Abstract

OBJECTIVE: Safe and cost-effective rotator-cuff repair. INDICATION: All types of rotator cuff lesions. CONTRAINDICATIONS: Frozen shoulder, rotator cuff mass defect, defect arthropathy. SURGICAL TECHNIQUE: Extensive four-point fixation on the bony footprint is performed using the double-row lateral augmentation screw anchor (LASA-DR) with high biomechanical stability. Following mobilization of the tendons, these are refixed in the desired configuration first medially and then laterally. To this end, two drilling channels (footprint and lateral tubercle) are created for each screw. Using the shuttle technique, a suture anchor screw is reinforced with up to four pairs of threads. The medial row is then pierced and tied, and the sutures that have been left long are tied laterally around the screw heads (double row). POSTOPERATIVE MANAGEMENT: 4 Weeks abduction pillow, resulting in passive physiotherapy, followed by initiation of active assisted physiotherapy. Full weight-bearing after 4-6 months.
RESULTS: Prospective analysis of 35 consecutive Bateman-III lesions with excellent results and low rerupture rate (6%).

Entities:  

Keywords:  Bone screws; Double-row; Open repair; Rotator cuff; Shoulder

Mesh:

Year:  2015        PMID: 25900829     DOI: 10.1007/s00064-014-0356-6

Source DB:  PubMed          Journal:  Oper Orthop Traumatol        ISSN: 0934-6694            Impact factor:   1.154


  5 in total

Review 1.  [Current operative strategies for rotator cuff tears in German hospitals].

Authors:  C Lüring; O Diedrich; F X Köck; J Grifka; M Tingart
Journal:  Orthopade       Date:  2007-09       Impact factor: 1.087

2.  Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair.

Authors:  Joshua B Frank; Neal S ElAttrache; Joshua S Dines; Allie Blackburn; John Crues; James E Tibone
Journal:  Am J Sports Med       Date:  2008-08       Impact factor: 6.202

3.  A novel transosseous button technique for rotator cuff repair.

Authors:  Michael P Fox; Alexander Auffarth; Mark Tauber; Andreas Hartmann; Herbert Resch
Journal:  Arthroscopy       Date:  2008-04-21       Impact factor: 4.772

4.  [Development of a questionnaire based on the Constant-Murley-Score for self-evaluation of shoulder function by patients].

Authors:  D Boehm; N Wollmerstedt; M Doesch; M Handwerker; E Mehling; F Gohlke
Journal:  Unfallchirurg       Date:  2004-05       Impact factor: 1.000

5.  Tendon-bone contact pressure and biomechanical evaluation of a modified suture-bridge technique for rotator cuff repair.

Authors:  Mike H Baums; Michael Geyer; Meike Büschken; Gottfried H Buchhorn; Gunter Spahn; Hans-Michael Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-14       Impact factor: 4.342

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.