Impact of Pulsatility and Flow Rates on Hemodynamic Energy Transmission in an Adult Extracorporeal Life Support System.

Rachel Wolfe1, Ashton Strother1, Shigang Wang1, Allen R Kunselman2, Akif Ündar1,3.   

Abstract

This study investigated the total hemodynamic energy (THE) and surplus hemodynamic energy transmission (SHE) of a novel adult extracorporeal life support (ECLS) system with nonpulsatile and pulsatile settings and varying pulsatility to define the most effective setting for this circuit. The circuit consisted of an i-cor diagonal pump (Xenios AG, Heilbronn, Germany), an XLung membrane oxygenator (Xenios AG), an 18 Fr Medos femoral arterial cannula (Xenios AG), a 23/25 Fr Estech RAP femoral venous cannula (San Ramon, CA, USA), 3/8 in ID × 140 cm arterial tubing, and 3/8 in ID × 160 cm venous tubing. Priming was done with lactated Ringer's solution and packed red blood cells (HCT 36%). The trials were conducted at flow rates 1-4 L/min (1 L/min increments) under nonpulsatile and pulsatile mode, with differential speed values 1000-4000 rpm (1000 rpm increments) at 36°. The pseudo patient's mean arterial pressure was kept at 100 mm Hg using a Hoffman clamp during all trials. Real-time flow and pressure data were collected using a custom-based data acquisition system. Mean pressures across the circuit increased with increasing flow rates, but increased insignificantly with increasing differential speed values. Mean pressure did not change significantly between pulsatile and nonpulsatile modes. Pulsatile flow created more THE than nonpulsatile flow at the preoxygenator site (P < 0.01). Of the different components of the circuit, the arterial cannula created the greatest THE loss. THE loss across the circuit ranged from 24.8 to 71.3%. Still, under pulsatile mode, more THE was delivered to the pseudo patient at low flow rates. No SHE was created with nonpulsatile flow, but SHE was created with pulsatile flow, and increased with increasing differential speed values. At lower flow rates (1-2 L/min), the arterial cannula contributed the most to SHE loss, but at higher flow rates the arterial tubing created the most SHE loss. The circuit pressure drop values across all flow rates were 33.1-246.5 mm Hg, and were slightly higher under pulsatile mode than nonpulsatile mode. The i-cor diagonal pump creates satisfactory pulsatile and nonpulsatile flows, and can easily change the pulsatile amplitude and energy transmission. The attributes of the XLung membrane oxygenator include low resistance, low energy loss, and low pressure drops at all flow rates and differential speed values. The arterial cannula created the highest pressure drop of all components of the circuit. Pulsatile flow improved the transmission of hemodynamic energy to the pseudo patient without significantly affecting the pressure drops across the circuit.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Adult; Diagonal pump; Extracorporeal life support; Pulsatile flow; XLung membrane oxygenator

Mesh:

Year:  2015        PMID: 25894993     DOI: 10.1111/aor.12484

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

Review 1.  [Importance of mechanical assist devices in acute circulatory arrest].

Authors:  Markus Wolfgang Ferrari
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-02-10

2.  Electrocardiogram-synchronized pulsatile extracorporeal life support preserves left ventricular function and coronary flow in a porcine model of cardiogenic shock.

Authors:  Petr Ostadal; Mikulas Mlcek; Holger Gorhan; Ivo Simundic; Svitlana Strunina; Matej Hrachovina; Andreas Krüger; Dagmar Vondrakova; Marek Janotka; Pavel Hala; Martin Mates; Martin Ostadal; James C Leiter; Otomar Kittnar; Petr Neuzil
Journal:  PLoS One       Date:  2018-04-24       Impact factor: 3.240

Review 3.  Utilization of Percutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock Complicating Acute Myocardial Infarction and High-Risk Percutaneous Coronary Interventions.

Authors:  Rabea Asleh; Jon R Resar
Journal:  J Clin Med       Date:  2019-08-13       Impact factor: 4.241

4.  Development of a Pulsatile Flow-Generating Circulatory Assist Device (K-Beat) For Use with Veno-Arterial Extracorporeal Membrane Oxygenation in a Pig Model Study.

Authors:  Yutaka Fujii; Nobuo Akamatsu; Yasunori Yamasaki; Kota Miki; Masayuki Banno; Kenta Minami; Shuji Inamori
Journal:  Biology (Basel)       Date:  2020-06-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.