
Journal:  Interv Neuroradiol       Date:  2015-11-30       Impact factor: 1.610

2.  Hemodynamic impacts of flow diverter devices on the ophthalmic artery.

Authors:  Xinzhi Wu; Zhongbin Tian; Jian Liu; Wenqiang Li; Junfan Chen; Yangyang Zhou; Xinjian Yang; Shiqing Mu
Journal:  J Transl Med       Date:  2019-05-16       Impact factor: 5.531

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.