Literature DB >> 25900623

Effect of Opalescence® bleaching gels on the elution of dental composite components.

Lena Schuster1, Lena Rothmund1, Xiuli He1, Kirsten L Van Landuyt2, Helmut Schweikl3, Elmar Hellwig4, Thomas Carell5, Reinhard Hickel6, Franz-Xaver Reichl1, Christof Högg7.   

Abstract

OBJECTIVES: Bleaching treatments can affect on the polymer network of dental composites. This study was performed to evaluate the influence of different bleaching treatments on the elution of composite components.
METHODS: The composites Tetric EvoCeram(®), CLEARFIL™ AP-X, Tetric EvoFlow(®), Filtek™ Supreme XT, Ceram X(®) mono+, Admira and Filtek™ Silorane were treated with the bleaching gels Opalescence PF 15% (PF 15%) for 5h and PF 35% (PF 35%) for 30 min and then stored in methanol and water for 24h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). Unbleached specimens were used as control group.
RESULTS: A total of 16 different elutable substances have been identified from the investigated composites after bleaching-treatment. Six of them were methacrylates: 1,10-decandioldimethacrylate (DDDMA), 1,12-dodekandioldimethacrylate (DODDMA), ethylenglycoldimethacrylate (EGDMA), 2-hydroxyethylmethacrylate (HEMA), triethylenglycoldimethacrylate (TEGDMA) and urethandimethacrylate (UDMA). Compared with the unbleached controls the composites Tetric EvoCeram(®), CLEARFIL™ AP-X and Tetric EvoFlow(®) showed a reduced elution of UDMA, TEGDMA and HEMA after bleaching-treatment. Compared with the unbleached controls an increase elution of UDMA, DMABEE, BPA and TEGDMA for the composites Filtek™ Supreme XT, Ceram X(®) mono+, Admira and Filtek™ Silorane after bleaching-treatment has been detected. The highest concentration of UDMA was 0.01 mmol/l (Tetric EvoCeram(®), water, 24h, controls), the highest concentration of TEGDMA was 0.28 mmol/l (CLEARFIL™ AP-X, water, 7 d, controls), the highest concentration of HEMA was 0.74 mmol/l (Tetric EvoFlow(®), methanol, 7 d, PF 35%), the highest concentration of DMABEE was 0.10 mmol/l (Ceram X(®) mono+, water, 7 d, PF 35%) and the highest concentration of BPA was 0.01 mmol/l (Admira, methanol, 7 d, controls). SIGNIFICANCE: Bleaching treatments can lead to a reduced or an increased elution of substances from the dental composites.
Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bleaching; Comonomer; Dental composite; Elution; Peroxide; Polymer network

Mesh:

Substances:

Year:  2015        PMID: 25900623     DOI: 10.1016/j.dental.2015.03.016

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  5 in total

1.  Effect of various light curing times on the elution of composite components.

Authors:  Christof Högg; Moritz Maier; Katherina Dettinger-Maier; Xiuli He; Lena Rothmund; Kai Kehe; Reinhard Hickel; Franz-Xaver Reichl
Journal:  Clin Oral Investig       Date:  2015-12-28       Impact factor: 3.573

2.  Effect of Adhesive Resin as a Modeling Liquid on Elution of Resin Composite Restorations.

Authors:  Mohammadreza Maalekipour; Mehri Safari; Mehrdad Barekatain; Amirhossein Fathi
Journal:  Int J Dent       Date:  2021-12-28

3.  Cutinase ACut2 from Blastobotrysraffinosifermentans for the Selective Desymmetrization of the Symmetric Diester Diethyl Adipate to the Monoester Monoethyl Adipate.

Authors:  Marion Rauter; Daniela Nietz; Gotthard Kunze
Journal:  Microorganisms       Date:  2022-06-29

Review 4.  Meta-analytical analysis on components released from resin-based dental materials.

Authors:  Francesco De Angelis; Nela Sarteur; Michal Šteffl; Camillo D'Arcangelo; Matteo Buonvivere; Mirco Vadini
Journal:  Clin Oral Investig       Date:  2022-07-23       Impact factor: 3.606

5.  Adhesion of human gingival fibroblasts/Streptococcus mitis co-culture on the nanocomposite system Chitlac-nAg.

Authors:  Amelia Cataldi; Marialucia Gallorini; Mara Di Giulio; Simone Guarnieri; Maria Addolorata Mariggiò; Tonino Traini; Roberta Di Pietro; Luigina Cellini; Eleonora Marsich; Silvia Sancilio
Journal:  J Mater Sci Mater Med       Date:  2016-03-12       Impact factor: 3.896

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.