Literature DB >> 25883868

The validity and reliability of a new instrumented device for measuring ankle dorsiflexion range of motion.

Joaquin Calatayud1, Fernando Martin1, Pedro Gargallo1, Jessica García-Redondo2, Juan Carlos Colado1, Pedro J Marín3.   

Abstract

PURPOSE/
BACKGROUND: A restriction in ankle dorsiflexion range of motion (ROM) has been linked to several clinical manifestations such as metatarsalgia, heel pain, nerve entrapment, ankle joint equinus, patellar and ankle injuries. The purpose of the present study was to examine the validity and reliability of the Leg Motion system for measuring ankle dorsiflexion ROM. STUDY
DESIGN: Descriptive repeated-measures study.
METHODS: Twenty-six healthy male university students were recruited to test the reliability of the Leg Motion system, which is a portable tool used for assessment of ankle dorsiflexion during the weight-bearing lunge test. The participants were tested two times separated by two weeks and measurements were performed at the same time of the day by the same single rater. To test the validity of the Leg Motion system, other maximal ankle dorsiflexion ROM assessments (goniometer, inclinometer and measuring tape) were measured in a single session (i.e., the first test session) during the weight-bearing lunge position using a standard goniometer, a digital inclinometer and a measuring tape measure with the ability to measure to the nearest 0.1 cm.
RESULTS: Paired t-tests showed the absence of significant differences between right and left limb measurements of dorsiflexion in all tests. Mean values ± standard deviations were as follows: Leg Motion test (left 11.6cm±3.9; right 11.9cm ±4.0), tape measure (left 11.6cm±4.0; right 11.8cm±4.2), goniometer (left 40.6º±5.2; right 40.6º±5.2), and digital inclinometer (left 40.0º±5.8; right 39.9º±5.6). The Leg Motion composite values (i.e., average of the two legs) showed a significant (p<0.05) positive correlation with the tape measure (r=0.99), with the goniometer (r=0.66), and with the digital inclinometer (r=0.72).
CONCLUSIONS: The results of the present study provide evidence to support the use of the Leg Motion system as a valid, portable, and easy to use alternative to the weight-bearing lunge test to assess ankle dorsiflexion ROM in healthy participants. LEVEL OF EVIDENCE: 2b.

Entities:  

Keywords:  Ankle dorsiflexion; goniometer; inclinometer; weight‐bearing lunge

Year:  2015        PMID: 25883868      PMCID: PMC4387727     

Source DB:  PubMed          Journal:  Int J Sports Phys Ther        ISSN: 2159-2896


  17 in total

1.  Intra-rater and inter-rater reliability of a weight-bearing lunge measure of ankle dorsiflexion.

Authors:  Kim L Bennell; Richard C Talbot; Henry Wajswelner; Wassana Techovanich; David H Kelly; Andrew J Hall
Journal:  Aust J Physiother       Date:  1998

2.  A weightbearing technique for the measurement of ankle joint dorsiflexion with the knee extended is reliable.

Authors:  Shannon E Munteanu; Andrea B Strawhorn; Karl B Landorf; Adam R Bird; George S Murley
Journal:  J Sci Med Sport       Date:  2007-09-20       Impact factor: 4.319

3.  Motion measured from forefoot and hindfoot landmarks during passive ankle dorsiflexion range of motion.

Authors:  R W Bohannon; D Tiberio; G Waters
Journal:  J Orthop Sports Phys Ther       Date:  1991       Impact factor: 4.751

4.  The influence of ankle dorsiflexion and self-reported patient outcomes on dynamic postural control in participants with chronic ankle instability.

Authors:  Masafumi Terada; Matthew S Harkey; Ashley M Wells; Brian G Pietrosimone; Phillip A Gribble
Journal:  Gait Posture       Date:  2014-04-03       Impact factor: 2.840

Review 5.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

Review 6.  Clinical assessment of ankle joint dorsiflexion: a review of measurement techniques.

Authors:  Alfred Gatt; Nachiappan Chockalingam
Journal:  J Am Podiatr Med Assoc       Date:  2011 Jan-Feb

7.  A simplified version of the weight-bearing ankle lunge test: description and test-retest reliability.

Authors:  Antonio Cejudo; Pilar Sainz de Baranda; Francisco Ayala; Fernando Santonja
Journal:  Man Ther       Date:  2014-04-02

8.  Effect of limiting ankle-dorsiflexion range of motion on lower extremity kinematics and muscle-activation patterns during a squat.

Authors:  Elisabeth Macrum; David Robert Bell; Michelle Boling; Michael Lewek; Darin Padua
Journal:  J Sport Rehabil       Date:  2011-11-15       Impact factor: 1.931

9.  Lower extremity range of motion in the recreational sport runner.

Authors:  M Pink; J Perry; P A Houglum; D J Devine
Journal:  Am J Sports Med       Date:  1994 Jul-Aug       Impact factor: 6.202

10.  Reliability of health-related physical fitness tests in European adolescents. The HELENA Study.

Authors:  F B Ortega; E G Artero; J R Ruiz; G Vicente-Rodriguez; P Bergman; M Hagströmer; C Ottevaere; E Nagy; O Konsta; J P Rey-López; A Polito; S Dietrich; M Plada; L Béghin; Y Manios; M Sjöström; M J Castillo
Journal:  Int J Obes (Lond)       Date:  2008-11       Impact factor: 5.095

View more
  17 in total

1.  RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

Authors:  Oliver Gonzalo-Skok; Jorge Serna; Matthew R Rhea; Pedro J Marín
Journal:  Int J Sports Phys Ther       Date:  2015-10

2.  AGE DIFFERENCES IN MEASURES OF FUNCTIONAL MOVEMENT AND PERFORMANCE IN HIGHLY YOUTH BASKETBALL PLAYERS.

Authors:  Oliver Gonzalo-Skok; Jorge Serna; Matthew R Rhea; Pedro J Marín
Journal:  Int J Sports Phys Ther       Date:  2017-10

3.  The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults.

Authors:  Carlos Romero Morales; César Calvo Lobo; David Rodríguez Sanz; Irene Sanz Corbalán; Beatriz Ruiz Ruiz; Daniel López López
Journal:  PeerJ       Date:  2017-01-03       Impact factor: 2.984

4.  Associations between ankle dorsiflexion range of motion and foot and ankle strength in young adults.

Authors:  Paloma Guillén-Rogel; Cristina San Emeterio; Pedro J Marín
Journal:  J Phys Ther Sci       Date:  2017-08-10

5.  Cross transfer acute effects of foam rolling with vibration on ankle dorsiflexion range of motion.

Authors:  María Teresa García-Gutiérrez; Paloma Guillén-Rogel; Darryl J Cochrane; Pedro J Marín
Journal:  J Musculoskelet Neuronal Interact       Date:  2018-06-01       Impact factor: 2.041

6.  ACTN3 R577X Genotype and Exercise Phenotypes in Recreational Marathon Runners.

Authors:  Juan Del Coso; Victor Moreno; Jorge Gutiérrez-Hellín; Gabriel Baltazar-Martins; Carlos Ruíz-Moreno; Millán Aguilar-Navarro; Beatriz Lara; Alejandro Lucía
Journal:  Genes (Basel)       Date:  2019-05-29       Impact factor: 4.096

7.  Validity and Reliability of an Inertial Device for Measuring Dynamic Weight-Bearing Ankle Dorsiflexion.

Authors:  José M Oliva-Lozano; Isabel Martín-Fuentes; José M Muyor
Journal:  Sensors (Basel)       Date:  2020-01-10       Impact factor: 3.576

8.  A randomised cross over study to evaluate the performance of a novel ankle dorsiflexion measurement device for novice users.

Authors:  Peter R Worsley; Caitlan Conington; Holly Stuart; Alice Patterson; Dan L Bader
Journal:  J Foot Ankle Res       Date:  2018-07-31       Impact factor: 2.303

9.  Discrepancy between true ankle dorsiflexion and gait kinematics and its association with severity of planovalgus foot deformity.

Authors:  Ki Hyuk Sung; Chin Youb Chung; Kyoung Min Lee; Ki Bum Kwon; Jeong Hyun Lee; Moon Seok Park
Journal:  BMC Musculoskelet Disord       Date:  2020-04-16       Impact factor: 2.362

10.  Validity and Reliability of the WIMUTM Inertial Device for the Assessment of Joint Angulations.

Authors:  Javier García-Rubio; José Pino; Pedro R Olivares; Sergio J Ibáñez
Journal:  Int J Environ Res Public Health       Date:  2019-12-27       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.