Comparison between experimental and computational methods for the acoustic and thermal characterization of therapeutic ultrasound fields.

Subha Maruvada1, Yunbo Liu1, Joshua E Soneson1, Bruce A Herman1, Gerald R Harris1.   

Abstract

For high intensity therapeutic ultrasound (HITU) devices, pre-clinical testing can include measurement of power, pressure/intensity and temperature distribution, acoustic and thermal simulations, and assessment of targeting accuracy and treatment monitoring. Relevant International Electrotechnical Commission documents recently have been published. However, technical challenges remain because of the often focused, large amplitude pressure fields encountered. Measurement and modeling issues include using hydrophones and radiation force balances at HITU power levels, validation of simulation models, and tissue-mimicking material (TMM) development for temperature measurements. To better understand these issues, a comparison study was undertaken between simulations and measurements of the HITU acoustic field distribution in water and TMM and temperature rise in TMM. For the specific conditions of this study, the following results were obtained. In water, the simulated values for p+ and p- were 3% lower and 10% higher, respectively, than those measured by hydrophone. In TMM, the simulated values for p+ and p- were 2% and 10% higher than those measured by hydrophone, respectively. The simulated spatial-peak temporal-average intensity values in water and TMM were greater than those obtained by hydrophone by 3%. Simulated and measured end-of-sonication temperatures agreed to within their respective uncertainties (coefficients of variation of approximately 20% and 10%, respectively).

Entities:  

Year:  2015        PMID: 25920823     DOI: 10.1121/1.4916280

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  5 in total

1.  Effect of Frequency-Dependent Attenuation on Predicted Histotripsy Waveforms in Tissue-Mimicking Phantoms.

Authors:  Kenneth B Bader; Michael J Crowe; Jason L Raymond; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2016-04-20       Impact factor: 2.998

2.  Predicting the growth of nanoscale nuclei by histotripsy pulses.

Authors:  Kenneth B Bader; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-03-17       Impact factor: 3.609

3.  Broadband characterization of plastic and high intensity therapeutic ultrasound phantoms using time delay spectrometry-With validation using Kramers-Kronig relations.

Authors:  Subha Maruvada; Yunbo Liu; Paul Gammell; Keith Wear
Journal:  J Acoust Soc Am       Date:  2018-06       Impact factor: 1.840

4.  Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms.

Authors:  Sara L Johnson; Douglas A Christensen; Christopher R Dillon; Allison Payne
Journal:  Int J Hyperthermia       Date:  2018-10-15       Impact factor: 3.914

5.  Quantifying cell death induced by doxorubicin, hyperthermia or HIFU ablation with flow cytometry.

Authors:  Paul Christopher Lyon; Visa Suomi; Philip Jakeman; Leticia Campo; Constantin Coussios; Robert Carlisle
Journal:  Sci Rep       Date:  2021-02-23       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.