Literature DB >> 25902100

Comparing Short-Duration Electro-Oculograms with and without Mydriasis in Healthy Subjects.

C Türksever1, S Orgül1, M G Todorova1.   

Abstract

BACKGROUND: In order to obtain artifact-free electro-oculogram recordings the subject's cooperation is necessary. The aim of our study is to evaluate the recording characteristics of short-duration EOG and to compare the effect of mydriasis on electro-oculogram recordings in a cohort of controls. PATIENTS AND METHODS: Electro-oculogram recordings were performed on a light-emitting diode stimulus screen using a RETI-port gamma plus2 system (RETIscan™, Roland Consult). Fast oscillations were set at 1.5 sec (6 cycles; total duration 75 sec).The dark phase included: pre-adaptation (6 min), alternate fixation (4 min), fixation-rest (20 sec), 100 sweeps. The light phase included: light adaptation (4 min), alternate fixation (10 min), fixation-rest (20 sec), 250 sweeps. The amplifier band pass was filtered at 0.1÷50 Hz. The background illumination in mydriasis was 100 cd/m2 and in miosis--450 cd/m2.
RESULTS: A total of 55 controls participated and were divided into three age groups [number; mean (years, y); ±SD]: group 1: 18-20 years (19; 19.49 years; ±0.89); group 2: 20-40 years (18; 27.91 years; ±5.39) and group 3: 40-60 years (18; 48.66 years; ±4.00). The Arden ratio, dark-trough and light-peak did not differ between recordings with or without mydriasis (p=0.914; p=0.880; p=0.680, linear mixed-effects model). The age did not influence the Arden ratio, dark-trough, light-peak (p=0.206; p=0.112; p=0.155). Arden ratio, dark-trough, light-peak were comparable between tested eyes (p=0.934; p=0.193; p=0.270).
CONCLUSIONS: Short-duration electro-oculograms allow successful recording, furthermore, the application of mydriasis does not influence the quality of the recording. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25902100     DOI: 10.1055/s-0034-1396330

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  4 in total

1.  Preserved functional and structural integrity of the papillomacular area correlates with better visual acuity in retinitis pigmentosa.

Authors:  K Konieczka; R I Bojinova; C Valmaggia; D F Schorderet; M G Todorova
Journal:  Eye (Lond)       Date:  2016-08-05       Impact factor: 3.775

Review 2.  A meta-analysis of clinical electro-oculography values.

Authors:  Paul A Constable; David Ngo; Stephen Quinn; Dorothy A Thompson
Journal:  Doc Ophthalmol       Date:  2017-10-10       Impact factor: 2.379

3.  Is white the right light for the clinical electrooculogram?

Authors:  Paul A Constable; Garima Kapoor
Journal:  Doc Ophthalmol       Date:  2021-06-23       Impact factor: 2.379

4.  Electro-oculography in bilateral optic neuropathy.

Authors:  Padmini Dahanayake; Tharaka L Dassanayake; Manoji Pathirage; Saman Senanayake; Mike Sedgwick; Vajira Weerasinghe
Journal:  BMC Res Notes       Date:  2020-06-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.