| Literature DB >> 25907994 |
Claude Pichonnaz1,2, Jean-Philippe Bassin3, Estelle Lécureux4, Damien Currat5, Brigitte M Jolles6.
Abstract
BACKGROUND: The evaluation of swelling is important for the outcome of total knee arthroplasty (TKA) surgery. The circumference or volume measurements are applicable at the bedside of the patient but are altered by muscular atrophy and the post-surgical dressing. Bioimpedance spectroscopy might overcome these limitations; however, it should be validated. This study aimed to explore the validity, the reliability and the responsiveness of bioimpedance spectroscopy for measuring swelling after TKA.Entities:
Mesh:
Year: 2015 PMID: 25907994 PMCID: PMC4422299 DOI: 10.1186/s12891-015-0559-5
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Patients’ characteristics
|
| |||||
|---|---|---|---|---|---|
|
|
|
|
|
|
|
| 69.5 (9.7) | 85.0 (14.3) | 167.9 (4.8) | 30.7 (4.8) | 12 (50) | 15 (62) |
Legends = BMI: Body Mass Index; SD = Standard Deviation.
Comparison of the measured swelling according to the measurement method
|
| |||
|---|---|---|---|
|
|
|
| |
|
| 3.0 (5.1) | 2.6 (4.1) | 3.5 (5.9) |
|
| 14.7 (9.5)* | 11.1 (5.7)* | 29.9 (9.8)* |
|
| 14.9 (8.2) | 11.7 (4.1) | 38.27 (7.8)† |
*Significant difference with baseline P < 0.01.
†Significant difference with day 2 P < 0.01.
Legends = BIS R0: Bioimpedance spectroscopy; SD: Standard Deviation.
Figure 1Comparison of swelling evolution according to the measurement method. Legend: black line: mean BIS R0, red’ line: mean volume, blue line: mean knee circumference, bars: standard deviation.
Intra- and inter- evaluator intraclass coefficient of correlation for BIS R0
|
| |||
|---|---|---|---|
|
|
|
| |
|
| 0.90; 0.93 | 0.99; 0.96 | 0.98; 0.98 |
|
| 0.89; 0.97 | 0.98; 0.98 | 0.97; 0.99 |
All ICC are significant at P < 0.01.
Legends = BIS R0: Bioimpedance spectroscopy; ICC: Intra-class Correlation Coefficient; 1st: first; 2nd: second.
Correlation between the measurement methods
|
| |||
|---|---|---|---|
|
|
|
| |
|
| 0.73* | 0.75* | 0.84* |
|
| 0.71* | 0.56* | 0.67* |
|
| 0.62* | 0.57* | 0.63* |
|
| 0.33 NS | 0.39 NS | 0.68* |
*Significant at P < 0.01; NS non-significant.
Legends = BIS R0: Bioimpedance spectroscopy; D2: two days after total knee arthroplasty; D8: eight days after total knee arthroplasty.
Comparison of the diagnostic power of the measurement methods
|
| |||||
|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
| 0.99* [0.98 - 1.00] | 13.4 | 0.96 | 0.96 |
|
| 0.84* [0.72 - 0.96] | 6.1 | 0.83 | 0.79 | |
|
| 0.91* [0.81 - 1.00] | 5.6 | 0.92 | 0.83 | |
|
|
| 1.00* [0.99 - 1.00] | 13.8 | 1 | 0.96 |
|
| 0.92* [0.84 - 1.00] | 7.7 | 0.92 | 0.92 | |
|
| 0.95* [0.90 - 1.00] | 5.8 | 0.96 | 0.88 | |
Legends = AUC: area under the curve; [95% IC]: 95% confidence interval; *: P < 0.01; BIS R0: Bioimpedance spectroscopy.