Dosimetric study of mandible examinations performed with three cone-beam computed tomography scanners.

Helen J Khoury1, Marcos E Andrade2, Max Well Araujo2, Izabela V Brasileiro2, Richard Kramer2, Amir Huda3.   

Abstract

The objective of this work was to evaluate the air kerma-area product (PKA) and the skin absorbed dose in the region of the eyes, salivary glands and thyroid of the patient from mandible examinations performed with three cone-beam computed tomography (CBCT) scanners, i.e. i-CAT classic, Gendex CB-500 and PreXion 3D. For the dosimetric evaluation, an anthropomorphic head phantom (model RS-250) was used to simulate an adult patient. The CBCT examinations were performed using standard and high-resolution protocols for mandible acquisitions for adult patients. During the phantom's exposure, the PKA was measured using an ionising chamber and the absorbed doses to the skin in the region of the eyes, thyroid and salivary glands were estimated using thermoluminescence dosemeters (TLDs) positioned on the phantom's surface. The PKA values estimated with the CBCT scanners varied from 26 to 138 µGy m(2). Skin absorbed doses in the region of the eyes varied from 0.07 to 0.34 mGy; at the parotid glands, from 1.31 to 5.93 mGy; at the submandibular glands, from 1.41 to 6.86 mGy; and at the thyroid, from 0.18 to 2.45 mGy. PKA and absorbed doses showed the highest values for the PreXion 3D scanner due to the use of the continuous exposure mode and a high current-time product.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 25897144     DOI: 10.1093/rpd/ncv058

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures.

Authors:  Aline Pf Caetano; Thiago O Sousa; Mariana R Oliveira; Karine Evanglista; Juliano M Bueno; Maria Ag Silva
Journal:  Dentomaxillofac Radiol       Date:  2020-12-01       Impact factor: 2.419

2.  Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography.

Authors:  Nathália Cristine da Silva; Maurício Barriviera; José Luiz Cintra Junqueira; Francine Kühl Panzarella; Ricardo Raitz
Journal:  Imaging Sci Dent       Date:  2017-03-21

3.  Tissue Engineering and Dental Implantology: Biomaterials, New Technologies, and Stem Cells.

Authors:  Gilberto Sammartino; David M Dohan Ehrenfest; Jamil A Shibli; Pablo Galindo-Moreno
Journal:  Biomed Res Int       Date:  2016-03-17       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.